Bryan Boilers 200, Triple-Flex 150, 250, & 300 service manual Slo, A2D, Hfs, Pii, Pid

Page 39

323

Abnormal Recycle: Safety Relay off

after 10 seconds of RUN

 

 

 

 

 

 

 

324

Abnormal

Recycle: Hardware

flame

bias

 

 

 

 

 

 

 

 

 

 

 

325

Abnormal

Recycle: Hardware

static

flame

 

 

 

 

 

 

 

 

 

 

 

326

Abnormal

Recycle: Hardware

flame

current invalid

 

 

 

 

 

 

 

 

 

327

Abnormal

Recycle: Hardware

flame

rod short

 

 

 

 

 

 

 

 

 

 

 

328

Abnormal Recycle: Hardware invalid

power

 

 

 

 

 

 

 

 

 

 

 

329

Abnormal Recycle: Hardware invalid

AC line

 

 

 

 

 

 

 

 

 

 

 

330

Abnormal

Recycle: Hardware

 

SLO

flame ripple

 

 

 

 

 

 

 

 

 

331

Abnormal

Recycle: Hardware

 

SLO

flame sample

 

 

 

 

 

 

 

 

 

332

Abnormal

Recycle: Hardware

 

SLO

flame bias range

 

 

 

 

 

 

 

 

 

333

Abnormal

Recycle: Hardware

 

SLO

flame bias heat

 

 

 

 

 

 

 

 

 

334

Abnormal

Recycle: Hardware

 

SLO

spark stuck

 

 

 

 

 

 

 

 

 

335

Abnormal

Recycle: Hardware

 

SLO

spark changed

 

 

 

 

 

 

 

 

 

336

Abnormal

Recycle: Hardware

 

SLO

static flame

 

 

 

 

 

 

 

 

 

337

Abnormal

Recycle: Hardware

 

SLO

rod shorted

 

 

 

 

 

 

 

 

 

338

Abnormal

Recycle: Hardware

 

SLO

AD linearity

 

 

 

 

 

 

 

 

 

339

Abnormal

Recycle: Hardware

 

SLO

bias not set

 

 

 

 

 

 

 

 

 

340

Abnormal

Recycle: Hardware

 

SLO

bias shorted

 

 

 

 

 

 

 

 

 

341

Abnormal

Recycle: Hardware

 

SLO

electronics

 

 

 

 

 

 

 

 

 

 

 

342

Abnormal

Recycle:

Hardware

processor clock

 

 

 

 

 

 

 

 

 

343

Abnormal

Recycle:

Hardware

AC

phase

 

 

 

 

 

 

 

 

 

 

 

344

Abnormal

Recycle:

Hardware

 

A2D

mismatch

 

 

 

 

 

 

 

 

 

 

 

345

Abnormal Recycle: Hardware VSNSR

A2D

 

 

 

 

 

 

 

 

 

 

 

346

Abnormal

Recycle:

Hardware

 

28V

A2D

 

 

 

 

 

 

 

 

 

 

 

347

Abnormal

Recycle: Hardware

 

HFS

IAS shorted

 

 

 

 

 

 

 

 

 

348

Abnormal

Recycle:

Hardware

PII

INTLK shorted

 

 

 

 

 

 

 

 

 

349

Abnormal

Recycle: Hardware

 

HFS

LCI shorted

 

 

 

 

 

 

 

 

 

 

 

 

Date:

 

8-4-2010

 

 

 

Revision:

0

 

 

 

 

Form:

 

2396

 

 

 

 

350

Abnormal

Recycle: Hardware

HFS

LFS shorted

 

 

 

 

 

 

 

 

 

351

Abnormal

Recycle:

Invalid

zero

crossing

 

 

 

 

 

 

 

 

 

 

 

 

 

352

Abnormal Recycle: fault stack sensor

353

Abnormal Recycle: stack limit

 

354

Abnormal Recycle: delta T limit

 

355

Abnormal Recycle: fault outlet sensor

356

Abnormal Recycle: outlet high limit

357

Abnormal Recycle: fault DHW sensor

358

Abnormal Recycle: DHW high limit

359

Abnormal Recycle: fault inlet sensor

360

Abnormal

Recycle:

Check

Parameters Failed

 

 

 

 

 

 

 

 

 

361

Internal error: No factory parameters

were detected in control

 

 

 

 

 

 

 

362

Internal error: PID iteration frequency

was invalid

 

 

 

 

 

 

 

 

 

 

 

363

Internal

error: Demand-Rate interval

time was invalid

 

 

 

 

 

 

 

 

 

364

Internal

error: Factory

calibration

parameter for modulation was invalid

 

365

Internal error: CH PID P-scaler was

invalid

 

 

 

 

 

 

 

 

 

 

 

 

 

366

Internal

error: CH

PID

I-scaler

was

invalid

 

 

 

 

 

 

 

 

 

 

 

 

 

367

Internal error: CH PID D-scaler was

invalid

 

 

 

 

 

 

 

 

 

 

 

 

 

368

Internal error: DHW PID P-scaler was

invalid

 

 

 

 

 

 

 

 

 

 

 

 

 

369

Internal error: DHW PID I-scaler was

invalid

 

 

 

 

 

 

 

 

 

 

 

 

 

370

Internal error: DHW PID D-scaler was

invalid

 

 

 

 

 

 

 

 

 

 

 

 

 

371

Internal error: Lead Lag master PID

P-scaler was invalid

 

