Trane RT-PRC031-EN manual Model Number Description, Digit 20 System Control Selection

Page 32

Model Number Description

AReturn w/o Statitrac CV Only C Return w/ VFD w/ Bypass w/

Statitrac

E Return w/ VFD w/o Bypass w/ Statitrac

DIGIT 18 — EXHAUST/RETURN FAN MOTOR SELECTION

0None D 7.5 Hp E 10 Hp F 15 Hp G 20 Hp H 25 Hp J 30 Hp K 40 Hp L 50 Hp M 60 Hp

DIGIT 19 — EXHAUST/RETURN RPM SELECTION

0None

3300

4400

5500

6600

7700

8800

9900 A 1000 B 1100 C 1200 D 1300 E 1400

DIGIT 20 — SYSTEM CONTROL SELECTION

1Constant Volume (Zone Temperature Control)

2VAV w/o Inlet Guide Vanes (Discharge Air Control)

3VAV w/ Inlet Guide Vanes (Discharge Air Control)

4VFD Supply w/o Bypass (Discharge Air Control)

5VFD Supply w/Bypass (Discharge Air Control)

DIGIT 21 — FRESH AIR AND ECONOMIZER OPTIONS/ CONTROLS

A0 - 25 % Motorized Damper

BEcon w/Dry Bulb

CEcon w/Reference Enthalpy

DEcon w/Comparative Enthalpy

EEcon w/Fresh Air Measure /Dry Bulb

FEcon w/ Fresh Air Measure /Ref Enth

GEcon w/Fresh Air Measure /Comp Enth

HEcon w/DCV /Dry Bulb

JEcon w/DCV /Ref Enth

KEcon w/DCV /Comp Enth

DIGIT 22 — DAMPER OPTION

0Standard

1Low Leak

2Ultra Low Leak

DIGIT 23 — PRE COOLING COIL FILTER SELECTION

02" High Efficiency Throw Away

12" Throw Away Rack / Less Filters

290 - 95%, Bag Filters w/ Pre Filters

3Bag Filter Rack / Less Filters

490 - 95%, Cartridge Filters w/ Pre Filters

5Cartridge Rack / Less Filters

690 - 95% Low PD Cartridge w/ Pre Filters

7Low PD Cartridge Rack / Less Filters

DIGIT 24 — BLANK SECTION APPLICATION OPTIONS

0 None

A90 - 95% Bag w/Pre Filters

B90 - 95% Low PD Cartridge w/ Pre Filters

C90 - 95%, Cartridge Filters w/ Pre Filters

D90 - 95% Hi Temp Cartridge w/ Pre Filters

EHEPA w/Pre Filters

FHi Temp HEPA w/Pre Filters

DIGIT 25 — FUTURE

DEVELOPMENT

0

DIGIT 26 — UNIT MOUNTED POWER CONNECTION SELECTION

ATerminal Block

BNon Fused Disconnect

CNon Fused Disconnect w/ Pwrd conv outlet

DCircuit Breaker w/ SCWR

ECkt Brkr w/ SCWR/ Pwrd conv outlet

DIGIT 27 — (FUTURE

DEVELOPMENT)

0 None

DIGIT 28 — COIL/DRAIN PAN

DNo Drain Pan

EGalvanized Drain Pan

FCooling Coil - Galv DP

GCooling Coil - Stnls Steel DP

DIGIT 29 — CHILLED WATER COIL VALVE

0 None

A1.5" Cooling Valve

B2" Cooling Valve

C2.5" Cooling Valve

D3" Cooling Valve

DIGIT 30 — (FUTURE

DEVELOPMENT)

0 None

DIGIT 31 — (FUTURE

DEVELOPMENT)

