Trane RT-PRC031-EN manual Downflow/Horizontal Airflow Configuration Dimensions, Opening

Page 81

Dimensional Data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit Dimensions

Table 45 Downflow/Horizontal Airflow Configuration Dimensions (In.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DOWNFLOW Opening Dimensions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Return Opening—with or

 

 

Return Opening—with Return Fan

 

 

 

 

 

 

without Exhaust Fan

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Blank

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Casing

Gas Heat

Section

 

X1

Y1

 

 

W1

L1

 

X1

 

 

Y1

W1

L1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No Gas

None

 

14 13/16

8 14/16

 

48

3/16

121 15/16

14 13/16

 

42 14/16

48

3/16

53 14/16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No Gas

4Ft

 

14 13/16

8 14/16

 

48

3/16

121 15/16

14 13/16

 

42 14/16

48

3/16

53 14/16

A, B, C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No Gas

8Ft

 

14 13/16

8 14/16

 

48

3/16

121 15/16

14 13/16

 

42 14/16

48

3/16

53 14/16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas

None

 

14 13/16

8 14/16

 

48

3/16

121 15/16

14 13/16

 

42 14/16

48

3/16

53 14/16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas

8Ft

 

14 13/16

8 14/16

 

48

3/16

121 15/16

14 13/16

 

42 14/16

48

3/16

53 14/16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DOWNFLOW

Opening

Dimensions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Supply Opening

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Blank

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Casing

Gas Heat

Section

 

X2

Y2

 

 

W2

L2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No Gas

None

 

256

1/16

13

 

47 14/16

102

8/16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No Gas

4Ft

 

304

4/16

13

 

47 14/16

102

8/16

 

 

 

 

 

 

 

 

 

A, B, C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No Gas

8Ft

 

352

8/16

13

 

47 14/16

102

8/16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas

None

 

256

1/16

13

 

47 14/16

102

8/16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas

8Ft

 

352

8/16

13

 

47 14/16

102

8/16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HORIZONTAL

Opening Dimensions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Return Side Opening

 

 

 

 

Return End Opening

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Blank

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Casing

Gas Heat

Section

 

X3

Y3

 

 

W3

H1

 

X1

 

 

Y3

 

H3

H1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No Gas

None

 

9

5/16

10 10/16

 

54 12/16

84 15/16

6

5/16

 

8

3/16

35

3/16

127

2/16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No Gas

4Ft

 

9

5/16

10 10/16

 

54 12/16

84 15/16

6

5/16

 

8

3/16

35

3/16

127

2/16

A, B, C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No Gas

8Ft

 

9

5/16

10 10/16

 

54 12/16

84 15/16

6

5/16

 

8

3/16

35

3/16

127

2/16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas

None

 

9

5/16

10 10/16

 

54 12/16

84 15/16

6

5/16

 

8

3/16

35

3/16

127

2/16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas

8Ft

 

9

5/16

10 10/16

 

54 12/16

84 15/16

6

5/16

 

8

3/16

35

3/16

127

2/16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HORIZONTAL

Opening

Dimensions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Supply Opening

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Blank

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Casing

Gas Heat

Section

 

X4

Y4

 

 

W4

H2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No Gas

None

 

254 12/16

10 10/16

 

54 12/16

84 15/16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No Gas

4Ft

 

302 15/16

10 10/16

 

54 12/16

84 15/16

 

 

 

 

 

 

 

 

 

A, B, C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No Gas

8Ft

 

351

3/16

10 10/16

 

54 12/16

84 15/16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas

None

 

254 12/16

10 10/16

 

54 12/16

66 11/16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas

8Ft

 

351

3/16

10 10/16

 

