Bryan Boilers & 300, Triple-Flex 150, 250, 200 service manual Ilk

Page 38

263-

RESERVED

 

 

 

271

 

 

 

 

 

 

 

 

 

272

Abnormal

Recycle: Pressure sensor

fault

 

 

 

 

 

 

 

 

 

 

 

273

Abnormal Recycle: Safety relay drive

test failed

 

 

 

 

 

 

 

 

 

274

Abnormal

Recycle:

Demand

off

during

Pilot

Flame

Establishing

 

Period

 

 

 

 

 

275

Abnormal Recycle: LCI off during

Drive to Purge Rate

 

 

 

 

 

276

Abnormal Recycle: LCI off during

Measured Purge Time

 

 

 

 

 

277

Abnormal Recycle: LCI off during

Drive to Lightoff Rate

 

 

 

 

 

278

Abnormal Recycle: LCI off during

Pre-Ignition test

 

 

 

 

 

 

 

279

Abnormal Recycle: LCI off during

Pre-Ignition time

 

 

 

 

 

 

 

280

Abnormal Recycle: LCI off during

Main Flame Establishing Period

 

 

 

281

Abnormal Recycle: LCI off during

Ignition period

 

 

 

 

 

 

 

282

Abnormal

Recycle:

Demand

off

during Drive to Purge Rate

 

 

 

283

Abnormal

Recycle:

Demand

off

during Measured Purge Time

 

 

 

284

Abnormal

Recycle:

Demand

off

during Drive to Lightoff Rate

 

 

 

285

Abnormal

Recycle:

Demand

off

during Pre-Ignition test

 

 

 

 

 

286

Abnormal

Recycle:

Demand

off

during Pre-Ignition time

 

 

 

287

Abnormal Recycle: Flame was on

during Safe Start check

 

 

 

288

Abnormal Recycle: Flame was on

during Drive to Purge Rate

 

 

 

289

Abnormal Recycle: Flame was on

during Measured Purge Time

 

 

 

290

Abnormal Recycle: Flame was on

during Drive to Lightoff Rate

 

 

 

291

Abnormal Recycle: Flame was not on

at end of Ignition period

 

 

 

292

Abnormal Recycle: Flame was lost

during

Main

Flame

Establishing

 

Period

 

 

 

 

 

293

Abnormal Recycle: Flame was lost

early in Run

 

 

 

 

 

 

 

294

Abnormal Recycle: Flame was lost

during Run

 

 

 

 

 

 

 

295

Abnormal

Recycle:

Leakage

test

failed

 

 

 

 

 

 

 

 

 

 

 

296

Abnormal

Recycle: Interrupted

air

flow switch was off during Drive to

 

Purge Rate

 

 

 

Date: 8-4-2010

Revision: 0

Form: 2396

Abnormal Recycle: Interrupted air

297flow switch was off during Measured Purge Time

Abnormal Recycle: Interrupted air

298flow switch was off during Drive to Lightoff Rate

Abnormal Recycle: Interrupted air

299flow switch was off during Pre-Ignition test

Abnormal Recycle: Interrupted air

300flow switch was off during Pre-Ignition time

Abnormal Recycle: Interrupted air

301flow switch was off during Main Flame Establishing Period

302

Abnormal Recycle: Ignition failed due

to interrupted air flow switch was off

 

303

Abnormal

Recycle:

ILK

off

during

Drive to Purge Rate

 

 

 

 

 

 

 

 

 

304

Abnormal

Recycle:

ILK

off

during

Measured Purge Time

 

 

 

 

 

 

 

305

Abnormal

Recycle:

ILK

off

during

Drive to Lightoff Rate

 

 

 

 

 

 

 

 

 

306

Abnormal Recycle: ILK off during Pre-

Ignition test

 

 

 

 

 

 

 

 

 

 

 

307

Abnormal Recycle: ILK off during Pre-

Ignition time

 

 

 

 

 

 

 

 

 

308

Abnormal

Recycle:

ILK

off

during

Main Flame Establishing Period

 

 

 

309

Abnormal

Recycle:

ILK

off

during

Ignition period

 

 

 

 

 

 

 

 

 

310

Run was terminated due to ILK was

off

 

 

 

 

 

 

 

 

 

 

 

311

Run was

terminated

due

to

interrupted air flow switch was off

 

 

 

312

Stuck reset switch

 

 

 

 

313

Run was terminated due to fan failure

314

Abnormal Recycle: Fan failed during

Drive to Purge Rate

 

 

 

 

 

 

 

 

 

315

Abnormal Recycle: Fan failed during

Measured Purge Time

 

 

 

 

 

 

 

316

Abnormal Recycle: Fan failed during

Drive to Lightoff Rate

 

 

 

 

 

 

 

 

 

317

Abnormal Recycle: Fan failed during

Pre-Ignition test

 

 

 

 

 

 

 

 

 

318

Abnormal Recycle: Fan failed during

Pre-Ignition time

 

 

 

 

 

 

 

 

 

319

Abnormal Recycle: Fan failed during

Ignition period

 