0 None

DIGIT 32 — HIGH DUCT TEMPERATURE THERMOSTAT

0None

1High Duct Temp Thermostat

DIGIT 33 — REMOTE HUMAN INTERFACE

0None

1RHI & IPCB

2IPCB

DIGIT 34 — MODULE OPTIONS

0 None

A0-5 Volt GBAS

B0-10 Volt GBAS

C0-5 / 0-10 Volt GBAS

FLCI

DVentilation Override

G0-5 Volt GBAS / Ventilation Override

H0-10 Volt GBAS / Ventilation Override

J 0-5 / 0-10 V GBAS / Ventilation

Override

L LCI / Ventilation Override

DIGIT 35 — ZONE SENSOR OPTION

0 None

ADual Setpoint w/Man/Auto Changeover

BDual Stpt w/Man/Auto Chgovr & Sys Lights

CRoom Sensor w/Timed Override & Cancel

DRoom Snsr w/TO & Cancel & Local Stpt Adj

ECV Programmable Night Setback

FVAV Programmable Night Setback

GVAV w/System Lights

DIGIT 36 — AGENCY APPROVAL OPTION

0None

1UL/CSA

32

RT-PRC031-EN

Image 32
Contents IntelliPak II Air Handlers Introduction Table of Contents Controls Cabinet Mechanical Features and BenefitsStandard Features Features and Benefits Optional Features Features and Benefits Field Installed Accessories Features SummaryInstallation and Service ReliabilitySimplifying the Comfort System Features and Benefits Application FlexibilityIntegrated Comfort with Trane Tracer LCI Optimum Building Comfort Control Features and BenefitsInteroperability Statitrac Direct Space Building Pressurization Control StatitracSupply Fans with Inlet Guide Vanes Variable Frequency Drives VFDControls Variable Air Volume VAV Only Supply Air Temperature Controls Supply Air Pressure ControlHeating Controls Variable Air Volume VAV OnlySupply Air Setpoint Reset Zone Temperature Control Controls Constant Volume CV Only Occupied Zone Temperature ControlHeating Gas Heating Two-StageControls Constant Volume CV Only Auto Changeover Unoccupied Zone Temperature ControlCooling and Heating Hot Water or Steam HeatingControls VAV and CV Space Pressure Control StatitracMorning Warm-up Options Emergency OverrideControls VAV and CV Ventilation Override Module VOMHuman Interface Panel Main Menu Human Interface Panel HIGeneric Building Automation System Module Gbas 0-5 vdc Generic Building Automation System Module Gbas 0-10 vdc Chilled Water Coil Freeze StatSteam and Hot Water Coil Freeze Avoidance Night Setback SensorsDry Bulb Temperature Control of Economizer Occupied/Unoccupied input on the RTMTrane Tracer or BAS System Timed Override ActivationHumidification Control LonTalk Building Automation SystemReturn Fan Control TwinningApplications Considerations Exhaust/Return Fan OptionsApplication Recommendations AdvantagesSupply and Return Airflow Configurations Applications ConsiderationsSupply Airflow Configuration Return Airflow ConfigurationWith Bag CartridgeCorrosive Atmospheres Ventilation Override SequencesNatural Gas Heating Considerations Acoustical ConsiderationsUnit Placement Clearance RequirementsExternal Piping Enclosure Duct DesignProtecting Hydronic Coils From Freezing Selection Procedure Selection Procedure Exhaust Fan Motor Sizing Return Fan Motor SizingUnit Electrical Requirements Altitude CorrectionsModel Number Description Digit 7 Chilled Water Coil FIN SeriesModel Number Description Digit 20 System Control SelectionDigit 38 Belt Guards Burglar BARS/MARINE Lights General Data All dimensions in inches General DataGeneral Data Gas Heat Inputs/Input Ranges Economizer Outdoor Air Damper Leakage at rated airflowiInputs MBH Input MBH Range MBH Standard Damper Optional Low Leak DamperPerformance Adjustment Factors Wet Bulb Temperature Btu per PoundEnthalpy