Trane RT-PRC031-EN manual High Low PD Cartridge Bag Filters, Filters Prefilter

Page 73

Performance Data—Component Static Pressure Drops/

Fan Drive Selections

Table 35 Component Static Pressure Drops (in. H2O)

 

 

Standard Filter Section (Cooling Coil)

 

Final Filter Section (Cooling Coil)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90-95%

90-95%

 

90-95%

 

90-95%

 

 

 

 

 

 

90-95%

90-95%

Std

 

 

Std 2"

90-95%

90-95%

90-95%

Std Temp

Std

Hi Temp

Temp

 

 

Low PD

Temp

Std Temp

Cartridge

Hi Temp

HEPA

 

 

High

Low PD

Cartridge

Bag

Cartridge

Bag

Cartridge

Filters

HEPA

Filters

 

 

Eff

Cartridge

Filters

Filters

Filters

Filters

Filters

w/ 2" Hi

w/ 2"

w/ 2"

 

 

Throw

Filters

w/ 2"

w/ 2"

w/4”

w/ 2"

w/ 2"

Temp

Hi Temp

Hi Temp

 

 

Away

w/ 2"

Prefilter

Prefilter

Prefilter

Prefilter

Prefilter

Prefilter

Prefilter

Prefilter

Casing

CFM

Filters

Prefilter

(i)

(ii)

(iii)

(iv)

(v)

(vi)

(vii)

(viii)

 

 

 

 

 

 

 

 

 

 

 

 

 

16000

0.08

0.24

0.27

0.34

0.23

0.36

0.29

0.35

0.54

0.48

 

 

 

 

 

 

 

 

 

 

 

 

 

20000

0.11

0.29

0.32

0.39

0.29

0.42

0.34

0.42

0.66

0.58

 

 

 

 

 

 

 

 

 

 

 

 

 

23000

0.11

0.29

0.32

0.39

0.29

0.42

0.34

0.42

0.66

0.58

 

 

 

 

 

 

 

 

 

 

 

 

A, B, C

28000

0.18

0.49

0.49

0.56

0.51

0.61

0.54

0.68

1.01

0.88

33000

0.23

0.61

0.61

0.67

0.65

0.73

0.69

0.86

1.22

1.06

 

 

 

 

 

 

 

 

 

 

 

 

 

 

38000

0.28

0.74

0.76

0.78

0.81

0.86

0.86

1.06

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

43000

0.33

0.89

0.92

0.91

0.98

1.00

1.05

1.30

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

45000

0.36

0.95

0.99

0.96

1.05

1.06

1.13

1.40

-

-

 

 

 

 

 

 

 

 

 

 

 

 