 

 

 

 

 

 

 

 

372

Internal error: Lead Lag master PID I-

scaler was invalid

 

 

 

 

 

 

 

 

 

373

Internal error: Lead Lag master PID

D-scaler was invalid

 

 

 

 

 

 

 

 

 

374-

RESERVED

 

 

 

 

459

 

 

 

 

 

 

 

 

 

 

 

460

LCI demand lost in run

 

 

 

461

Demand lost in run

 

 

 

 

462

STAT demand lost in run

 

 

463

Demand lost in run due to no flame

464-

RESERVED

 

 

 

 

466

 

 

 

 

 

 

 

 

 

 

 

467

Internal error: EEPROM write was

attempted

before

EEPROM

was

 

initialized

 

 

 

 

 

468

Internal error: EEPROM cycle count

address was invalid

 

 

 

 

 

 

 

 

 

33

Image 39
Contents Triple-Flex High Efficiency Boilers Triple-Flex 150, 200, 250 High Efficiency Boilers Table of Contents Lead Drop-Stage On Error Ldse Figures Date Date Revision Form DIM Boiler FoundationClearances Minimum Clearances to Combustible SurfacesExpansion Tank Connections Safety Relief ValvesBoiler Connections Flow ConnectionCombustion AIR Supply Venting of GAS Train ComponentsElectrical Requirements KW HPLOUVERS, GRILLES, and Screens Combustion AIR OpeningsFlue GAS Venting System Design & InstallationScfm Combustion AIR and Venting Requirements for CanadaBefore Placing Boiler in Operation Marking of GAS VentsTest of GAS Piping Hydrostatic Test of Boilers and SystemStart-Up and Operation Triple-Flex High Efficiency Boilers TRIPLE-FLEX Front View Boiler AssemblyTriple-Flex Rear View TRIPLE-FLEX Rear ViewTRIPLE-FLEX Left Side View TRIPLE-FLEX Right Side ViewTRIPLE-FLEX Behind the Cabinet Door Air Flow Switch TRIPLE-FLEX Left Flue Collector View Pilot Spark Igniter AssemblySola Hydronic Control System POWER-UP ValidationTRIPLE-FLEX Right Flue Collector View HomeKeyboard NavigationStatus Configuration ConfigureSample Configuration Configuration PasswordSafety Verification Configure Verify Change Parameter SettingsSafety Parameter User Confirmation FAULT/ALARM HandlingHome Page Lockout Info BAR Lockouts Clear Lockout OperationModulation Configuration Configure Modulation Annunciation OperationFiring Rate Control Operation Firing Rate Field Advanced Setup Setup Advanced Setup System Time Setup Advanced Setup Date & TimeCalibrate Touch Screen Setup Advanced Setup Diagnostics Reset / Reboot Display Advanced Setup Display ResetOutdoor Reset Configure Configure Sensor Configuration Configure CH Central Heat ConfigurationSafety Verification Configure CH Central Heat Configuration PID Sound Pressure LevelsSound Pressure Readings Alert Codes Modbus CommunicationDHW RPMODR ILK PII SLOA2D HFSRevision Modulation Test SetupPRE Checks and Setup Boiler CommissioningDRY RUN Pilot AdjustmentIWC Adjusting Boiler Maximum InputAdjusting Boiler Minimum Input Initial Light OFFGAS Meter Readings CFH = 3600Vc gc CFH = ft 3 hr −1 of gas Vc = ft clockedPII Or L TroubleshootingDate LCI OFF PII OFFILK OFF ILK on Weak VsnsrThrough Fault CodesAre OEM Specific Fault Codes OFFOFF Blower LCI High Limit setpoint setting 228 Invalid Reserved Care and Maintenance Boil OUT Procedure Draining the System Do not Flush the System Through the BoilerBoiler Water Treatment Suggested Maintenance Schedule External FIRE-SIDE CleaningDate Revision Form Lead Lag Lead LAG LL Master General Operation General Description of the Lead LAG ApplicationDrop-stage method Drop-stage detection timing LL / Multi-Boiler Field Wiring System Wiring HookupLEAD-LAG Operation Slave Operation and Setup Slave Mode USE FIRST, Equalize RUNTIME, USE LastSlave Parameters Overall Control LL Master Operation and SetupSlave Status Manager Periodic Data Polling MessagesInvalid Response or no Response AbnormalFaultCounter Used to tolerate momentary abnormalityMaster Heat Demand LL CH Demand Switch DISABLE, STAT, Environcom Remote StatLL Modulation Sensor S5 Master Active ServiceMaster Service Status Modulation SensorDemand and Rate Rate Adjustment Integrator CompensationImplementation Rate Allocation Base Load Common 0-100%Rate Allocation Method Parallel Commonbase Limited Overflow and Underflow Modulating StageBurner Demand Stagerstate = IdleStagerstate = Active ADD-STAGE Condition ADD-STAGE Error Threshold DegreesError Threshold ADD-STAGE Rate Offset -100% to +100%DROP-STAGE Condition DROP-STAGE Error Threshold DegreesLL ALL Boilers OFF Threshold Temperature or None DROP-STAGE Rate Offset -100% to +100%Lead DROP-STAGE on Error LAG Selecton Method Sequence ORDER, Measured RUN TimeForce Lead Rotation Time Hhmm or None Date Revision Form Slave Read Data Sequencer 1 Minute EventForced Lead Rotation Slave Write Data