Genie directlift 2060 Check Check Power Head, Mounting Area, Power Source, Perforated Straps

Page 7

2060-3060 eng.qxd 11/9/05 11:02 AM Page 7

Check Step 5: CHECK POWER HEAD

MOUNTING AREA

Check ceiling or space above where Opener Power Head will be mounted (Figure 5):

AMeasure from garage door center line mark toward rear of garage:

Approximately 10' back if garage has a 7' 6" door.

Approximately 11' back if garage has an 8' 0" door.

NOTE

Since garage construction varies widely, there may be hardware required in addition to the mounting straps.

Check for 15 Amp, 120 Volt grounded outlet or wiring box within 3 feet of

Power Head.

10'

for 7-1/2' doors

11' for 8' doors

Figure 5 Check Power Head location

BFind location of ceiling joist or truss above where Opener Power Head will be and estimate type and quantity of materials needed for your installation (Figure 6).

MOUNTING EXAMPLES

 

 

 

Perforated Angle Iron

Conduit

Wood

Perforated Straps

FINISHED CEILINGS

Locate ceiling joists or trusses using a stud finder or similar device.

Attach angle iron (not included) to joists or trusses through finish material using Lag Screws.

OPEN CEILINGS

Straps and angle iron may attach directly to joists or trusses.

Figure 6 Mounting methods for open beam or finished ceilings

Check Step 6: CHECK CEILING FOR GROUNDED

POWER SOURCE

ACheck that there is a 15 Amp 120 Volt grounded electrical outlet or grounded permanent wiring box (per building code) within 3' of Opener Power Head:

If not, an outlet or wiring box must be installed. Contact a licensed electrician for installation.

If building codes require permanent wiring, Power Head must be partially disassembled to install appropriate wiring in place of Power Cord (See Installation Poster).

NOTE

Permanent wiring must be installed by a Licensed

Electrician. Not all Genie Factory Authorized Dealers are

Licensed Electrician's. Contact someone who is a Licensed

Electrician.

For Help, call 1-800-35-GENIE or visit www.geniecompany.com

7

Image 7
Contents 2060 3060 Savethese Instructions Your Garage Door Opener Documentation Package Operation and Maintenance ManualSafety Features Important Installation InstructionsThickness Check Check Garage DoorALIGNMENT, Operation Balance Check Check Door Header Area Perforated Angle Iron Conduit Wood Check Check Power HeadPower Source Mounting AreaE G Check Check SAFE-T-BEAMMounting Bracket Location Maintenance and Adjustments 4 board laid flat Setting Contact Reverse FunctionPop off the back of the transmitter AccessoriesRemote Controls Programming 1 ProgrammingInstall Lightbulbs Install Light Bulbs and LensAs needed Replace lightbulbs LubricantWiring to Source missing or bad Safe-T-Beam System Self-Diagnostic TroubleshootingCheck wiring Power has been interrupted Remove power and reapplyGeneral Troubleshooting Opening Cover May Cause Electric Shock Wiring DiagramParts Identification Power Head AssemblyParts List cont’ Ordering Instructions 2060-3060 eng.qxd 11/9/05 1102 AM 3559935907 Avec Télécommande Intellicode ETÍndice Table DES MatièresGenie Company Garantía Limitada Manual de funcionamiento y mantenimiento Características DE Seguridad Perspectiva DE Peligros PotencialesCinta métrica de más de 12 Lápiz Escalera Nivel Lista DE Verificacion DE PreinstalacionRuban à mesurer de 3,6 m Crayon Echelle Niveau Verificación del Paso 4 Verifque EL Área DEL Verificación del Paso 3 Mida LA Altura DE LAContrôle Étape Bandes perforées Figura 5 Verifique el lugar de la caja de controlFigura 8 Herramientas recomendadas Contrôle Étape 8 Outils RecommandesOprima la consola de pared para cerrar la puerta del garaje Maintenance ET RéglagesJustes Fijando el interruptor limitador de cerrar FiguraCierre la puerta usando la consola de pared Abra la puerta del garaje usando la consola de paredAccesorios AccessoiresSe recomienda las bombillas reforzadas de 130 voltios Les télécommandes sont programmées individuellementEquilibre la puerta Cierre la puerta Maintenance PériodiqueInstrucciones DE Seguridad Importantes Importantes Consignes DE SécuritéFonctionnement normal Aucune Operación normal No requiere ningunaInvestigación de averías generales Résolutions des problèmes Schéma DE Câblage Diagrama DE ConexionesDe la tête motorisée Caja de controlConjunto del riel Lista de piezasListe des pièces Rail