Page 28

VANE AXIAL GAS HEATER SPECIFICATIONS

Fan and Heater

BTU's per Gauge Pressure (PSI) Propane Models (Approximate)

High Temperature

 

 

 

 

Operating Pressure (PSI)

 

 

 

Diameter

2

4

6

8

10

12

14

16

18

20

 

 

 

 

 

 

 

 

 

 

 

18"

416380

588680

720290

832760

930880

1019420

1107800

1174960

1244360

1340080

24"

598250

844730

1036170

1198890

1340080

1464520

1581770

1689460

1787570

1892860

26"

816010

1148640

1409480

1632030

1825860

1995762

2153700

2302070

2436070

2577260

28"

935660

1318540

1617670

1868930

2091480

2309250

2467180

2649050

2792630

2955360

 

 

 

 

 

 

 

 

 

 

 

Low Temperature

 

 

 

 

Operating Pressure (PSI)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Diameter

2

4

6

8

10

12

14

16

18

20

 

 

 

 

 

 

 

 

 

 

 

18"

102900

145970

181870

208190

234510

253660

275200

294340

311090

335020

24-28"

148370

210580

258440

299130

335020

366130

394850

421170

447490

473810

 

 

 

 

 

 

 

 

 

 

 

Gauge Pressure (Psi) Required To Maintain Temperature (Approximate)

(HIGH TEMP UNITS ONLY)

 

Static

 

 

Heat Rise Degrees F

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan Model

6 0

80

100

120

140

160

180

 

Pressure

 

 

1"

2

3

4

5

6

8

9

 

3HP-18"

2"

1

1

2

3

4

5

6

 

 

3"

low-temp

low-temp

1

2

2

3

3

 

 

 

 

 

 

 

 

 

 

 

 

1"

2

4

6

8

1 0

1 4

1 7

 

 

2"

1

3

4

5

7

9

1 1

 

7HP-24"

3"

low-temp

low-temp

1

2

3

3

4

 

 

4"

low-temp

low-temp

low-temp

low-temp

1

2

3

 

 

 

 

 

 

 

 

 

 

 

 

1"

4

6

9

1 3

1 8

2 2

2 6

 

 

2"

3

5

8

1 0

1 4

1 8

2 2

 

10HP-24"

3"

2

3

4

6

8

9

1 1

 

 

4"

1

2

3

4

5

6

8

 

 

 

 

 

 

 

 

 

 

 

 

1"

2

4

6

8

1 1

1 4

1 8

 

 

2"

2

4

5

7

9

1 3

1 6

 

15HP-26"

3"

1

3

4

5

7

1 0

1 3

 

 

4"

1

3

4

5

7

9

1 1

 

 

5"

low-temp

1

2

3

3

4

5

 

 

 

 

 

 

 

 

 

 

 

 

1"

3

4

7

9

1 2

1 6

2 0

 

 

2"

2

4

6

8

1 1

1 4

1 8

 

15HP-28"

3"

2

3

4

5

8

1 0

1 3

 

 

4"

1

2

3

4

6

8

1 0

 

 

5"

