Trane
RT-PRC031-EN
manual
Specifications
Install
Dimension
Supply Airflow Configuration
Supply Air Setpoint Reset
Selection Procedure
Performance Adjustment Factors
Zone Temperature Control
Weight
Unit Placement
Page 107
Page 106
Page 108
Image 107
Page 106
Page 108
Contents
IntelliPak II Air Handlers
Introduction
Table of Contents
Controls Cabinet Mechanical
Features and Benefits
Standard Features
Features and Benefits Optional Features
Reliability
Features and Benefits Field Installed Accessories
Features Summary
Installation and Service
Simplifying the Comfort System
Features and Benefits Application Flexibility
Integrated Comfort with Trane Tracer LCI
Optimum Building Comfort Control
Features and Benefits
Interoperability
Statitrac
Statitrac Direct Space Building Pressurization Control
Variable Frequency Drives VFD
Supply Fans with Inlet Guide Vanes
Supply Air Temperature Controls Supply Air Pressure Control
Controls Variable Air Volume VAV Only
Heating
Controls Variable Air Volume VAV Only
Supply Air Setpoint Reset
Zone Temperature Control
Gas Heating Two-Stage
Controls Constant Volume CV Only
Occupied Zone Temperature Control
Heating
Hot Water or Steam Heating
Controls Constant Volume CV Only Auto Changeover
Unoccupied Zone Temperature Control
Cooling and Heating
Emergency Override
Controls VAV and CV
Space Pressure Control Statitrac
Morning Warm-up Options
Ventilation Override Module VOM
Controls VAV and CV
Human Interface Panel Main Menu
Human Interface Panel HI
Generic Building Automation System Module Gbas 0-5 vdc
Night Setback Sensors
Generic Building Automation System Module Gbas 0-10 vdc
Chilled Water Coil Freeze Stat
Steam and Hot Water Coil Freeze Avoidance
Timed Override Activation
Dry Bulb Temperature Control of Economizer
Occupied/Unoccupied input on the RTM
Trane Tracer or BAS System
Twinning
Humidification Control
LonTalk Building Automation System
Return Fan Control
Advantages
Applications Considerations
Exhaust/Return Fan Options
Application Recommendations
Applications Considerations
Supply and Return Airflow Configurations
Cartridge
Supply Airflow Configuration
Return Airflow Configuration
With Bag
Acoustical Considerations
Corrosive Atmospheres
Ventilation Override Sequences
Natural Gas Heating Considerations
Clearance Requirements
Unit Placement
External Piping Enclosure
Duct Design
Protecting Hydronic Coils From Freezing
Selection Procedure
Selection Procedure
Altitude Corrections
Exhaust Fan Motor Sizing
Return Fan Motor Sizing
Unit Electrical Requirements
Digit 7 Chilled Water Coil FIN Series
Model Number Description
Digit 20 System Control Selection
Model Number Description
Digit 38 Belt Guards Burglar BARS/MARINE Lights
General Data
General Data All dimensions in inches
General Data
Standard Damper Optional Low Leak Damper
Gas Heat Inputs/Input Ranges
Economizer Outdoor Air Damper Leakage at rated airflowi
Inputs MBH Input MBH Range MBH
Gas Heating Capacity Altitude Correction Factors
Performance Adjustment Factors
Wet Bulb Temperature Btu per Pound
Enthalpy of Saturated Air
DB F WB F
Performance Data-Chilled Water Coil Capacities
Chilled Water Coil Capacities-2 Row 5W
Chilled Water Coil Capacities-4 Row W
Performance Data-Chilled Water Coil Capacities
Chilled Water Coil Capacities-6 Row WD
Chilled Water Coil Capacities-8 Row WD
Total Static Pressure Std Air
Supply Fan Performance Standard CFM Casing a
1644
Supply Fan w/o IGV
931
Supply Fan Performance Standard CFM -Casing B
1117
Supply Fan Performance Standard CFM-Casing B
749
Supply Fan Performance Standard CFM Casing C
1019
Std Air
Total Static Pressure
Performance Data Supply Fan with Inlet Guide Vanes
Performance Data Supply Fan with Inlet Guide Vanes
Supply Fan Performance Standard CFM-Casing a
Supply Fan Performance Standard CFM Casing B
1093
1600 RPM 1500 RPM
779
1021
1283
Negative Static Pressure Std Air
Performance Data-Exhaust Fan
Static PresureInWC
Performance Data-Exhaust Fan
237i
Wocfm
415
Exhaust Fan Performance Standard CFM-Case C 32 Fan
0 R P M
Return Fan Performance Standard CFM-Case a 36.5 Fan
Performance Data-Return Fan
Return Fan Performance
Performance Data-Return Fan
Return Fan Performance Standard CFM-Case B and Case C 40 Fan
Return Fan Performance
Electric Heat kw Ranges
Electric Heat Air Temperature Rise
Performance Data-Heat
Natural Gas Heating Capacities1
Properties of Steam
Performance Data-Heat
Hot Water Coil Heating Capacities Q/ITD
Steam Coil Heating Capacities Q/ITD
Component Static Pressure Drops in. H2O
Chilled Water Coil Airside Pressure Drop in H20
Filters Prefilter
High Low PD Cartridge Bag Filters
Cartridge Filters Throw Temp Hi Temp Away Prefilter Casing
Drive No
Supply Air Fan Drive Selections
15 HP 20 HP 25 HP 30 HP 40 HP Drive No
Horse Power HP Low Casing Std
Exhaust Air Fan Drive Selections
Return Air Fan Drive Selections
Set 2. Cooling with Electric Heat
Electrical Service Sizing
Electrical Data
Set 1. Cooling with Gas Heat Air Handling Units
Electrical Service Sizing Data-Motors
Nominal Tons Voltage 460 575 FLA Add 90-150
Electrical Data
Voltage Utilization Range
Unit Voltage
Unit Top/Front View
Dimensional Data
Return Exhaust Unit Height Fan Casing
Dimensional Data
Unit Dimensions In.-One-Piece Unit
Supply Opening Blank Casing Gas Heat Section
Downflow/Horizontal Airflow Configuration Dimensions
Opening
Electrical Entry Details
Piping
Chilled Water Piping Locations
Exh Box
Minimum Required Clearance
Unit Option Selection Door Swing Ft. Standard
Minimum Required Clearance Ft Control
Cross Member Location Blank Casing Section
Dimensions Blank Casing Section
Blank Casing Section
Field Installed Sensors Variable Air Volume VAV
Field Installed Sensors Constant Volume CV
Field Installed Sensors VAV and CV
Wireless Zone Sensor Wall or Duct Mount CO2 Zone Sensors
Component Weights Lbs
Weights
Approximate Operating Weights Lbs
Weights
Size Wt lbs Control Box Main 454 Convenience Outlet
Roof Curb Weights
Installed Shipping Casing Blank Weight
Options
Filters
Options
System Control
Fresh Air
Miscellaneous Options
Agency Approval
Electronic Zone Sensors
Field Installed Accessories
Roof Curb
Electrical System
Mechanical Specifications
General
Air Handling System
Mechanical Specifications Cooling System Chilled Water Coil
Water Valve
External Piping Enclosure
Mechanical Specifications Filters
Percent Modulating Exhaust Fan Option
Mechanical Specifications
Exhaust Air
No Relief Standard
Fresh Air
Mechanical Specifications Return Air
Heating System
CO2 Sensing
Page
RT-PRC031-EN