SELF-OPERATED MODULATING VALVES

Adjustment

Adjust the valve close-off point by turning the "T" handle on top of the range spring housing.

When the handle is turned in (clockwise) a high bulb temperature is required to close the valve. Turn the handle ou (counterclockwise) when a lower temperature is desired.

The operator can set the valve to be fully closed at any temperature within its range. The gage on the V50B valves is an integral lpart of the temperature sensing element and helps the operator make accurate settings.

Checkout Procedure

Check for gas leaks with a soap solution at the piping connections and around valve gaskets.

Check for minimum fire stability-ifunstable use

next larger orifice from kit PLG14A-600R.

Before leaving the installation, observe at least three complete operating cycles to be sure that all components are functioning correctly. Gas pres- sure through the valve should be verified by an accurate gage.

Repairs and Replacement

The internal parts, orifice plug, diaphargms and sensing elements may be replaced. Other field repairs must not be made. When ordering a re- placement valve or sensing element, specify Product Number shown on valve. Replacement parts and valves may be obtained through the nearest Johnson Controls wholesaler.

CAUTION: Check all joints for leaks with a soap solution after valve has been repaired.

Replacement Parts

Valve Size

Valve Renewal

Diaphragm

Orifice

Kit*

Kit

Plug Kit

 

 

 

 

 

1/2*

STT15A-604R

DPM16A-600R

PLG14A-600R

 

 

 

 

3/4*

STT16A-603R

DPM16A-601R

PLG14A-600R

 

 

 

 

1*

STT17A-614R

DPM16A-602R

PLG14A-600R

 

 

 

 

1 1/4*

STT17A-615R

DPM16A-602R

PLG14A-600R

 

 

 

 

*Includes deat, disc, diaphragms and all internal parts to reconditon valve.

89

Image 89
Contents Service Manual Page Table of Contents Safety Alert Symbol Roof WARNING, Operation & SafetyRoof Damage Warning and Disclaimer Proper Use of ProductFuel Warning SafetyPower Warning Page Vane Axial Fans Previously Installed Units FAN InstallationProper Installation of the Ground Rod Machine to Earth GroundTest Station RPM Vane Axial Fan FAN SpecificationsFAN Fan Troubleshooting Chart FAN TroubleshootingPush Start Button, Nothing Happens TroubleshootingFan Control Circuit Volt 1 Phase 15 HP FAN Wiring and SchematicLubricant FAN ServiceMotors with Regreasing Grease in motor bearings84 ft. lbs. Trantorque Hub Bolt Torque Requirement for Fan Blades14 1HP 18-1.5HPCentrifugal FAN Service Guide RPM FAN RPM FAN Specifications 150 200 100 Schematic Wiring Diagram FAN Schematic and WiringVolt 1 Phase 15 HP Marathon Relubrication Intervals ProcedureLubrication 29ft. lbs. Browning 15HP 3500RPM fans 16ft. lbs. BrowningGas Heater Service Guide Operating Temperature Table Heater InstallationBin Configuration Replacing HF-7100 Board with HF-7318 Disconnectand LOCK-OUT Power Before Servicing HeaterLow Temperature Heater Specifications High Temperature Heater SpecificationsBTUs per Gauge Pressure PSI Propane Models Approximate Vane Axial GAS Heater SpecificationsBTUs Gauge Pressure PSI Natural Gas Models Approximate Low & Medium Temperature Models CHI-TOWN GAS Heater SpecificationsHigh Temperature CHI-TOWN Heater SpecificationsBtus Per Gauge Pressure Psi Natural Gas Models Approximate MED TemperatureCentrifugal Heater Specifications Downwind Heater SpecificationsTransition Hi-limit Installation Air Pressure Switch Temperature Sensor Box InstallationSecondary Heater Unit Heater Unit WiringFigure a Installing Optional Humidity SensorPower Up Operating ProcedureNormal Operating Displays With Heater Not Running Starting The Dryer Setting Gas PressureOperating Procedure Adjusting the Air Pressure Switch AIR Pressure SwitchRunning The Dryer Adjusting The VaporizorProgramming Set Points Programming Hours To Shutdown Drying Grain Hours To Shutdown ModeRun Hours Display Multiple Heater NotesAmount of gas used by the heater Modulating Valve OperationAt GSI Factory ConfigurationConfiguration Dip Switches Normally Done Limit Switches Error ConditionsMultiple Heater Error Conditions Misc Error NumbersHeater Service Wiring Diagram Programing Instructions for Series 2000 Heater Turn Control Power on dryer to the off positionProgrammer Hook Up +18%Connect power cord to fan control box Heater Electrical InstallationHeater Electrical Installation 230V Fans Mount the housing to the bin Sidewall to seal Transition HI-LIMIT InstallationPlenum Thermostat Mounting To the right sideAnnual Heater Inspection Installation For Standard Units For Units Using HF-7318 Control BoardRun 2 wires 18 gage between master and slave unit FAN PartsWiring Schematic Standard Heater Wiring Standard Heater Schematic Housing TROUBLE-SHOOTING Flow Chart7528% 352%$%/&$86 Trouble Shooting ChartFan and Heater Gas Heaters Deluxe Heater Wiring Deluxe Heater Schematic Heaters Installation HI-LO Units 2ND Heater InstallationInstallation Standard Units HI-LO Fire Heater Smart BoardStandard Heaters not HI-LO fire Description Troubleshooting ChartLight Identification For Heaters Manufactured after Fan And Heater Downwind Heat Adjustment ProcedureGAS Heaters 2ND Heater Installation Wiring Schematic GAS Heaters Purge Delay Electrical CHECK-OUT ChartTime Delay Reset Flame Probe2ND Heater Installation PRE-1990 GAS Heaters Heater Wiring Diagram Vane Axial LP Heater Heater SchematicVane Axial Vapor Heater Downwind LP Heater Downwind Vapor Heater Lo-Fire Downwind Heater Miscellaneous Information Part Number HF-7136 Flame Detector KIT Installation1991-1993PNEG-286 Flame Detector Kit Installation 1994-1995PNEG-286 Flame Detector Kit Installation PRESENTPNEG-286 SELF-OPERATED Modulating Valves InstallationApplication OperationOrifice Sizes in Kit Number PLG14A-600R Bypass Orifice SelectionCheckout Procedure AdjustmentRepairs and Replacement Replacement PartsManual Reset Installation InstructionsFENWAL-SERIES SeriesFlame Sensing SpecificationsElectrode Application Control Board CommentsSystem Checks Fan and Heater Control BoardPolarity Check Initial OperationFENWAL-SERIES Repair and Replacements Safety ChecksTwisto Says WARRANTY/SERVICE NotesLimited Warranty Statement Motor Capacitor Chart Page 1004 E. Illinois St Assumption, IL Phone Fax February