Lennox International Inc Typical ML193DF Field Wiring Diagram, Thermostat Designations

Page 34

ML193DF and CONDENSING UNIT

THERMOSTAT DESIGNATIONS

(Refer to specific thermostat and outdoor unit.)

Thermostat

Furnace

Condensing

 

 

Unit

Install the room thermostat according to the instruc- tions provided with the thermostat. See figure 50 for thermostat designations. If the furnace is being matched with a heat pump, refer to the FM21 installa- tion instruction or appropriate dual fuel thermostat in- structions.

Indoor Blower Speeds

R

W1

Y

G

C

POWER

HEAT

COOLING

INDOOR BLOWER

COMMON

R

W

Y

G

C

*CONDENSING

UNIT

CONDENSING

UNIT

CONDENSING UNIT COMMON

1 − When the thermostat is set to AN ON," the indoor blower will run continuously on the heating speed when there is no cooling or heating demand.

2 − When the ML193DF is running in the heating mode, the indoor blower will run on the heating speed.

3 − When there is a cooling demand, the indoor blower will run on the cooling speed.

*NOTE −

FIGURE 50

TYPICAL ML193DF FIELD WIRING DIAGRAM

IGNITOR

*NOTE −

*R

FIGURE 51

Page 34

Image 34
Contents Installation Instructions ML193DF Table of ContentsML193DF Unit Dimensions − inches mm ML193DFControl BOX BAG AssemblyML193DF Parts Arrangement Blower MotorML193DF Gas Furnace Safety InformationDirect Vent Installation NON−DIRECT Vent Shipping and Packing ListUse of Furnace as Construction Heater General Combustion, Dilution & Ventilation AirEquipment in Confined Space − ALL AIR from Inside Shipping Bolt Removal Equipment in Confined Space − ALL AIR from OutsideSetting Equipment Installation − Setting EquipmentFront Horizontal Back NON−COMBUSTIBLE Floor Opening Size NC‡Side View Combustible Flooring Base Opening Size− Seal the cabinet and check for air leaks Filters Pipe & Fittings SpecificationsPiping and Fittings Specifications Duct SystemOutdoor Termination Kits Usage Piping Suspension Guidelines Joint Cementing ProcedureVenting Practices ScheduleMinimum Vent Pipe Lengths Vent Piping GuidelinesML193DF MIN. Vent Length Model Maximum Allowable Intake or Exhaust Vent Length in Feet Typical Intake Pipe Connections Typical Exhaust Pipe ConnectionsIntake Exhaust Typical AIR Intake Pipe Connections Inside Corner Detail Inches 305mm or 12 in mmUS Installations1 Canadian Installations2 Direct Vent Roof Termination KIT − On field supplied terminations, a minimum distanceFLUSH−MOUNT Side Wall Termination KIT 51W11 51mm 76mm Vent Pipe Unconditioned Space Reducer MAY beRequired to Adapt SupportFront View Top ViewExhaust 203mm − 305mm NON−DIRECT Vent Roof Termination KITML193DF NON−DIRECT Vent Application Using Existing Chimney ML193DF with Evaporator Coil To drainTrap / Drain Assembly Using 1/2 PVC or 3/4 PVC Gas Piping Furnace Isolate GAS ValveGAS Pipe Capacity − FT3/HR kL/HR Electrical Precautions and ProceduresElectrostatic Discharge ESD Exterior MAKE−UP BOX FACTORY− Installed Left Side MAKE−UPInterior MAKE−UP BOX BOX InsideTypical ML193DF Field Wiring Diagram Thermostat DesignationsTypical ML193DF Wiring Diagram Integrated Control For Your Safety Read Before OperatingUnit Start−Up Automatic Hot Surface Ignition SystemPage Proper Combustion Gas Pressure AdjustmentGAS Meter Clocking Chart High Altitude Information2286m 3048m 2286 − 3038m73W37 73W81 68W68 74W90 74W91 69W73 Heat FAN-OFF Time in Seconds Other Unit AdjustmentsNo Jumper Blower Data High Low In. w.g Cfm Watts Cfm Watts cfm WattsService Electrical SHOCK, Fire Or Explosion HazardPage Diagnostic Codes Planned ServiceIgnition Control Board Diagnostic Codes LED #1 Red LED #2 GreenNormal Heating Mode Abnormal Heating Mode Troubleshooting Heating Sequence of OperationHeating Sequence of Operation Heating Sequence Normal Cooling Mode Abnormal Cooling Mode Troubleshooting Cooling Sequence of OperationCooling Sequence of Operation Troubleshooting Continuous Fan Sequence of Operation Continuous Heat Speed FAN Sequence of OperationRepair Parts List Return AIR Duct System Supply AIR Duct Start−Up & Performance Check ListGAS Supply Intake / Exhaust PipeCondensate Line Thermostat Temperature RiseTotal External Static Drain Line Vent PipeRequirements for Commonwealth of Massachusetts LY BELOW. Keep Clear of ALL OBSTRUC- Tions