Hearth and Home Technologies TRUE-36, TRUE-42 LOG #4, LOG Placement Slots Notch, Flat Area

Page 58

Log Set Assembly: LOGS-TRUE50 LOG PLACEMENT INSTRUCTIONS

Models: TRUE-50C, TRUE-50H, TRUE-50S

LOG PLACEMENT TABS

Figure 1.

NOTCH FOR LOG #6

NOTCH FOR LOG #3

1

LOG PLACEMENT NOTCH

Figure 2.

CAUTION: Logs are fragile, handle with care. Log #1 (2282-701): Locate log placement notch on the bottom of log #1. See Figure 2. Mate outer notches on the bottom of Log #1 with the left and right grate tines. Slide Log #1 toward the rear of appliance until back side of Log #1 contacts the log placement tabs shown in Figure 1. See Figure 3.

1

Figure 3.

NOTCH FOR

2

3

LOG #4

BURNED AREA

2

LOG PLACEMENT SLOTS

NOTCH

Figure 4.

Log #2 (2282-702): Locate log placement notches on the bottom of Log #2. See Figure 4. Mate notches on the bottom of Log #2 as shown in Figure 5. Notch on front of log will contact right front grate tine and notch on right side of log will contact front inside corner of side grate tine.

NOTCH FOR

 

 

LOG #3

 

FLAT AREA

 

 

NOTCH FOR

1

FOR LOG #3

 

LOG #4

 

 

LOG CONTACTS

GRATE TINE

2

Figure 5.

58

Heat & Glo • TRUE-36, TRUE-42, TRUE-502282-900 Rev. D • 8/12

Image 58
Contents Do Discardnot ModelsWhat to do if you smell gas HOT SurfacesCongratulations Homeowner Reference InformationTable of Contents User GuideTroubleshooting Appliance SetupReference Materials Limited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsOperating Instructions User Guide Gas Fireplace SafetyYour Fireplace IPI Battery Tray/Battery Installation Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Clear SpaceControl Module Operation Module ResetNine Hour Safety Shutdown Feature Before Lighting FireplaceWhat to do if YOU Smell GAS Lighting Instructions IPIFinal inspection by GAS ValveIssue Solutions Frequently Asked QuestionsAfter Fireplace is Lit Maintenance and Service Gasket Seal and Glass Assembly Inspection Maintenance Tasks-Qualified Service TechnicianGlass Cleaning Exterior and Interior of Installed Glass D ReplacementBurner Ignition and Operation IPI Pilot Flame PatternsGetting Started Typical Appliance SystemInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Any such action may cause a fire hazardTRUE-36 Framing and ClearancesSelecting Appliance Location TRUE-42Constructing the Appliance Chase Minimum Framing DimensionsClearances Combustible Mantel Legs or Wall Projections Mantel and Wall ProjectionsNon-Combustible Zone Non-Combustible Mantel Legs or Wall ProjectionsNON-COMBUSTIBLE Material 21 MINCombustible Mantel Projections TRUE-50Hearth Extension ModelTermination Locations Vent Termination Minimum ClearancesFt. Canada ..........not to be installed above a gas meter Covered Alcove ApplicationsVent Information and Diagrams TRUE-50 NG/LP Top Vent Horizontal Termination One ElbowTRUE-36 NG/LP, TRUE-42 NG V1 Minimum MaximumTRUE-36 NG/LP, TRUE-42 NG/LP Two Elbows+ H MinimumTop Vent Horizontal Termination Three Elbows TRUE-36 NG/LP, TRUE-42 NG/LP, TRUE-50 NG/LPFlue Restrictor Top Vent Vertical Termination ElbowsTop Vent Vertical Termination Three Elbows TRUE-36 NG/LP, TRUE-42 NG/LP, TRUE-50 NG/LP Ht MaxPVK-80 and PVI-SLP Information PVI-SLPWall Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Non-Combustible Wall PenetrationInstall the Ceiling Firestop Pipe DVPFlat Ceiling Installation Install Attic Insulation ShieldInstalling the Optional Heat-ZoneGas Kit Vaulted Ceiling InstallationAppliance Preparation Vent PreparationSecuring and Leveling the Appliance Side Nailing Tab in Shipping PositionInstalling Non-combustible Facing Material Installing Non-Combustible Facing MaterialAssemble Vent Sections Installing Vent Pipe DVP PipeAttach Vent to the Firebox Assembly Assemble Pipe SectionsSecure the Vent Sections Disassemble Vent SectionsInstall Metal Roof Flashing Assemble and Install Storm CollarInstall Horizontal Termination Cap Install Vertical Termination CapHeat Shield Requirements for Horizontal Termination Gas Pressure Gas InformationFuel Conversion Gas ConnectionOptional Accessories Requirements Wiring RequirementsIntelliFire PlusTM Ignition System Wiring Electrical InformationElectrical Service and Repair Junction Box Installation Access Through Left Column Access Through FireboxFinishing Template installation instructionFinishing Templates Splatter Guard Finishing Templates Bends Inoperable Fixed DoorsFACTORY-SUPPLIED NON-COMBUSTIBLE Combustible or Board MAX 21 MIN 10 Combustible Mantel Allowance TRUE-36, TRUE-4214 Non-combustible Facing Diagram Facing MaterialArch Dimension Inoperable Operable DoorDoors Operable DoorsAppliance Setup Glowing Ember Placement LED’sLOG Contacts Side Grate Tine Install the Log Assembly Log Set Assembly LOGS-TRUE36Models TRUE-36C, TRUE-36H, TRUE-36S Notch forTine LOG Contacts Left Grate TineBack Tine LOG Contacts Refractory Notch Front Tine LOG Contacts Grate Tine LOG #7 TRUE-42 onlyFlat Area LOG Placement Slots NotchLOG #4 Notch for For LOG #3TOP of Burned Area Near LOG #1 LOG Resting in Notch Back Tine Front Tine LOG Contacts Refractory Notch LOG Contacts 8 Grate TineTRUE-36 TRUE-42 TRUE-50 TOP Retaining Rail Notch Glass Frame Notch TRUE-42 Air Shutter SettingModel TRUE-36 TRUE-50Symptom Possible Cause Corrective Action TroubleshootingIntelliFire Plus Ignition System Troubleshooting Reference Materials Appliance Dimension DiagramLocation Inches Millimeters Appliance Dimensions TRUE-42 & TRUE-50 Vent Components Diagrams DVP-AS2DVP-TRAP DVP-TRAP1 DVP-TRAP2 DVP-TRAPK1 DVP-TRAPK2Horizontal Termination Cap DVP-TRAPFL RF6M RF12MBEK DVP-BEK2 COOL-ADDDescription Part Number Optional Wire HarnessPower Vent Inline SLP-LPCAt Depot Log Set AssemblyCService. ServicePartsParts Description Comments Part NumberStocked Service PartsDescription Comments Part Number Log Set Assembly TRUE-42S, TRUE-42H, TRUE-42C LOGS-TRUE50 TRUE-50S, TRUE-50H, TRUE-50C #13 Valve Assembly TRUE-36, TRUE-42, TRUE-50MYSTIC-EMBERS Contact Information

