Genie directlift 2060 warranty Lubricant, As needed Replace lightbulbs

Page 13

2060-3060 eng.qxd 11/9/05 11:02 AM Page 13

IMPORTANT

SAFETY

INSTRUCTIONS

WARNING

TO REDUCE THE RISK OF SEVERE INJURY OR DEATH

1READ AND FOLLOW ALL INSTRUCTIONS.

2Never let children operate or play with the Door Controls. Keep the Remote Control away from children.

3Always keep the moving door in sight and away from people and objects until the door is completely closed. NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR.

4NEVER GO UNDER A STOPPED, PARTIALLY OPEN DOOR.

5Test Opener monthly. The door MUST reverse on contact with a 1-1/2" high object (or a 2" x 4" board laid flat) at the center of the doorway on the floor. After adjusting either the Force or the Limit of travel, retest the Door Opener. Failure to adjust the Opener properly may cause severe injury

or death.

6When possible use the Emergency Release only when the door is closed. Use caution when using this Release with the door open. Weak or broken springs are capable of increasing the rate of door closure and increasing the risk of severe injury or death.

7KEEP GARAGE DOORS PROPERLY BALANCED. See garage door Owner's Manual. An improperly balanced door increases the risk of severe injury or death. Have a Genie Factory Authorized Dealer make repairs to cables, spring assemblies, and other hardware.

8SAVE THESE INSTRUCTIONS.

WARNING

Use the Wall Console included with Opener. Any other wall console can cause the Opener to operate unexpectedly and the light to stop working.

MAINTENANCE

AMonthly:

Door springs and door hardware:

Oil door roller, bearings, and hinges using silicone lubricant or light oil.

WARNING

Do not operate door automatically or manually if springs are broken. Contact a Genie Factory Authorized Dealer for service or call Customer Service at 1-800-35-GENIE.

Balance Door.

Close door.

Release Carriage Assembly from Rail Assembly by pulling the Emergency Release Knob towards the door.

Raise door manually 3'- 4' and verify that door stays at that position. See Check Step 2 on page 5.

NOTE

When the door is 3' - 4' above the ground, the door should stay open. Slight movement is acceptable. If the door moves too much, contact a Genie Factory Authorized Dealer for service or call Customer Service at

1-800-35-GENIE.

Reattach Carriage Assembly to Rail Assembly:

a.Pull the Emergency Release Knob toward Power Head.

b.Close door.

Contact Reverse Test.

Perform Adjustment 2 on page 10.

WARNING

If the door fails to reverse on contact with the board, adjust the Close Force Control as specified in Set Limit Switches and Force Controls on page 10. If the Opener still fails, contact a Genie Factory Authorized Dealer for service or call Customer Service at 1-800-35-GENIE.

BYearly:

Wipe off old excess lubricant from Drive Screw.

Lubricate Drive Screw with Genie Lubricant (GLU-3)

NOTE

Use ONLY Genie Lubricant (GLU-3). Other lubricants may damage the Opener.

 

 

 

 

 

 

 

 

 

e

 

 

 

 

 

 

 

 

 

g

t

GLU-3

 

 

 

 

 

 

ra

 

D

 

 

 

iveGa

 

ican

 

PartN

 

 

 

 

 

 

ew

 

 

erLubr

 

 

cr

Dr

 

 

 

 

 

 

 

 

en

-3

 

 

 

 

S

 

 

p

 

 

 

 

 

 

rO

 

o.GLU

 

 

 

 

oo

 

 

 

 

 

 

Lubricant

FCC AND IC CERTIFIED

All devices comply with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, includ- ing interference that may cause undesired operation.

CAs needed

• Replace lightbulbs.

For Help, call 1-800-35-GENIE or visit www.geniecompany.com

13

Image 13
Contents 2060 3060 Savethese Instructions Your Garage Door Opener Documentation Package Operation and Maintenance ManualSafety Features Important Installation InstructionsThickness Check Check Garage DoorALIGNMENT, Operation Balance Check Check Door Header Area Power Source Check Check Power HeadMounting Area Perforated Angle Iron Conduit WoodE G Check Check SAFE-T-BEAMMounting Bracket Location Maintenance and Adjustments 4 board laid flat Setting Contact Reverse FunctionRemote Controls AccessoriesProgramming 1 Programming Pop off the back of the transmitterInstall Lightbulbs Install Light Bulbs and LensAs needed Replace lightbulbs LubricantCheck wiring Safe-T-Beam System Self-Diagnostic TroubleshootingPower has been interrupted Remove power and reapply Wiring to Source missing or badGeneral Troubleshooting Opening Cover May Cause Electric Shock Wiring DiagramParts Identification Power Head AssemblyParts List cont’ Ordering Instructions 2060-3060 eng.qxd 11/9/05 1102 AM Índice Avec Télécommande Intellicode ETTable DES Matières 3559935907Genie Company Garantía Limitada Manual de funcionamiento y mantenimiento Características DE Seguridad Perspectiva DE Peligros PotencialesCinta métrica de más de 12 Lápiz Escalera Nivel Lista DE Verificacion DE PreinstalacionRuban à mesurer de 3,6 m Crayon Echelle Niveau Verificación del Paso 4 Verifque EL Área DEL Verificación del Paso 3 Mida LA Altura DE LAContrôle Étape Bandes perforées Figura 5 Verifique el lugar de la caja de controlFigura 8 Herramientas recomendadas Contrôle Étape 8 Outils RecommandesJustes Maintenance ET RéglagesFijando el interruptor limitador de cerrar Figura Oprima la consola de pared para cerrar la puerta del garajeCierre la puerta usando la consola de pared Abra la puerta del garaje usando la consola de paredAccesorios AccessoiresSe recomienda las bombillas reforzadas de 130 voltios Les télécommandes sont programmées individuellementInstrucciones DE Seguridad Importantes Maintenance PériodiqueImportantes Consignes DE Sécurité Equilibre la puerta Cierre la puertaFonctionnement normal Aucune Operación normal No requiere ningunaInvestigación de averías generales Résolutions des problèmes Schéma DE Câblage Diagrama DE ConexionesDe la tête motorisée Caja de controlConjunto del riel Lista de piezasListe des pièces Rail