H. Install the Log Assembly

Log Set Assembly: LOGS-TRUE36

LOGS-TRUE42

Models: TRUE-36C, TRUE-36H, TRUE-36S

TRUE-42C, TRUE-42H, TRUE-42S

LOG PLACEMENT TABS

TRUE-42 ONLY

NOTCH FOR LOG #6 FLAT SPOT FOR LOG #3

1

LOG PLACEMENT NOTCH

Figure 1.

Figure 2.

CAUTION: Logs are fragile, handle with care. Log #1 (2280-701 for TRUE-36,2281-701 FOR TRUE-42): Locate log placement notch on the bottom of log #1. See Figure 2. Mate outer notches on the bottom of Log #1 with the left and right grate tines. Slide Log #1 toward the rear of appliance until back side of Log #1 contacts the log placement tabs. See Figures 1-3.

1

Figure 3.

3

2

BURNED AREA

LOG PLACEMENT NOTCH

2

LOG PLACEMENT SLOTS

Figure 4.

Log #2 (2280-702 for TRUE-36,2281-702 for TRUE-42): Locate log placement notch on the bottom of Log #2. See Figure

4.Mate notch on the bottom of Log #2 with the center and right grate tines. Slide log toward rear of appliance until right end contacts the side grate tine. See Figure 5.

Log #2 (TRUE-36 ): Log #2 will be about 1 inch from the back of the center grate tine when properly placed. See Figure 5.

Log #2 (TRUE-42 ): Log #2 will contact center log placement

1

LOG CONTACTS SIDE GRATE TINE

tab on center grate tine. See Figure 5.

NOTCH FOR

LOG #3

2

LEFT SIDE TOWARD REAR

Figure 5.

Heat & Glo • TRUE-36, TRUE-42, TRUE-502282-900 Rev. D • 8/12

55

Image 55
Contents HOT Surfaces ModelsWhat to do if you smell gas Do DiscardnotHomeowner Reference Information CongratulationsUser Guide Table of ContentsTroubleshooting Appliance SetupReference Materials Limited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsOperating Instructions User Guide Gas Fireplace SafetyYour Fireplace Clear Space Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches IPI Battery Tray/Battery InstallationBefore Lighting Fireplace Module ResetNine Hour Safety Shutdown Feature Control Module OperationGAS Valve Lighting Instructions IPIFinal inspection by What to do if YOU Smell GASIssue Solutions Frequently Asked QuestionsAfter Fireplace is Lit Maintenance and Service D Replacement Maintenance Tasks-Qualified Service TechnicianGlass Cleaning Exterior and Interior of Installed Glass Gasket Seal and Glass Assembly InspectionIPI Pilot Flame Patterns Burner Ignition and OperationTypical Appliance System Getting StartedAny such action may cause a fire hazard Design and Installation ConsiderationsTools and Supplies Needed Inspect Appliance and ComponentsTRUE-42 Framing and ClearancesSelecting Appliance Location TRUE-36Constructing the Appliance Chase Minimum Framing DimensionsClearances Non-Combustible Mantel Legs or Wall Projections Mantel and Wall ProjectionsNon-Combustible Zone Combustible Mantel Legs or Wall ProjectionsTRUE-50 21 MINCombustible Mantel Projections NON-COMBUSTIBLE MaterialModel Hearth ExtensionVent Termination Minimum Clearances Termination LocationsCovered Alcove Applications Ft. Canada ..........not to be installed above a gas meterVent Information and Diagrams V1 Minimum Maximum Top Vent Horizontal Termination One ElbowTRUE-36 NG/LP, TRUE-42 NG TRUE-50 NG/LPMinimum Two Elbows+ H TRUE-36 NG/LP, TRUE-42 NG/LPTRUE-36 NG/LP, TRUE-42 NG/LP, TRUE-50 NG/LP Top Vent Horizontal Termination Three ElbowsFlue Restrictor Elbows Top Vent Vertical TerminationTRUE-36 NG/LP, TRUE-42 NG/LP, TRUE-50 NG/LP Ht Max Top Vent Vertical Termination Three ElbowsPVI-SLP PVK-80 and PVI-SLP InformationNon-Combustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration FramingPipe DVP Install the Ceiling FirestopVaulted Ceiling Installation Install Attic Insulation ShieldInstalling the Optional Heat-ZoneGas Kit Flat Ceiling InstallationVent Preparation Appliance PreparationSide Nailing Tab in Shipping Position Securing and Leveling the ApplianceInstalling Non-Combustible Facing Material Installing Non-combustible Facing MaterialAssemble Pipe Sections Installing Vent Pipe DVP PipeAttach Vent to the Firebox Assembly Assemble Vent SectionsDisassemble Vent Sections Secure the Vent SectionsAssemble and Install Storm Collar Install Metal Roof FlashingInstall Horizontal Termination Cap Install Vertical Termination CapHeat Shield Requirements for Horizontal Termination Gas Connection Gas InformationFuel Conversion Gas PressureElectrical Information Wiring RequirementsIntelliFire PlusTM Ignition System Wiring Optional Accessories RequirementsAccess Through Left Column Access Through Firebox Electrical Service and Repair Junction Box InstallationFinishing Template installation instructionFinishing Templates Finishing Templates Bends Inoperable Fixed Doors Splatter GuardFACTORY-SUPPLIED NON-COMBUSTIBLE Combustible or Board 10 Combustible Mantel Allowance TRUE-36, TRUE-42 MAX 21 MINFacing Material 14 Non-combustible Facing Diagram Operable Doors Dimension Inoperable Operable Door Doors ArchAppliance Setup LED’s Glowing Ember PlacementNotch for Install the Log Assembly Log Set Assembly LOGS-TRUE36Models TRUE-36C, TRUE-36H, TRUE-36S LOG Contacts Side Grate TineLOG Contacts Left Grate Tine TineLOG Contacts Grate Tine LOG #7 TRUE-42 only Back Tine LOG Contacts Refractory Notch Front TineNotch for For LOG #3 LOG Placement Slots NotchLOG #4 Flat AreaTOP of Burned Area Near LOG #1 LOG Resting in Notch LOG Contacts 8 Grate Tine Back Tine Front Tine LOG Contacts Refractory NotchTRUE-36 TRUE-42 TRUE-50 TOP Retaining Rail Notch Glass Frame Notch TRUE-50 Air Shutter SettingModel TRUE-36 TRUE-42Symptom Possible Cause Corrective Action TroubleshootingIntelliFire Plus Ignition System Troubleshooting Reference Materials Appliance Dimension DiagramLocation Inches Millimeters Appliance Dimensions TRUE-42 & TRUE-50 DVP-AS2 Vent Components DiagramsDVP-TRAP DVP-TRAP1 DVP-TRAP2 DVP-TRAPK1 DVP-TRAPK2Horizontal Termination Cap COOL-ADD RF6M RF12MBEK DVP-BEK2 DVP-TRAPFLSLP-LPC Optional Wire HarnessPower Vent Inline Description Part NumberDescription Comments Part Number Log Set AssemblyCService. ServicePartsParts At DepotStocked Service PartsDescription Comments Part Number Log Set Assembly TRUE-42S, TRUE-42H, TRUE-42C LOGS-TRUE50 TRUE-50S, TRUE-50H, TRUE-50C TRUE-36, TRUE-42, TRUE-50 #13 Valve AssemblyMYSTIC-EMBERS Contact Information