(i)Case A, B, C Max CFM 50000

(ii)Case A, B, C Max CFM 50000

(iii)Case A, B, C Max CFM 55500

(iv)Case A, B, C Max CFM 46250

(v)Case A, B, C Max CFM 46250

(vi)Case A, B, C Max CFM 46250

(vii)Case A, B, C Max CFM 37000

(viii)Case A, B, C Max CFM 37000

RT-PRC031-EN

73

Image 73
Contents IntelliPak II Air Handlers Introduction Table of Contents Standard Features Features and BenefitsControls Cabinet Mechanical Features and Benefits Optional Features Features Summary Features and Benefits Field Installed AccessoriesInstallation and Service ReliabilityIntegrated Comfort with Trane Tracer LCI Features and Benefits Application FlexibilitySimplifying the Comfort System Interoperability Features and BenefitsOptimum Building Comfort Control Statitrac Statitrac Direct Space Building Pressurization ControlVariable Frequency Drives VFD Supply Fans with Inlet Guide VanesSupply Air Temperature Controls Supply Air Pressure Control Controls Variable Air Volume VAV OnlySupply Air Setpoint Reset Controls Variable Air Volume VAV OnlyHeating Zone Temperature Control Occupied Zone Temperature Control Controls Constant Volume CV OnlyHeating Gas Heating Two-StageUnoccupied Zone Temperature Control Controls Constant Volume CV Only Auto ChangeoverCooling and Heating Hot Water or Steam HeatingSpace Pressure Control Statitrac Controls VAV and CVMorning Warm-up Options Emergency OverrideVentilation Override Module VOM Controls VAV and CVGeneric Building Automation System Module Gbas 0-5 vdc Human Interface Panel HIHuman Interface Panel Main Menu Chilled Water Coil Freeze Stat Generic Building Automation System Module Gbas 0-10 vdcSteam and Hot Water Coil Freeze Avoidance Night Setback SensorsOccupied/Unoccupied input on the RTM Dry Bulb Temperature Control of EconomizerTrane Tracer or BAS System Timed Override ActivationLonTalk Building Automation System Humidification ControlReturn Fan Control TwinningExhaust/Return Fan Options Applications ConsiderationsApplication Recommendations AdvantagesApplications Considerations Supply and Return Airflow ConfigurationsReturn Airflow Configuration Supply Airflow ConfigurationWith Bag CartridgeVentilation Override Sequences Corrosive AtmospheresNatural Gas Heating Considerations Acoustical ConsiderationsClearance Requirements Unit PlacementProtecting Hydronic Coils From Freezing Duct DesignExternal Piping Enclosure Selection Procedure Selection Procedure Return Fan Motor Sizing Exhaust Fan Motor SizingUnit Electrical Requirements Altitude CorrectionsDigit 7 Chilled Water Coil FIN Series Model Number DescriptionDigit 20 System Control Selection Model Number DescriptionDigit 38 Belt Guards Burglar BARS/MARINE Lights General Data General Data All dimensions in inchesGeneral Data Economizer Outdoor Air Damper Leakage at rated airflowi Gas Heat Inputs/Input RangesInputs MBH Input MBH Range MBH Standard Damper Optional Low Leak DamperWet Bulb Temperature Btu per Pound Performance Adjustment FactorsEnthalpy of Saturated Air Gas Heating Capacity Altitude Correction FactorsChilled Water Coil Capacities-2 Row 5W Performance Data-Chilled Water Coil CapacitiesDB F WB F Chilled Water Coil Capacities-4 Row W Performance Data-Chilled Water Coil CapacitiesChilled Water Coil Capacities-6 Row WD Chilled Water Coil Capacities-8 Row WD Total Static Pressure Std Air Supply Fan Performance Standard CFM Casing a1644 Supply Fan w/o IGV 931 Supply Fan Performance Standard CFM -Casing B1117 Supply Fan Performance Standard CFM-Casing B 749 Supply Fan Performance Standard CFM Casing C1019 Std Air Total Static PressurePerformance Data Supply Fan with Inlet Guide Vanes Performance Data Supply Fan with Inlet Guide Vanes Supply Fan Performance Standard CFM-Casing a Supply Fan Performance Standard CFM Casing B 1093 1600 RPM 1500 RPM 779 1021 1283 Negative Static Pressure Std Air Performance Data-Exhaust FanStatic PresureInWC Performance Data-Exhaust Fan237i Wocfm 415 Exhaust Fan Performance Standard CFM-Case C 32 Fan0 R P M Return Fan Performance Standard CFM-Case a 36.5 Fan Performance Data-Return FanReturn Fan Performance Performance Data-Return FanReturn Fan Performance Standard CFM-Case B and Case C 40 Fan Return Fan Performance Performance Data-Heat Electric Heat Air Temperature RiseNatural Gas Heating Capacities1 Electric Heat kw RangesHot Water Coil Heating Capacities Q/ITD Performance Data-HeatSteam Coil Heating Capacities Q/ITD Properties of SteamComponent Static Pressure Drops in. H2O Chilled Water Coil Airside Pressure Drop in H20Cartridge Filters Throw Temp Hi Temp Away Prefilter Casing High Low PD Cartridge Bag FiltersFilters Prefilter Drive No Supply Air Fan Drive SelectionsExhaust Air Fan Drive Selections Horse Power HP Low Casing StdReturn Air Fan Drive Selections 15 HP 20 HP 25 HP 30 HP 40 HP Drive NoElectrical Data Electrical Service SizingSet 1. Cooling with Gas Heat Air Handling Units Set 2. Cooling with Electric HeatElectrical Service Sizing Data-Motors Voltage Utilization Range Electrical DataUnit Voltage Nominal Tons Voltage 460 575 FLA Add 90-150Unit Top/Front View Dimensional DataUnit Dimensions In.-One-Piece Unit Dimensional DataReturn Exhaust Unit Height Fan Casing Opening Downflow/Horizontal Airflow Configuration DimensionsSupply Opening Blank Casing Gas Heat Section Electrical Entry Details Piping Chilled Water Piping Locations Unit Option Selection Door Swing Ft. Standard Minimum Required ClearanceMinimum Required Clearance Ft Control Exh BoxBlank Casing Section Dimensions Blank Casing SectionCross Member Location Blank Casing Section Field Installed Sensors Variable Air Volume VAV Field Installed Sensors Constant Volume CV Field Installed Sensors VAV and CV Wireless Zone Sensor Wall or Duct Mount CO2 Zone Sensors Approximate Operating Weights Lbs WeightsComponent Weights Lbs Weights Installed Shipping Casing Blank Weight Roof Curb WeightsSize Wt lbs Control Box Main 454 Convenience Outlet Options Filters OptionsSystem Control Fresh AirMiscellaneous Options Agency ApprovalElectronic Zone Sensors Field Installed AccessoriesRoof Curb General Mechanical SpecificationsElectrical System Water Valve Mechanical Specifications Cooling System Chilled Water CoilExternal Piping Enclosure Air Handling SystemMechanical Specifications Filters Exhaust Air Mechanical SpecificationsNo Relief Standard Percent Modulating Exhaust Fan OptionFresh Air Mechanical Specifications Return AirHeating System CO2 Sensing Page RT-PRC031-EN