Trane RT-PRC031-EN manual Options

Page 94

Options

A full range of factory installed options are available, allowing for the air handler design that best suits each individual application.

Chilled Water Cooling

ARI certified type 5W, W, or WD coils provided with water modulating valve and actuator. Turbulators and various row, fin series, and valve options are available.

Cooling Only/Heating Casings

Cooling Only—Extended casing of solid double wall construction with foam injected insulation throughout the air handler.

Electric Heat—Nickel-chromium electric heating elements in individually fused circuits of 48 amps or less and with all necessary safeties. A full range of sizing options is available.

Natural Gas Heat-Two-Stage— Two-pass stainless steel tubular free floating heat exchanger has industrial type burner and combustion blower. Available with high, medium and low fire and UL and CSA approval.

Natural Gas Heat-Full Modulation—The heat exchanger drum, tubes and front and rear headers are constructed of corrosion resistant stainless steel. Available with high, medium and low fire and UL and CSA approval.

Steam Heat—ARI certified type NS coil with non-freeze steam distribution. Coils are pitched for drainage and are provided with steam modulating valve with actuator. High and low heat options are available.

Hot Water Heat—ARI certified type 5W coil mounted for drainage and provided with hot water modulating valve with actuator. High and low heat options are available.

Blank Sections

Four Foot Blank Section—Solid double wall construction with foam injected insulation. The blank section is located at the airflow discharge. Single point latching, hinged access doors are located on either side of the blank section. Final filter options are available for cooling only units.

Eight Foot Blank Section—Solid double wall construction with foam injected insulation. The blank section is located at the airflow discharge. Single point latching, hinged access doors are located on either side of the blank section. Final filter options are available for all units.

Fan Options

Standard CFM supply exhaust/ return fans—Available to meet standard airflow application needs.

Low CFM exhaust fans— Available to meet low leaving air temperature requirements.

Power Supply

Air Handlers are available with 460 or 575 voltage, 3 phase 60 hertz power supply.

Exhaust

No Exhaust—Air Handlers can be built for makeup air applications with no exhaust. Relief opening is sealed watertight.

100 Percent Modulating Exhaust Fan—A double width, double inlet forward-curved fan can exhaust up to 100 percent supply air. The fan operates when economizer damper is open greater than minimum position. Discharge dampers at fan outlet modulate in response to economizer damper position on Constant Volume (CV) air handlers.

100 Percent Modulating Exhaust Fan with Statitrac™ Control—

For both CV and Variable Air Volume (VAV) air handlers, the 100 percent modulating exhaust discharge dampers are modulated in response to building pressure. A differential pressure control system, Statitrac, uses a differential pressure transducer to compare indoor building pressure to atmospheric pressure. The FC exhaust fan is turned on when required to lower building static pressure to setpoint. The Statitrac control system then modulates the discharge dampers to control the building pressure to within the adjustable, specified deadband that is set at the Human Interface Panel.

100 Percent Modulating Exhaust Fan with Statitrac Control and Variable Frequency Drive— Provided with all the necessary controls to control/maintain building space pressure through a CV or VAV air handler. The Variable Frequency Drive (VFD) modulates the speed of the exhaust fan motor in response to building pressure. A differential pressure control system, Statitrac, uses a differential pressure transducer to compare indoor building pressure to atmospheric pressure. The 0-100% modulating relief dampers modulate in response to a signal from the unit microprocessor, based upon the space static pressure, and causes the damper to modulate open or closed as required to maintain the space pressure within the deadband.

100 Percent Modulating Exhaust Fan with Statitrac Control and Variable Frequency Drive and Bypass—Bypass control provides full nominal airflow in the event of drive failure.

