Hearth and Home Technologies TRUE-42 Top Vent Horizontal Termination One Elbow, TRUE-50 NG/LP

Page 27

1.Top Vent - Horizontal Termination One Elbow

WARNING! Risk of Fire!

Note: Flue restrictor is permit- ted ONLY on 30 ft. minimum vertical runs with no elbows.

TRUE-36(NG/LP), TRUE-42(NG), and TRUE-50(NG/LP) models require a minimum of 24 inches of vertical venting before attaching any elbow to the appliance.

TRUE-42(LP) model requires a minimum of 36 inches of vertical venting before attaching any elbow to the appliance.

DO NOT attach elbow directly to the appliance.

H1

V1

Figure 7.3

TRUE-36 (NG/LP), TRUE-42 (NG),

TRUE-50 (NG/LP)

V1 Minimum

H1

Maximum

2 ft

610 mm

7 in*

 

178 mm

 

 

 

 

 

3 ft

914 mm

2 ft

 

610 mm

4 ft

1.2 m

4 ft

 

1.2 m

5 ft

1.5 m

9 ft

 

2.7 m

 

 

 

 

 

6 ft

1.8 m

12 ft

 

3.7 m

7 ft

2.1 m

14 ft

 

4.3 m

10 ft

3.0 m

20 ft

 

6.1 m

 

 

 

 

 

20 ft

6.1 m

40 ft

 

12.2 m

 

 

 

 

 

After V1= 6 ft then H1 = 2 x V ft Maximum

V1 + H1 = 60 ft Maximum

*when used with approved termination caps

TRUE-42 (LP)

V1 Minimum

H1 Maximum

3 ft

914 mm

10 in.

254 mm

4 ft

1.2 m

4 ft

1.2 m

 

 

 

 

5 ft

1.5 m

9 ft

2.7 m

 

 

 

 

6 ft

1.8 m

12 ft

3.7 m

7 ft

2.1 m

14 ft

4.3 m

10 ft

3.0 m

20 ft

6.1 m

 

 

 

 

20 ft

6.1 m

40 ft

12.2 m

 

 

 

 

