Burnham IN10 manual Steam Trim

Page 83

Key

Description

Part No.

Quantity

No.

 

 

 

Steam Trim

 

 

 

 

 

 

7A

Safety Valve, 3/4 NPT, 15 psi, Conbraco 13-511-08

81660530

1

 

 

 

 

7B

Elbow, 3/4 NPT

806601502

2

 

 

 

 

7C

Nipple, 3/4 NPT x 3"

806600002

2

 

 

 

 

 

Low Water Cutoff, McDonnell & Miller PS-802-24 (Probe Included)

80160720

 

8A

Low Water Cutoff, Hydrolevel CG400-2090 (Less Probe - See Key No. 8B)

80160725

1

 

Low Water Cutoff, McDonnell & Miller 67-BC-1 (Float Type)

80160517

 

8B

Probe for CG400

80160629

1

 

 

 

 

9

Gauge Glass, Extended Shank (with Probe LWCO Only)

8056128

1

 

 

Gauge Glass, Standard Shank (with Float LWCO Only)

8056020

 

 

 

 

 

 

10A

Limit, Honeywell L404F1367

80160369

1

 

 

 

 

10B

Syphon, 1/4 NPT x 90°

806603010

1

 

 

 

 

10C

Bushing, 3/4 NPT x 1/4 NPT

806600508

1

10D

Syphon, 1/4 NPT x 180°

806603030

1

 

 

 

 

11A

Pressure Gauge

8056010

1

 

 

 

 

11B

Drain Valve, Conbraco 31-612-02

806603012

1

 

 

 

 

11C

Bushing, 2 NPT x 3/4 NPT

806600515

1

83

Image 83
Contents 8141049R26-10/08 Price $5.00 IndependencePage Page Dimensional Drawing Table of Contents Probe L.W.C.O Float L.W.C.O Tankless Heater Pre-Installation Clearance to Combustible Materials Install assembled cast iron sections on base assembly II. Knocked-Down Boiler AssemblyInstall Base-Burner-Manifold Assembly Canopy Gasket Installation Install CanopyCombustion Chamber Intermittent Ignition EI Install Ignition Module Install Blocked Vent Switch with sheet metal screwsSteam Boiler with Probe Low Water Cutoff III. Semi-Pak Boiler AssemblyInstall Trim and Controls Remove CrateWater Boiler Junction Box and Mounting Bracket AssemblyRemove Jacket Front Panel. See Figure IV. Packaged Boiler AssemblyInstall Jacket Front Panel Piping and Trim Page Recommended Water Piping for Circulator Zoned Heating System Recommended Water Piping for Zone Valve Zoned Heating System Recommended Piping for Indirect Water Heater Page Connect boiler gas valve to gas supply system VI. Gas PipingRated Input Specific Gravity Correction Factors for Natural Gas Fitting Equivalent LengthsBoiler Equipped With Vent Damper VII. VentingIf an Existing Boiler is Removed Typical Vent InstallationVIII. Electrical Wire Vent Damper if usedAlliance Indirect Water Heater if used Thermostat Heat Anticipator SettingsVent Damper Harness to Limit This page Left Intentionally Blank Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Follow Lighting or Operating Instructions IX. System Start-upFill boiler with water Prepare to check operationPage Page Page Page Ignition Module Terminal Cross-Reference Ignition Module Wiring Ladder Diagram Terminal DesignationOFF Green LED Status CodesPilot Burner Flame, Honeywell Q350 Check Limit Adjust gas input rate to boiler. Natural GasCheck low water cutoff steam only Do not drain below gauge glassInput Rate Adjust gas input rate to boiler. LP/PropanePage Page Maintenance of Low Water Cutoff Service InstructionsClean Boiler Flueways Boiler Flueway CleaningTankless Heater Pilot Burner LocationModel No Gallons Per Month Year Excessive Make-Up WaterHoneywell Electronic Ignition Trouble Shooting Guide Honeywell Hot Surface to Pilot Trouble Shooting Guide Avoid Breathing Fiber Particulates and Dust Service Record XI. Repair PartsSection Assembly Canopy and Draft Hood Canopy/Draft Hood Parts Base Tray Base AssemblyBurner Tray 1 Inch Main Burners Manifold and 1 Main Burners Manifold and Main Burners 1 Inch Main Burners Only Volt Continuous Ignition Standing Pilot Natural Gas Manifold and 40mm Main BurnersManifold and Main Burners 40MM Main Burners only Intermittent Ignition OnlyNatural Gas, High Altitude 2000-4500 Ft. Canada Only LP Gas, High Altitude 2000-5000 Ft. USA OnlyNatural Gas, High Altitude 5000-9000 Ft. USA Only LP Gas, High Altitude 5000-9000 Ft. USA OnlyPilot Burner, Honeywell Q350A1321 Pilot Burner, Honeywell Q348A1002 Page Jacket Assembly Front Top Panel Jacket Assembly Refer to Figure onSteam Trim Page Water Trim Quantity This page Left Blank Intentionally Page Ignition Module Intermittent Ignition Only Flame Rollout SwitchBlocked Vent Switch Transformer Steam and Gravity Water OnlyLwco Location Wiring of Typical LwcoXII. Low Water Cut Off Lwco Limited Warranty Limited Warranty