Fan and Heater
HEATER INSTALLATION
Bin Configuration
IMPORTANT! When mounting (2) heaters on a bin it is imperative that they be situated as illustrated in this drawing. Plenum thermostat must be to the right of master heater and master heater must be to the right of slave heater.
THIS TABLE IS NOT INTENDED AS A DRYING GUIDE.
IT SHOULD BE USED AS A REFERENCE FOR SETTING MAXIMUM PLENUM
TEMPERATURE FOR SAFE OPERATION.
Operating Temperature Table
| HIGH- | HIGH- | CONTINUOUS | |
TEMP | TEMP | |||
FLOW | ||||
BATCH | BATCH DRY | WITH | ||
(RECIRCULATING) | ||||
| NO STIRRING | STIRRING | ||
|
| |||
|
|
|
|
| 1200 | 1400 | 1600 | IMPORTANT! | |
CORN | ABOVE | DO NOT EXCEED | |||
AMBIENT |
|
|
| ||
|
|
|
|
| |
| TEMP |
|
|
| PLENUM |
|
|
|
|
| |
|
|
|
| TEMPERATURES | |
RICE | ABOVE | 1000 | 1000 | NOT | LISTED IN TABLE |
| AMBIENT |
|
| RECOMMENDED |
|
| TEMP |
|
|
|
|
|
|
|
|
|
|
BEANS |
|
|
|
| |
ABOVE | 1100 | 1200 | NOT |
| |
& |
| ||||
AMBIENT |
|
| RECOMMENDED |
| |
WHEAT |
|
|
| ||
TEMP |
|
|
|
| |
|
|
|
|
| |
|
|
|
|
|
|
25