Genie directlift 2060 warranty Maintenance and Adjustments

Page 9

2060-3060 eng.qxd 11/9/05 11:02 AM Page 9

MAINTENANCE AND ADJUSTMENTS

Adjustment 1: CH SET LIMIT SWITCHES AND FORCE CONTROLS

Rough Setting of Limit Switches

ASetting Close Limit Switch (Figure 9):

Check that Carriage Assembly is disengaged.

With garage door fully closed, slide Close Limit Switch toward Carriage until white lever is fully lifted.

Tighten Set Screw. Do Not over-tighten.

BSetting Open Limit Switch:

Manually open garage door to full open position.

Slide Open Limit Switch toward Carriage until white lever is fully lifted.

Tighten Set Screw. Do not over-tighten.

Re-engage Carriage Assembly.

Setting Force Controls and Final Adjustment of Limit Switches

WARNING

The garage door opens rapidly, and can cause serious injury or death.

Keep the path clear.

Position the ladder to the side of the Power Head so it is clear of all moving parts of the Opener and the door.

Set the door Opener to use the minimum force needed to open the door.

ACLOSE ADJUSTMENT

On front panel of Power Head find adjusting screw marked “CLOSE” (Figure 9).

Gently turn screw counterclockwise until it stops.

Very little force is required to turn adjusting screw.

Press Wall Console to close garage door.

Observe if door stops at “CLOSE” limit switch. If door is fully closed—adjustment is finished. Go to “OPEN” Adjustment.

If door stops but is not fully closed,

a.Measure distance between bottom of door and floor.

b.Move “CLOSE” Limit Switch that same distance toward door.

If door stops and/or reverses before reaching the “CLOSE” Limit Switch

a.Slightly increase CLOSE Force setting (clockwise).

If door reverses after contacting floor, move Limit Switch toward Power Head.

If door fails to move, check Safe-T-Beam® System. See Troubleshooting Section, page 14.

Tighten Limit Switch Set Screw. Do not over-tighten (strip) Limit Switch Set Screw.

Open adjustment next page.

NOTE

Little effort is required to turn the Force Adjusting Knobs.

If the door stops moving while opening or closing, adjust the Open Force or Close Force Controls slightly clockwise (to slightly increase the force) and retry the step.

The Open Force and Close Force Controls are to be set to the minimum force necessary to ensure the door smoothly opens and

closes completely.

Ensure the Carriage Assembly is engaged and is between the two Limit Switches before operating the Opener.

FORCE

CONTROLS

CLOSE

OPEN

CLOSE

OPEN

Figure 9 Making Force Adjustments

For Help, call 1-800-35-GENIE or visit www.geniecompany.com

9

Image 9
Contents 2060 3060 Savethese Instructions Your Garage Door Opener Documentation Package Operation and Maintenance ManualSafety Features Important Installation InstructionsCheck Check Garage Door ThicknessALIGNMENT, Operation Balance Check Check Door Header Area Power Source Check Check Power HeadMounting Area Perforated Angle Iron Conduit WoodCheck Check SAFE-T-BEAM E GMounting Bracket Location Maintenance and Adjustments 4 board laid flat Setting Contact Reverse FunctionRemote Controls AccessoriesProgramming 1 Programming Pop off the back of the transmitterInstall Lightbulbs Install Light Bulbs and LensAs needed Replace lightbulbs LubricantCheck wiring Safe-T-Beam System Self-Diagnostic TroubleshootingPower has been interrupted Remove power and reapply Wiring to Source missing or badGeneral Troubleshooting Opening Cover May Cause Electric Shock Wiring DiagramParts Identification Power Head AssemblyParts List cont’ Ordering Instructions 2060-3060 eng.qxd 11/9/05 1102 AM Índice Avec Télécommande Intellicode ETTable DES Matières 3559935907Genie Company Garantía Limitada Manual de funcionamiento y mantenimiento Características DE Seguridad Perspectiva DE Peligros PotencialesLista DE Verificacion DE Preinstalacion Cinta métrica de más de 12 Lápiz Escalera NivelRuban à mesurer de 3,6 m Crayon Echelle Niveau Verificación del Paso 3 Mida LA Altura DE LA Verificación del Paso 4 Verifque EL Área DELContrôle Étape Bandes perforées Figura 5 Verifique el lugar de la caja de controlFigura 8 Herramientas recomendadas Contrôle Étape 8 Outils RecommandesJustes Maintenance ET RéglagesFijando el interruptor limitador de cerrar Figura Oprima la consola de pared para cerrar la puerta del garajeCierre la puerta usando la consola de pared Abra la puerta del garaje usando la consola de paredAccesorios AccessoiresSe recomienda las bombillas reforzadas de 130 voltios Les télécommandes sont programmées individuellementInstrucciones DE Seguridad Importantes Maintenance PériodiqueImportantes Consignes DE Sécurité Equilibre la puerta Cierre la puertaFonctionnement normal Aucune Operación normal No requiere ningunaInvestigación de averías generales Résolutions des problèmes Schéma DE Câblage Diagrama DE ConexionesDe la tête motorisée Caja de controlConjunto del riel Lista de piezasListe des pièces Rail