54 12/16

84 15/16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RT-PRC031-EN

81

Image 81
Contents IntelliPak II Air Handlers Introduction Table of Contents Features and Benefits Standard FeaturesControls Cabinet Mechanical Features and Benefits Optional Features Features Summary Features and Benefits Field Installed AccessoriesInstallation and Service ReliabilityFeatures and Benefits Application Flexibility Integrated Comfort with Trane Tracer LCISimplifying the Comfort System Features and Benefits InteroperabilityOptimum Building Comfort Control Statitrac Statitrac Direct Space Building Pressurization ControlVariable Frequency Drives VFD Supply Fans with Inlet Guide VanesSupply Air Temperature Controls Supply Air Pressure Control Controls Variable Air Volume VAV OnlyControls Variable Air Volume VAV Only Supply Air Setpoint ResetHeating Zone Temperature Control Occupied Zone Temperature Control Controls Constant Volume CV OnlyHeating Gas Heating Two-StageUnoccupied Zone Temperature Control Controls Constant Volume CV Only Auto ChangeoverCooling and Heating Hot Water or Steam HeatingSpace Pressure Control Statitrac Controls VAV and CVMorning Warm-up Options Emergency OverrideVentilation Override Module VOM Controls VAV and CVHuman Interface Panel HI Generic Building Automation System Module Gbas 0-5 vdcHuman Interface Panel Main Menu Chilled Water Coil Freeze Stat Generic Building Automation System Module Gbas 0-10 vdcSteam and Hot Water Coil Freeze Avoidance Night Setback SensorsOccupied/Unoccupied input on the RTM Dry Bulb Temperature Control of EconomizerTrane Tracer or BAS System Timed Override ActivationLonTalk Building Automation System Humidification ControlReturn Fan Control TwinningExhaust/Return Fan Options Applications ConsiderationsApplication Recommendations AdvantagesApplications Considerations Supply and Return Airflow ConfigurationsReturn Airflow Configuration Supply Airflow ConfigurationWith Bag CartridgeVentilation Override Sequences Corrosive AtmospheresNatural Gas Heating Considerations Acoustical ConsiderationsClearance Requirements Unit PlacementDuct Design Protecting Hydronic Coils From FreezingExternal Piping Enclosure Selection Procedure Selection Procedure Return Fan Motor Sizing Exhaust Fan Motor SizingUnit Electrical Requirements Altitude CorrectionsDigit 7 Chilled Water Coil FIN Series Model Number DescriptionDigit 20 System Control Selection Model Number DescriptionDigit 38 Belt Guards Burglar BARS/MARINE Lights General Data General Data All dimensions in inchesGeneral Data Economizer Outdoor Air Damper Leakage at rated airflowi Gas Heat Inputs/Input RangesInputs MBH Input MBH Range MBH Standard Damper Optional Low Leak DamperWet Bulb Temperature Btu per Pound Performance Adjustment FactorsEnthalpy of Saturated Air Gas Heating Capacity Altitude Correction FactorsPerformance Data-Chilled Water Coil Capacities Chilled Water Coil Capacities-2 Row 5WDB F WB F Chilled Water Coil Capacities-4 Row W Performance Data-Chilled Water Coil CapacitiesChilled Water Coil Capacities-6 Row WD Chilled Water Coil Capacities-8 Row WD Total Static Pressure Std Air Supply Fan Performance Standard CFM Casing a1644 Supply Fan w/o IGV 931 Supply Fan Performance Standard CFM -Casing B1117 Supply Fan Performance Standard CFM-Casing B 749 Supply Fan Performance Standard CFM Casing C1019 Std Air Total Static PressurePerformance Data Supply Fan with Inlet Guide Vanes Performance Data Supply Fan with Inlet Guide Vanes Supply Fan Performance Standard CFM-Casing a Supply Fan Performance Standard CFM Casing B 1093 1600 RPM 1500 RPM 779 1021 1283 Negative Static Pressure Std Air Performance Data-Exhaust FanStatic PresureInWC Performance Data-Exhaust Fan237i Wocfm 415 Exhaust Fan Performance Standard CFM-Case C 32 Fan0 R P M Return Fan Performance Standard CFM-Case a 36.5 Fan Performance Data-Return FanReturn Fan Performance Performance Data-Return FanReturn Fan Performance Standard CFM-Case B and Case C 40 Fan Return Fan Performance Performance Data-Heat Electric Heat Air Temperature RiseNatural Gas Heating Capacities1 Electric Heat kw RangesHot Water Coil Heating Capacities Q/ITD Performance Data-HeatSteam Coil Heating Capacities Q/ITD Properties of SteamComponent Static Pressure Drops in. H2O Chilled Water Coil Airside Pressure Drop in H20High Low PD Cartridge Bag Filters Cartridge Filters Throw Temp Hi Temp Away Prefilter CasingFilters Prefilter Drive No Supply Air Fan Drive SelectionsExhaust Air Fan Drive Selections Horse Power HP Low Casing StdReturn Air Fan Drive Selections 15 HP 20 HP 25 HP 30 HP 40 HP Drive NoElectrical Data Electrical Service SizingSet 1. Cooling with Gas Heat Air Handling Units Set 2. Cooling with Electric HeatElectrical Service Sizing Data-Motors Voltage Utilization Range Electrical DataUnit Voltage Nominal Tons Voltage 460 575 FLA Add 90-150Unit Top/Front View Dimensional DataDimensional Data Unit Dimensions In.-One-Piece UnitReturn Exhaust Unit Height Fan Casing Downflow/Horizontal Airflow Configuration Dimensions OpeningSupply Opening Blank Casing Gas Heat Section Electrical Entry Details Piping Chilled Water Piping Locations Unit Option Selection Door Swing Ft. Standard Minimum Required ClearanceMinimum Required Clearance Ft Control Exh BoxDimensions Blank Casing Section Blank Casing SectionCross Member Location Blank Casing Section Field Installed Sensors Variable Air Volume VAV Field Installed Sensors Constant Volume CV Field Installed Sensors VAV and CV Wireless Zone Sensor Wall or Duct Mount CO2 Zone Sensors Weights Approximate Operating Weights LbsComponent Weights Lbs Weights Roof Curb Weights Installed Shipping Casing Blank WeightSize Wt lbs Control Box Main 454 Convenience Outlet Options Filters OptionsSystem Control Fresh AirMiscellaneous Options Agency ApprovalElectronic Zone Sensors Field Installed AccessoriesRoof Curb Mechanical Specifications GeneralElectrical System Water Valve Mechanical Specifications Cooling System Chilled Water CoilExternal Piping Enclosure Air Handling SystemMechanical Specifications Filters Exhaust Air Mechanical SpecificationsNo Relief Standard Percent Modulating Exhaust Fan OptionFresh Air Mechanical Specifications Return AirHeating System CO2 Sensing Page RT-PRC031-EN