of Saturated Air Gas Heating Capacity Altitude Correction FactorsDB F WB F Performance Data-Chilled Water Coil CapacitiesChilled Water Coil Capacities-2 Row 5W Performance Data-Chilled Water Coil Capacities Chilled Water Coil Capacities-4 Row WChilled Water Coil Capacities-6 Row WD Chilled Water Coil Capacities-8 Row WD Supply Fan Performance Standard CFM Casing a Total Static Pressure Std Air1644 Supply Fan w/o IGV Supply Fan Performance Standard CFM -Casing B 9311117 Supply Fan Performance Standard CFM-Casing B Supply Fan Performance Standard CFM Casing C 7491019 Total Static Pressure Std AirPerformance Data Supply Fan with Inlet Guide Vanes Performance Data Supply Fan with Inlet Guide Vanes Supply Fan Performance Standard CFM-Casing a Supply Fan Performance Standard CFM Casing B 1093 1600 RPM 1500 RPM 779 1021 1283 Performance Data-Exhaust Fan Negative Static Pressure Std AirPerformance Data-Exhaust Fan Static PresureInWC237i Wocfm Exhaust Fan Performance Standard CFM-Case C 32 Fan 4150 R P M Performance Data-Return Fan Return Fan Performance Standard CFM-Case a 36.5 FanPerformance Data-Return Fan Return Fan PerformanceReturn Fan Performance Standard CFM-Case B and Case C 40 Fan Return Fan Performance Electric Heat Air Temperature Rise Performance Data-HeatNatural Gas Heating Capacities1 Electric Heat kw RangesPerformance Data-Heat Hot Water Coil Heating Capacities Q/ITDSteam Coil Heating Capacities Q/ITD Properties of SteamChilled Water Coil Airside Pressure Drop in H20 Component Static Pressure Drops in. H2OFilters Prefilter High Low PD Cartridge Bag FiltersCartridge Filters Throw Temp Hi Temp Away Prefilter Casing Supply Air Fan Drive Selections Drive NoHorse Power HP Low Casing Std Exhaust Air Fan Drive SelectionsReturn Air Fan Drive Selections 15 HP 20 HP 25 HP 30 HP 40 HP Drive NoElectrical Service Sizing Electrical DataSet 1. Cooling with Gas Heat Air Handling Units Set 2. Cooling with Electric HeatElectrical Service Sizing Data-Motors Electrical Data Voltage Utilization RangeUnit Voltage Nominal Tons Voltage 460 575 FLA Add 90-150Dimensional Data Unit Top/Front ViewReturn Exhaust Unit Height Fan Casing Dimensional DataUnit Dimensions In.-One-Piece Unit Supply Opening Blank Casing Gas Heat Section Downflow/Horizontal Airflow Configuration DimensionsOpening Electrical Entry Details Piping Chilled Water Piping Locations Minimum Required Clearance Unit Option Selection Door Swing Ft. StandardMinimum Required Clearance Ft Control Exh BoxCross Member Location Blank Casing Section Dimensions Blank Casing SectionBlank Casing Section Field Installed Sensors Variable Air Volume VAV Field Installed Sensors Constant Volume CV Field Installed Sensors VAV and CV Wireless Zone Sensor Wall or Duct Mount CO2 Zone Sensors Component Weights Lbs WeightsApproximate Operating Weights Lbs Weights Size Wt lbs Control Box Main 454 Convenience Outlet Roof Curb WeightsInstalled Shipping Casing Blank Weight Options Options FiltersFresh Air System ControlAgency Approval Miscellaneous OptionsField Installed Accessories Electronic Zone SensorsRoof Curb Electrical System Mechanical SpecificationsGeneral Mechanical Specifications Cooling System Chilled Water Coil Water ValveExternal Piping Enclosure Air Handling SystemMechanical Specifications Filters Mechanical Specifications Exhaust AirNo Relief Standard Percent Modulating Exhaust Fan OptionMechanical Specifications Return Air Fresh AirHeating System CO2 Sensing Page RT-PRC031-EN