Burnham IN10 manual Water Trim

Page 85

Key

Description

Part No.

IN3

IN4

IN5

IN6

IN7

IN8

IN9

IN10

IN11

IN12

No.

 

 

 

 

 

 

 

 

 

 

 

 

Water Trim

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7A

Safety Relief Valve, 3/4 NPT, 30 psi,

81660363

1

1

1

1

1

1

1

1

1

1

Conbraco 10-407-05

 

 

 

 

 

 

 

 

 

 

 

 

7B

Elbow, 3/4 NPT

806601520

1

1

1

1

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

7C

Nipple, 3/4 NPT x 3"

806600002

2

2

2

2

2

2

2

2

2

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Circulator, Bell & Gossett NRF-22 with

8056174

 

 

 

 

 

 

 

 

 

 

 

Gaskets

 

 

 

 

 

 

 

 

 

 

8A

 

1

1

1

1

1

1

1

1

1

1

Circulator, Grundfos UP 15-42F

8056044

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Circulator, Taco 007

8056007

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gasket, Bell & Gossett NRF-22

806602029

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8B

Gasket, Grundfos 510179

806602016

2

2

2

2

2

2

2

2

2

2

 

Gasket, Taco '00' Series

806602006

 

 

 

 

 

 

 

 

 

 

8C

Flange, 1-1/2 NPT

806602014

2

2

2

2

2

2

2

2

2

2

8D

Screw, Cap Hex Head, 7/16 -14 x 1-1/2"

80861301

4

4

4

4

4

4

4

4

4

4

 

 

 

 

 

 

 

 

 

 

 

 

 

8E

Nut, Hex, 7/16 -14

80860406

4

4

4

4

4

4

4

4

4

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tankless Heater, A-62

6031201

---

1

1

1

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

9A

Tankless Heater, #222

6036007

---

---

1

1

1

1

1

1

1

1

Tankless Heater, A-51

6031202

---

---

---

1

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tankless Heater, A-53

6031203

---

---

---

---

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heater Cover Plate

7036001

1

1

1

1

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

9B

Gasket

8036020

1

1

1

1

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

9C

Washer, 3/8"

80860600

6

6

6

6

6

6

6

6

6

6

 

 

 

 

 

 

 

 

 

 

 

 

 

9D

Screw, Cap Hex Head, 3/8 -16 x 7/8"

80861337

6

6

6

6

6

6

6

6

6

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Limit, Honeywell L8148E1299

80160607

 

 

 

 

 

 

 

 

 

 

 

(Intermittent Circulation Only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10A

Limit, Honeywell L6081A1010

80160469

1

1

1

1

1

1

1

1

1

1

 

(Tankless Heater Only)

 

 

 

 

 

 

 

 

 

 

 

 

Limit, Honeywell L4006A2015

80160400U

 

 

 

 

 

 

 

 

 

 

 

(Gravity Circulation Only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Well, Honeywell 123871A

80160452

 

 

 

 

 

 

 

 

 

 

 

(Tankless Heater Only)

 

 

 

 

 

 

 

 

 

 

10B

 

1

1

1

1

1

1

1

1

1

1

Well, Honeywell 123870A (Intermittent or

80160426

 

Gravity Circulation Only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11A

Temperature/Pressure Gauge,

8056169U

1

1

1

1

1

1

1

1

1

1

ENFM 41042.5210

11B

Drain Valve, Conbraco 31-612-02

806603012

1

1

1

1

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

11C

Bushing, 2 NPT x 3/4 NPT

806600515

1

1

1

1

1

1

1

1

1

1

12

Transformer, 50VA, Honeywell AT150D1019

80160186

1

1

1

1

1

1

1

1

1

1

(Tankless Heater or Gravity Circulation Only)

 

 

 

 

 

 

 

 

 

 

 

 

13

Relay, DPST, Honeywell R8225D1029

80160265

1

1

1

1

1

1

1

1

1

1

(Tankless Heater Only)