After V1= 6 ft then H1 = 2 x V ft Maximum

V1 + H1 = 60 ft Maximum

*when used with approved termination caps

Heat & Glo • TRUE-36, TRUE-42, TRUE-502282-900 Rev. D • 8/12

27

Image 27
Contents HOT Surfaces ModelsWhat to do if you smell gas Do DiscardnotHomeowner Reference Information CongratulationsUser Guide Table of ContentsAppliance Setup TroubleshootingReference Materials Limited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsGas Fireplace Safety Operating Instructions User GuideYour Fireplace Clear Space Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches IPI Battery Tray/Battery InstallationBefore Lighting Fireplace Module ResetNine Hour Safety Shutdown Feature Control Module OperationGAS Valve Lighting Instructions IPIFinal inspection by What to do if YOU Smell GASFrequently Asked Questions Issue SolutionsAfter Fireplace is Lit Maintenance and Service D Replacement Maintenance Tasks-Qualified Service TechnicianGlass Cleaning Exterior and Interior of Installed Glass Gasket Seal and Glass Assembly InspectionIPI Pilot Flame Patterns Burner Ignition and OperationTypical Appliance System Getting StartedAny such action may cause a fire hazard Design and Installation ConsiderationsTools and Supplies Needed Inspect Appliance and ComponentsTRUE-42 Framing and ClearancesSelecting Appliance Location TRUE-36Minimum Framing Dimensions Constructing the Appliance ChaseClearances Non-Combustible Mantel Legs or Wall Projections Mantel and Wall ProjectionsNon-Combustible Zone Combustible Mantel Legs or Wall ProjectionsTRUE-50 21 MINCombustible Mantel Projections NON-COMBUSTIBLE MaterialModel Hearth Extension Vent Termination Minimum Clearances Termination LocationsCovered Alcove Applications Ft. Canada ..........not to be installed above a gas meterVent Information and Diagrams V1 Minimum Maximum Top Vent Horizontal Termination One ElbowTRUE-36 NG/LP, TRUE-42 NG TRUE-50 NG/LPMinimum Two Elbows+ H TRUE-36 NG/LP, TRUE-42 NG/LPTRUE-36 NG/LP, TRUE-42 NG/LP, TRUE-50 NG/LP Top Vent Horizontal Termination Three ElbowsFlue Restrictor Elbows Top Vent Vertical TerminationTRUE-36 NG/LP, TRUE-42 NG/LP, TRUE-50 NG/LP Ht Max Top Vent Vertical Termination Three ElbowsPVI-SLP PVK-80 and PVI-SLP InformationNon-Combustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration FramingPipe DVP Install the Ceiling FirestopVaulted Ceiling Installation Install Attic Insulation ShieldInstalling the Optional Heat-ZoneGas Kit Flat Ceiling InstallationVent Preparation Appliance PreparationSide Nailing Tab in Shipping Position Securing and Leveling the ApplianceInstalling Non-Combustible Facing Material Installing Non-combustible Facing MaterialAssemble Pipe Sections Installing Vent Pipe DVP PipeAttach Vent to the Firebox Assembly Assemble Vent SectionsDisassemble Vent Sections Secure the Vent SectionsAssemble and Install Storm Collar Install Metal Roof FlashingInstall Vertical Termination Cap Install Horizontal Termination CapHeat Shield Requirements for Horizontal Termination Gas Connection Gas InformationFuel Conversion Gas PressureElectrical Information Wiring RequirementsIntelliFire PlusTM Ignition System Wiring Optional Accessories RequirementsAccess Through Left Column Access Through Firebox Electrical Service and Repair Junction Box InstallationTemplate installation instruction FinishingFinishing Templates Finishing Templates Bends Inoperable Fixed Doors Splatter GuardFACTORY-SUPPLIED NON-COMBUSTIBLE Combustible or Board 10 Combustible Mantel Allowance TRUE-36, TRUE-42 MAX 21 MINFacing Material 14 Non-combustible Facing DiagramOperable Doors Dimension Inoperable Operable DoorDoors ArchAppliance Setup LED’s Glowing Ember PlacementNotch for Install the Log Assembly Log Set Assembly LOGS-TRUE36Models TRUE-36C, TRUE-36H, TRUE-36S LOG Contacts Side Grate TineLOG Contacts Left Grate Tine TineLOG Contacts Grate Tine LOG #7 TRUE-42 only Back Tine LOG Contacts Refractory Notch Front TineNotch for For LOG #3 LOG Placement Slots NotchLOG #4 Flat AreaTOP of Burned Area Near LOG #1 LOG Resting in Notch LOG Contacts 8 Grate Tine Back Tine Front Tine LOG Contacts Refractory NotchTRUE-36 TRUE-42 TRUE-50 TOP Retaining Rail Notch Glass Frame Notch TRUE-50 Air Shutter SettingModel TRUE-36 TRUE-42Troubleshooting Symptom Possible Cause Corrective ActionIntelliFire Plus Ignition System Troubleshooting Appliance Dimension Diagram Reference MaterialsLocation Inches Millimeters Appliance Dimensions TRUE-42 & TRUE-50 DVP-AS2 Vent Components DiagramsDVP-TRAP1 DVP-TRAP2 DVP-TRAPK1 DVP-TRAPK2 DVP-TRAPHorizontal Termination Cap COOL-ADD RF6M RF12MBEK DVP-BEK2 DVP-TRAPFLSLP-LPC Optional Wire HarnessPower Vent Inline Description Part NumberDescription Comments Part Number Log Set AssemblyCService. ServicePartsParts At DepotService Parts StockedDescription Comments Part Number Log Set Assembly TRUE-42S, TRUE-42H, TRUE-42C LOGS-TRUE50 TRUE-50S, TRUE-50H, TRUE-50C TRUE-36, TRUE-42, TRUE-50 #13 Valve AssemblyMYSTIC-EMBERS Contact Information