Return

100 Percent Modulating Return Fan—A single width plenum fan with airfoil blade can relieve up

94

RT-PRC031-EN

Image 94
Contents IntelliPak II Air Handlers Introduction Table of Contents Standard Features Features and BenefitsControls Cabinet Mechanical Features and Benefits Optional Features Installation and Service Features and Benefits Field Installed AccessoriesFeatures Summary ReliabilityIntegrated Comfort with Trane Tracer LCI Features and Benefits Application FlexibilitySimplifying the Comfort System Interoperability Features and BenefitsOptimum Building Comfort Control Statitrac Direct Space Building Pressurization Control StatitracSupply Fans with Inlet Guide Vanes Variable Frequency Drives VFDControls Variable Air Volume VAV Only Supply Air Temperature Controls Supply Air Pressure ControlSupply Air Setpoint Reset Controls Variable Air Volume VAV OnlyHeating Zone Temperature Control Heating Controls Constant Volume CV OnlyOccupied Zone Temperature Control Gas Heating Two-StageCooling and Heating Controls Constant Volume CV Only Auto ChangeoverUnoccupied Zone Temperature Control Hot Water or Steam HeatingMorning Warm-up Options Controls VAV and CVSpace Pressure Control Statitrac Emergency OverrideControls VAV and CV Ventilation Override Module VOMGeneric Building Automation System Module Gbas 0-5 vdc Human Interface Panel HIHuman Interface Panel Main Menu Steam and Hot Water Coil Freeze Avoidance Generic Building Automation System Module Gbas 0-10 vdcChilled Water Coil Freeze Stat Night Setback SensorsTrane Tracer or BAS System Dry Bulb Temperature Control of EconomizerOccupied/Unoccupied input on the RTM Timed Override ActivationReturn Fan Control Humidification ControlLonTalk Building Automation System TwinningApplication Recommendations Applications ConsiderationsExhaust/Return Fan Options AdvantagesSupply and Return Airflow Configurations Applications ConsiderationsWith Bag Supply Airflow ConfigurationReturn Airflow Configuration CartridgeNatural Gas Heating Considerations Corrosive AtmospheresVentilation Override Sequences Acoustical ConsiderationsUnit Placement Clearance RequirementsProtecting Hydronic Coils From Freezing Duct DesignExternal Piping Enclosure Selection Procedure Selection Procedure Unit Electrical Requirements Exhaust Fan Motor SizingReturn Fan Motor Sizing Altitude CorrectionsModel Number Description Digit 7 Chilled Water Coil FIN SeriesModel Number Description Digit 20 System Control SelectionDigit 38 Belt Guards Burglar BARS/MARINE Lights General Data All dimensions in inches General DataGeneral Data Inputs MBH Input MBH Range MBH Gas Heat Inputs/Input RangesEconomizer Outdoor Air Damper Leakage at rated airflowi Standard Damper Optional Low Leak DamperEnthalpy of Saturated Air Performance Adjustment FactorsWet Bulb Temperature Btu per Pound Gas Heating Capacity Altitude Correction FactorsChilled Water Coil Capacities-2 Row 5W Performance Data-Chilled Water Coil CapacitiesDB F WB F Performance Data-Chilled Water Coil Capacities Chilled Water Coil Capacities-4 Row WChilled Water Coil Capacities-6 Row WD Chilled Water Coil Capacities-8 Row WD Supply Fan Performance Standard CFM Casing a Total Static Pressure Std Air1644 Supply Fan w/o IGV Supply Fan Performance Standard CFM -Casing B 9311117 Supply Fan Performance Standard CFM-Casing B Supply Fan Performance Standard CFM Casing C 7491019 Total Static Pressure Std AirPerformance Data Supply Fan with Inlet Guide Vanes Performance Data Supply Fan with Inlet Guide Vanes Supply Fan Performance Standard CFM-Casing a Supply Fan Performance Standard CFM Casing B 1093 1600 RPM 1500 RPM 779 1021 1283 Performance Data-Exhaust Fan Negative Static Pressure Std AirPerformance Data-Exhaust Fan Static PresureInWC237i Wocfm Exhaust Fan Performance Standard CFM-Case C 32 Fan 4150 R P M Performance Data-Return Fan Return Fan Performance Standard CFM-Case a 36.5 FanPerformance Data-Return Fan Return Fan PerformanceReturn Fan Performance Standard CFM-Case B and Case C 40 Fan Return Fan Performance Natural Gas Heating Capacities1 Electric Heat Air Temperature RisePerformance Data-Heat Electric Heat kw RangesSteam Coil Heating Capacities Q/ITD Performance Data-HeatHot Water Coil Heating Capacities Q/ITD Properties of SteamChilled Water Coil Airside Pressure Drop in H20 Component Static Pressure Drops in. H2OCartridge Filters Throw Temp Hi Temp Away Prefilter Casing High Low PD Cartridge Bag FiltersFilters Prefilter Supply Air Fan Drive Selections Drive NoReturn Air Fan Drive Selections Horse Power HP Low Casing StdExhaust Air Fan Drive Selections 15 HP 20 HP 25 HP 30 HP 40 HP Drive NoSet 1. Cooling with Gas Heat Air Handling Units Electrical Service SizingElectrical Data Set 2. Cooling with Electric HeatElectrical Service Sizing Data-Motors Unit Voltage Electrical DataVoltage Utilization Range Nominal Tons Voltage 460 575 FLA Add 90-150Dimensional Data Unit Top/Front ViewUnit Dimensions In.-One-Piece Unit Dimensional DataReturn Exhaust Unit Height Fan Casing Opening Downflow/Horizontal Airflow Configuration DimensionsSupply Opening Blank Casing Gas Heat Section Electrical Entry Details Piping Chilled Water Piping Locations Minimum Required Clearance Ft Control Minimum Required ClearanceUnit Option Selection Door Swing Ft. Standard Exh BoxBlank Casing Section Dimensions Blank Casing SectionCross Member Location Blank Casing Section Field Installed Sensors Variable Air Volume VAV Field Installed Sensors Constant Volume CV Field Installed Sensors VAV and CV Wireless Zone Sensor Wall or Duct Mount CO2 Zone Sensors Approximate Operating Weights Lbs WeightsComponent Weights Lbs Weights Installed Shipping Casing Blank Weight Roof Curb WeightsSize Wt lbs Control Box Main 454 Convenience Outlet Options Options FiltersFresh Air System ControlAgency Approval Miscellaneous OptionsField Installed Accessories Electronic Zone SensorsRoof Curb General Mechanical SpecificationsElectrical System External Piping Enclosure Mechanical Specifications Cooling System Chilled Water CoilWater Valve Air Handling SystemMechanical Specifications Filters No Relief Standard Mechanical SpecificationsExhaust Air Percent Modulating Exhaust Fan OptionMechanical Specifications Return Air Fresh AirHeating System CO2 Sensing Page RT-PRC031-EN