GTO SL-2000B, SL-1000B installation manual Potentiometers

Page 23

POTENTIOMETERS

The three (3) potentiometers on the control board operate like a volume control on a radio. They control the auto close timer, inertia, and obstruction sensitivity of the operator. Use a small slotted screwdriver to turn the arrow in the center of the potentiometer. Clockwise rotation increases the setting (MAX). Counterclockwise rotation decreases the setting (MIN).

PULL/PUSH

SNGL/DUAL

SEQ1

SEQ2

ON

1 2 3 4

AUTOCLOSE

60

OFF120

INERTIA

MINMAX

OBSTRUCT

SENS.

MINMAX

LEARN

AUTO CLOSE (auto close timer): Determines how long the gate will remain open before it automatically closes. The limits are OFF to 120 seconds. The factory setting is OFF.

INERTIA: Fine tunes obstruction sensitivity in the opening and closing modes. INERTIA allows the operator to attempt to push an obstruction clear of the gate path. When INERTIA is set to MIN the operator will obstruct quickly (i.e, will attempt to push an obstruction briefly); when set to MAX the operator will obstruct slowly (i.e., will push against an obstruct for a longer period). The factory setting is MIN.

OBSTRUCT SENS. (obstruction sensitivity): Determines the amount of force exerted by the gate on an obstruction before the operator stops and reverses. The gate will exert minimum force before obstructing when set to MIN. When

R

B

G

 

RCVR

set to MAX, the operator will exert maximum gate force before obstructing (i.e., the operator will require greater resistance before stopping and revers- ing.). The factory setting is MIN.

READ WARNING BELOW!

NOTE: Heavy gates and gates with high wind resistance may require the OB- STRUCT SENS. potentiometer to be set closer to MAX to prevent the opera- tor from obstructing. Keep in mind, however, that while you must determine the best setting for smooth gate operation, you must ALSO determine the low- est possible setting for safe gate operation.

ALWAYS KEEP SAFETY AT THE TOP OF YOUR LIST WHEN ADJUSTING OR SERVICING YOUR AUTOMATIC GATE OPERATOR!

WARNING!

All three potentiometers were set to minimum at the factory. The OBSTRUCT SENS. potentiometer MUST be adjusted above the factory setting for your GTO/PRO SL-1000 or SL-2000 operator to function properly. If the potentiometer is left at MIN, your gate operator may “obstruct” (i.e., stop and reverse) as soon as it is activated.

BE SURE TO PROPERLY RETEST THE GATE OPERATOR AFTER MAKING ANY ADJUSTMENTS; FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH.

21

Image 23
Contents Automatic Gate Operator Table of Contents Important Safety Instructions For the System Designer For the InstallerBefore Installation II. During InstallationIII. After Installation Secondary Means of Protection Against Entrapment Entrapment Alarm UL 325No ONE should Cross the Path of the Moving Gate For the CONSUMER/END UserPoint hazard Required Safety Precautions for GatesSL Series Moving Gate Can Cause Injury Or Death GTO PRO SL-1000 Series Technical Specifications GTO PRO SL-2000 Series Technical Specifications Parts Identification Gate Preparation Single Gate Operator InstallationOverview of Operator Installation Mounting the Legs on the Slide Gate Operator Recommended Wiring and USE of ConduitCentered between roller posts and aligned with string Determining the Mounting Position and Mounting the OperatorProceeding to the next step Before Pouring Concrete 1 Make sure operator isTo Open the Gate Manually Installing the ChainNo more than 1000 ft Powering the SystemConnecting the Battery Installation of the GTO TransformerEstimated Maximum Number of Cycles Per Day Solar Zones and Gate ActivityStep 18VAC See Illustration KRight Control Board SettingsPotentiometers Setting the Personal Transmitter Code Run the cable through PVC conduit to protect it from damage Mounting the ReceiverCounter Clockwise Adjusting the Limit SwitchesIf your gate opens from Right to Left However, if your gate opens from Left to RightConnecting Additional Safety Devices Connecting Safety DevicesORG Orange Used with GRN Green Connecting AccessoriesWHT White Used with GRN Green BLU Blue Used with GRN GreenAttaching the Housing Maintenance Maintenance Trouble Shooting GuideConnected to these terminals System Test SpecificationsWarranty and Repair Service Limited Two Year WarrantyInstructions for the Installation Dual Slide Gate System Second Gate Auxiliary Operator Parts & Hardware Dual Gate System InstallationControl Unit Preparing the GatesThis Step is for SL-2000/2200 Installation only Wiring the Second OperatorRefer to the illustrations on the next Setting the Control Board for Dual Gate InstallationsStep Accessories #41 Slide Gate Chain RB207 Vehicular Gate Operator Class Categories When You Know Multiply By To Find SymbolInstructions Installation Check ListInstallation of this operator conforms to Class