 

 

 

 

 

 

 

 

 

 

 

 

14

Relay, SPST, Honeywell R8222K1000

80160127

1

1

1

1

1

1

1

1

1

1

(Gravity Circulation Only)

 

 

 

 

 

 

 

 

 

 

 

 

85

Image 85
Contents 8141049R26-10/08 Price $5.00 IndependencePage Page Dimensional Drawing Table of Contents Probe L.W.C.O Float L.W.C.O Tankless Heater Pre-Installation Clearance to Combustible Materials Install Base-Burner-Manifold Assembly II. Knocked-Down Boiler AssemblyInstall assembled cast iron sections on base assembly Canopy Gasket Installation Install CanopyCombustion Chamber Intermittent Ignition EI Install Ignition Module Install Blocked Vent Switch with sheet metal screwsInstall Trim and Controls III. Semi-Pak Boiler AssemblyRemove Crate Steam Boiler with Probe Low Water CutoffWater Boiler Junction Box and Mounting Bracket AssemblyInstall Jacket Front Panel IV. Packaged Boiler AssemblyRemove Jacket Front Panel. See Figure Piping and Trim Page Recommended Water Piping for Circulator Zoned Heating System Recommended Water Piping for Zone Valve Zoned Heating System Recommended Piping for Indirect Water Heater Page Rated Input VI. Gas PipingConnect boiler gas valve to gas supply system Specific Gravity Correction Factors for Natural Gas Fitting Equivalent LengthsBoiler Equipped With Vent Damper VII. VentingIf an Existing Boiler is Removed Typical Vent InstallationVIII. Electrical Wire Vent Damper if usedAlliance Indirect Water Heater if used Thermostat Heat Anticipator SettingsVent Damper Harness to Limit This page Left Intentionally Blank Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Fill boiler with water IX. System Start-upPrepare to check operation Follow Lighting or Operating InstructionsPage Page Page Page Ignition Module Terminal Cross-Reference Ignition Module Wiring Ladder Diagram Terminal DesignationOFF Green LED Status CodesPilot Burner Flame, Honeywell Q350 Check low water cutoff steam only Adjust gas input rate to boiler. Natural GasDo not drain below gauge glass Check LimitInput Rate Adjust gas input rate to boiler. LP/PropanePage Page Maintenance of Low Water Cutoff Service InstructionsClean Boiler Flueways Boiler Flueway CleaningTankless Heater Pilot Burner LocationModel No Gallons Per Month Year Excessive Make-Up WaterHoneywell Electronic Ignition Trouble Shooting Guide Honeywell Hot Surface to Pilot Trouble Shooting Guide Avoid Breathing Fiber Particulates and Dust Service Record XI. Repair PartsSection Assembly Canopy and Draft Hood Canopy/Draft Hood Parts Base Tray Base AssemblyBurner Tray 1 Inch Main Burners Manifold and 1 Main Burners Manifold and Main Burners 1 Inch Main Burners Only Manifold and Main Burners 40MM Main Burners only Manifold and 40mm Main BurnersIntermittent Ignition Only Volt Continuous Ignition Standing Pilot Natural GasNatural Gas, High Altitude 5000-9000 Ft. USA Only LP Gas, High Altitude 2000-5000 Ft. USA OnlyLP Gas, High Altitude 5000-9000 Ft. USA Only Natural Gas, High Altitude 2000-4500 Ft. Canada OnlyPilot Burner, Honeywell Q350A1321 Pilot Burner, Honeywell Q348A1002 Page Jacket Assembly Front Top Panel Jacket Assembly Refer to Figure onSteam Trim Page Water Trim Quantity This page Left Blank Intentionally Page Blocked Vent Switch Flame Rollout SwitchTransformer Steam and Gravity Water Only Ignition Module Intermittent Ignition OnlyXII. Low Water Cut Off Lwco Wiring of Typical LwcoLwco Location Limited Warranty Limited Warranty