Burnham IN10 manual Pilot Burner, Honeywell Q348A1002

Page 79

Key

Description

Part No.

 

 

 

 

Quantity

 

 

 

 

No.

IN3

IN4

IN5

IN6

IN7

IN8

IN9

IN10

IN11

IN12

 

 

5. Pilot Burner and Gas Valve, Intermittent Ignition (EI), Natural Gas

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5A

Pilot Burner, Honeywell Q348A1002

8236072

1

1

1

1

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

5B

Pilot Orifice, Honeywell 388146NE

Included

1

1

1

1

1

1

1

1

1

1

with 5A

 

 

 

 

 

 

 

 

 

 

 

 

5C

Compression Nut/Fitting, 1/4" OD x 1/4

8236109

2

2

2

2

2

2

2

2

2

2

C.C. (Included with 5A and 5E)

 

 

 

 

 

 

 

 

 

 

 

 

5D

Pilot Tubing, 1/4" OD x 30"

8236122

1

1

1

1

1

---

---

---

---

---

 

 

 

 

 

 

 

 

 

 

 

 

Pilot Tubing, 1/4" OD x 40"

8236123

---

---

---

---

---

1

1

1

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5E

Gas Valve, Honeywell VR8204C3007

81660145

1

1

1

1

---

---

---

---

---

---

 

 

 

 

 

 

 

 

 

 

 

 

Gas Valve, Honeywell VR8304P4306

81660161

---

---

---

---

1

1

1

1

1

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5F

Igniter/Sensor Cable, 36", Honeywell

8236084

1

1

1

1

1

1

1

1

1

1

394800-36

 

 

 

 

 

 

 

 

 

 

 

 

5G

Ground Wire Assembly

6136054

1

1

1

1

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

5. Pilot Burner and Gas Valve, Intermittent Ignition (EI), LP/Propane

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5A

Pilot Burner, Honeywell Q348A1010

8236081

1

1

1

1

1

1

1

---

---

---

 

 

 

 

 

 

 

 

 

 

 

 

 

5B

Pilot Orifice, Honeywell 388146KP

Included

1

1

1

1

1

1

1

---

---

---

with 5A

 

 

 

 

 

 

 

 

 

 

 

 

5C

Compression Nut/Fitting, 1/4" OD x 1/4

8236109

2

2

2

2

2

2

2

---

---

---

C.C. (Included with 5A and 5E)

 

 

 

 

 

 

 

 

 

 

 

 

5D

Pilot Tubing, 1/4" OD x 30"

8236122

1

1

1

1

1

---

---

---

---

---

 

 

 

 

 

 

 

 

 

 

 

 

Pilot Tubing, 1/4" OD x 40"

8236123

---

---

---

---

---

1

1

---

---

---

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5E

Gas Valve, Honeywell VR8204C3015

81660146

1

1

1

1

---

---

---

---

---

---

 

 

 

 

 

 

 

 

 

 

 

 

Gas Valve, Honeywell VR8304P4314

81660160

---

---

---

---

1

1

1

---

---

---

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5F

Igniter/Sensor Cable, 36" Honeywell

8236084

1

1

1

1

1

1

1

---

---

---

394800-36

 

 

 

 

 

 

 

 

 

 

 

 

5G

Ground Wire Assembly

6136054

1

1

1

1

1

1

1

---

---

---

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: Gas Valve specifications shown for normal altitude (0-2000 feet). For High Altitude consult factory.

79

Image 79
Contents 8141049R26-10/08 Price $5.00 IndependencePage Page Dimensional Drawing Table of Contents Probe L.W.C.O Float L.W.C.O Tankless Heater Pre-Installation Clearance to Combustible Materials Install Base-Burner-Manifold Assembly II. Knocked-Down Boiler AssemblyInstall assembled cast iron sections on base assembly Canopy Gasket Installation Install CanopyCombustion Chamber Intermittent Ignition EI Install Ignition Module Install Blocked Vent Switch with sheet metal screwsSteam Boiler with Probe Low Water Cutoff III. Semi-Pak Boiler AssemblyInstall Trim and Controls Remove CrateWater Boiler Junction Box and Mounting Bracket AssemblyInstall Jacket Front Panel IV. Packaged Boiler AssemblyRemove Jacket Front Panel. See Figure Piping and Trim Page Recommended Water Piping for Circulator Zoned Heating System Recommended Water Piping for Zone Valve Zoned Heating System Recommended Piping for Indirect Water Heater Page Rated Input VI. Gas PipingConnect boiler gas valve to gas supply system Specific Gravity Correction Factors for Natural Gas Fitting Equivalent LengthsBoiler Equipped With Vent Damper VII. VentingIf an Existing Boiler is Removed Typical Vent InstallationVIII. Electrical Wire Vent Damper if usedAlliance Indirect Water Heater if used Thermostat Heat Anticipator SettingsVent Damper Harness to Limit This page Left Intentionally Blank Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Follow Lighting or Operating Instructions IX. System Start-upFill boiler with water Prepare to check operationPage Page Page Page Ignition Module Terminal Cross-Reference Ignition Module Wiring Ladder Diagram Terminal DesignationOFF Green LED Status CodesPilot Burner Flame, Honeywell Q350 Check Limit Adjust gas input rate to boiler. Natural GasCheck low water cutoff steam only Do not drain below gauge glassInput Rate Adjust gas input rate to boiler. LP/PropanePage Page Maintenance of Low Water Cutoff Service InstructionsClean Boiler Flueways Boiler Flueway CleaningTankless Heater Pilot Burner LocationModel No Gallons Per Month Year Excessive Make-Up WaterHoneywell Electronic Ignition Trouble Shooting Guide Honeywell Hot Surface to Pilot Trouble Shooting Guide Avoid Breathing Fiber Particulates and Dust Service Record XI. Repair PartsSection Assembly Canopy and Draft Hood Canopy/Draft Hood Parts Base Tray Base AssemblyBurner Tray 1 Inch Main Burners Manifold and 1 Main Burners Manifold and Main Burners 1 Inch Main Burners Only Volt Continuous Ignition Standing Pilot Natural Gas Manifold and 40mm Main BurnersManifold and Main Burners 40MM Main Burners only Intermittent Ignition OnlyNatural Gas, High Altitude 2000-4500 Ft. Canada Only LP Gas, High Altitude 2000-5000 Ft. USA OnlyNatural Gas, High Altitude 5000-9000 Ft. USA Only LP Gas, High Altitude 5000-9000 Ft. USA OnlyPilot Burner, Honeywell Q350A1321 Pilot Burner, Honeywell Q348A1002 Page Jacket Assembly Front Top Panel Jacket Assembly Refer to Figure onSteam Trim Page Water Trim Quantity This page Left Blank Intentionally Page Ignition Module Intermittent Ignition Only Flame Rollout SwitchBlocked Vent Switch Transformer Steam and Gravity Water OnlyXII. Low Water Cut Off Lwco Wiring of Typical LwcoLwco Location Limited Warranty Limited Warranty