TRUE-36, TRUE-50, TRUE-42 specifications

Hearth and Home Technologies offers a range of innovative fireplaces, and the TRUE series stands out for its exceptional design and advanced technology. The TRUE-42, TRUE-50, and TRUE-36 models are popular choices among homeowners looking for contemporary aesthetics combined with efficient heating solutions.

The TRUE-42 fireplace is designed for modern living spaces, offering a clear view of the flames from multiple angles. Its sleek, linear design allows it to be seamlessly incorporated into any room. One of its main features is the expansive glass front that enhances the visuals of the fire while promoting maximum heat output. With an input range of 27,000 to 50,000 BTUs, this model excels at warming larger spaces efficiently. Additionally, it includes adjustable flame height and various log or ember bed options, allowing users to customize their fire experience.

The TRUE-50 model takes the design and performance up a notch, providing an even larger viewing area with its 50-inch glass front. This fireplace is perfect for grand living rooms or commercial spaces, where ambiance and style are a priority. It features innovative technology such as auto ignition and an optional remote control, giving homeowners the flexibility to control the fire with ease. The TRUE-50 also allows for venting options, making it adaptable to a range of installation requirements, thus enhancing its versatility in different home settings.

Lastly, the TRUE-36 serves as a more compact option without sacrificing aesthetic appeal. It delivers the same stunning flame effect and high-efficiency heating as its larger counterparts, making it suitable for smaller rooms or cozy spaces. The TRUE-36 is designed to create a focal point in any room, featuring modern controls and customizable flame options.

All TRUE fireplaces boast advanced technologies like the Intellifire ignition system, which enhances safety and convenience by ensuring reliable lighting every time. Energy efficiency is a priority as well, with these models meeting stringent environmental standards, thereby providing heat without excessive emissions.

In summary, Hearth and Home Technologies’ TRUE series, including the TRUE-42, TRUE-50, and TRUE-36, offers cutting-edge design and performance. These models exemplify modern fireplace innovation, blending style, efficiency, and technological advancement, making them an excellent choice for any home or commercial space looking to enhance its ambiance.