low-temp

1

2

3

3

4

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28

Image 28
Contents Service Manual Page Table of Contents Roof WARNING, Operation & Safety Safety Alert SymbolRoof Damage Warning and Disclaimer Proper Use of ProductPower Warning SafetyFuel Warning Page Vane Axial Fans FAN Installation Previously Installed UnitsProper Installation of the Ground Rod Machine to Earth GroundTest Station FAN Specifications RPM Vane Axial FanFAN FAN Troubleshooting Fan Troubleshooting ChartFan Control Circuit TroubleshootingPush Start Button, Nothing Happens FAN Wiring and Schematic Volt 1 Phase 15 HPFAN Service LubricantMotors with Regreasing Grease in motor bearingsHub Bolt Torque Requirement for Fan Blades 84 ft. lbs. Trantorque14 1HP 18-1.5HPCentrifugal FAN Service Guide RPM FAN RPM FAN Specifications 150 200 100 Volt 1 Phase 15 HP Marathon FAN Schematic and WiringSchematic Wiring Diagram Lubrication ProcedureRelubrication Intervals 15HP 3500RPM fans 16ft. lbs. Browning 29ft. lbs. BrowningGas Heater Service Guide Bin Configuration Heater InstallationOperating Temperature Table Disconnectand LOCK-OUT Power Before Servicing Heater Replacing HF-7100 Board with HF-7318High Temperature Heater Specifications Low Temperature Heater SpecificationsVane Axial GAS Heater Specifications BTUs per Gauge Pressure PSI Propane Models ApproximateBTUs Gauge Pressure PSI Natural Gas Models Approximate CHI-TOWN GAS Heater Specifications Low & Medium Temperature ModelsCHI-TOWN Heater Specifications High TemperatureMED Temperature Btus Per Gauge Pressure Psi Natural Gas Models ApproximateDownwind Heater Specifications Centrifugal Heater SpecificationsAir Pressure Switch Temperature Sensor Box Installation Transition Hi-limit InstallationHeater Unit Wiring Secondary Heater UnitInstalling Optional Humidity Sensor Figure aOperating Procedure Power UpNormal Operating Displays With Heater Not Running Setting Gas Pressure Starting The DryerOperating Procedure AIR Pressure Switch Adjusting the Air Pressure SwitchAdjusting The Vaporizor Running The DryerProgramming Set Points Drying Grain Hours To Shutdown Mode Programming Hours To ShutdownRun Hours Display Multiple Heater NotesModulating Valve Operation Amount of gas used by the heaterConfiguration Dip Switches Normally Done Factory ConfigurationAt GSI Error Conditions Limit SwitchesMultiple Heater Error Conditions Misc Error NumbersHeater Service Wiring Diagram Turn Control Power on dryer to the off position Programing Instructions for Series 2000 Heater+18% Programmer Hook UpHeater Electrical Installation 230V Fans Heater Electrical InstallationConnect power cord to fan control box Transition HI-LIMIT Installation Mount the housing to the bin Sidewall to sealPlenum Thermostat Mounting To the right sideAnnual Heater Inspection For Units Using HF-7318 Control Board Installation For Standard UnitsRun 2 wires 18 gage between master and slave unit FAN PartsWiring Schematic Standard Heater Wiring Standard Heater Schematic TROUBLE-SHOOTING Flow Chart HousingTrouble Shooting Chart 7528% 352%$%/&$86Fan and Heater Gas Heaters Deluxe Heater Wiring Deluxe Heater Schematic Heaters Installation Standard Units 2ND Heater InstallationInstallation HI-LO Units Standard Heaters not HI-LO fire Smart BoardHI-LO Fire Heater Light Identification Troubleshooting ChartDescription Fan And Heater Downwind Heat Adjustment Procedure For Heaters Manufactured afterGAS Heaters 2ND Heater Installation Wiring Schematic GAS Heaters Electrical CHECK-OUT Chart Purge DelayTime Delay Reset Flame Probe2ND Heater Installation PRE-1990 GAS Heaters Heater Wiring Diagram Heater Schematic Vane Axial LP HeaterVane Axial Vapor Heater Downwind LP Heater Downwind Vapor Heater Lo-Fire Downwind Heater Miscellaneous Information 1991-1993PNEG-286 Flame Detector Kit Installation Flame Detector KIT InstallationPart Number HF-7136 1994-1995PNEG-286 Flame Detector Kit Installation PRESENTPNEG-286 Installation SELF-OPERATED Modulating ValvesApplication OperationBypass Orifice Selection Orifice Sizes in Kit Number PLG14A-600RAdjustment Checkout ProcedureRepairs and Replacement Replacement PartsInstallation Instructions Manual ResetFENWAL-SERIES SeriesSpecifications Flame SensingElectrode Application Control Board CommentsFan and Heater Control Board System ChecksPolarity Check Initial OperationFENWAL-SERIES Safety Checks Repair and ReplacementsLimited Warranty Statement WARRANTY/SERVICE NotesTwisto Says Motor Capacitor Chart Page 1004 E. Illinois St Assumption, IL Phone Fax February