 

 

 

 

 

 

 

 

320

Abnormal Recycle: Fan failed during

Main Flame Establishing Period

 

 

 

321

Abnormal Recycle: Main

Valve

off

after 10 seconds of RUN

 

 

 

 

 

 

 

322

Abnormal Recycle:

Pilot

Valve

off

after 10 seconds of RUN

 

 

 

 

 

 

 

32

Image 38
Contents Triple-Flex High Efficiency Boilers Triple-Flex 150, 200, 250 High Efficiency Boilers Table of Contents Lead Drop-Stage On Error Ldse Figures Date Date Revision Form Minimum Clearances to Combustible Surfaces Boiler FoundationClearances DIMFlow Connection Safety Relief ValvesBoiler Connections Expansion Tank ConnectionsKW HP Venting of GAS Train ComponentsElectrical Requirements Combustion AIR SupplyCombustion AIR Openings LOUVERS, GRILLES, and ScreensDesign & Installation Flue GAS Venting SystemCombustion AIR and Venting Requirements for Canada ScfmMarking of GAS Vents Before Placing Boiler in OperationHydrostatic Test of Boilers and System Test of GAS PipingStart-Up and Operation Triple-Flex High Efficiency Boilers Boiler Assembly TRIPLE-FLEX Front ViewTRIPLE-FLEX Rear View Triple-Flex Rear ViewTRIPLE-FLEX Behind the Cabinet Door TRIPLE-FLEX Left Side ViewTRIPLE-FLEX Right Side View Air Flow Switch Pilot Spark Igniter Assembly TRIPLE-FLEX Left Flue Collector ViewHome POWER-UP ValidationTRIPLE-FLEX Right Flue Collector View Sola Hydronic Control SystemNavigation KeyboardConfiguration Configure StatusConfiguration Password Sample ConfigurationChange Parameter Settings Safety Verification Configure VerifyFAULT/ALARM Handling Safety Parameter User ConfirmationInfo BAR Lockouts Clear Lockout Operation Home Page LockoutFiring Rate Control Operation Firing Rate Field Modulation Configuration Configure ModulationAnnunciation Operation Calibrate Touch Screen Setup Advanced Setup Diagnostics Advanced Setup Setup Advanced SetupSystem Time Setup Advanced Setup Date & Time Outdoor Reset Configure Reset / Reboot DisplayAdvanced Setup Display Reset Safety Verification Configure CH Central Heat Configuration Configure Sensor ConfigurationConfigure CH Central Heat Configuration Sound Pressure Levels PIDSound Pressure Readings Modbus Communication Alert CodesRPM DHWODR ILK HFS SLOA2D PIIRevision Boiler Commissioning Test SetupPRE Checks and Setup ModulationPilot Adjustment DRY RUNInitial Light OFF Adjusting Boiler Maximum InputAdjusting Boiler Minimum Input IWCCFH = 3600Vc gc CFH = ft 3 hr −1 of gas Vc = ft clocked GAS Meter ReadingsTroubleshooting PII Or LDate ILK OFF LCI OFFPII OFF ILK on Vsnsr WeakOFF Fault CodesAre OEM Specific Fault Codes ThroughOFF Blower LCI High Limit setpoint setting 228 Invalid Reserved Care and Maintenance Boil OUT Procedure Boiler Water Treatment Draining the SystemDo not Flush the System Through the Boiler External FIRE-SIDE Cleaning Suggested Maintenance ScheduleDate Revision Form Lead Lag General Description of the Lead LAG Application Lead LAG LL Master General OperationDrop-stage method Drop-stage detection timing System Wiring Hookup LL / Multi-Boiler Field WiringLEAD-LAG Operation Slave Parameters Slave Operation and SetupSlave Mode USE FIRST, Equalize RUNTIME, USE Last LL Master Operation and Setup Overall ControlPeriodic Data Polling Messages Slave Status ManagerAbnormalFaultCounter Used to tolerate momentary abnormality Invalid Response or no ResponseLL CH Demand Switch DISABLE, STAT, Environcom Remote Stat Master Heat DemandModulation Sensor Master Active ServiceMaster Service Status LL Modulation Sensor S5Demand and Rate Implementation Rate AdjustmentIntegrator Compensation Rate Allocation Method Parallel Commonbase Limited Rate AllocationBase Load Common 0-100% Modulating Stage Overflow and UnderflowStagerstate = Active Burner DemandStagerstate = Idle ADD-STAGE Rate Offset -100% to +100% ADD-STAGE Error Threshold DegreesError Threshold ADD-STAGE ConditionDROP-STAGE Rate Offset -100% to +100% DROP-STAGE Error Threshold DegreesLL ALL Boilers OFF Threshold Temperature or None DROP-STAGE ConditionForce Lead Rotation Time Hhmm or None Lead DROP-STAGE on ErrorLAG Selecton Method Sequence ORDER, Measured RUN Time Date Revision Form Slave Write Data Sequencer 1 Minute EventForced Lead Rotation Slave Read Data