Genie directlift 2060 warranty General Troubleshooting

Page 15

2060-3060 eng.qxd 11/9/05 11:02 AM Page 15

 

 

General Troubleshooting

Problem

 

What To Do

 

1. Check Lock switch on Wall Control (see Wall Console section on Installation Poster).

Opener does not run

from Wall Control

2. Check Power Source:

 

 

For Grounded Plug Connection.

 

 

– Plug a lamp into the electrical outlet used for the door opener.

 

 

a. If lamp lights, power source is good.

 

 

b. If lamp does not light, check fuse or circuit breaker.

 

 

For Permanent Wiring Connection.

 

 

– Check fuse or circuit breaker.

 

3. Check connections (see Wall Console section on Installation Poster):

 

At Power Head Terminals and Wall Control.

Door Opener starts

1. Check Wires to ensure that they are not cut (Stapes can cut insulation and short Wires)

for no apparent reason

 

Replace any shorting Staples and shorted Wires.

 

2. Was Remote Control lost or stolen? If so, erase all Remote Control codes from Receiver’s memory

 

 

and reprogram for remaining remote controls. (See Erase All Receiver Memory on page 11).

 

3. Ensure that no Buttons are stuck “pushed-in” on Wall Console or any Remote Controls.

Door starts down, then

1.

Check Close Limit Switch setting (page 9 and Installation Poster). Adjust as needed.

stops before it is

2.

Check Force Setting (page 9). Adjust as needed.

completely closed

3.

Check for shorted wires.

 

 

 

Door starts down, then

1.

If a new installation, check Door Arm position.

stops and goes back up

2.

Check operation of Contact Reverse function.

 

3. Check Safe-T-Beam® System for beam obstruction or misalignment of Lenses.

 

4. Check Safe-T-Beam® System diagnostic code.

 

5. Check Close Force adjustment (see Set Limit Switches and Force Controls on page 9). Adjust as needed.

 

6. Check garage door for binding.

Door will only run closed

1.

Check Open Limit Switch for a short circuit and for proper wiring.

 

2.

Check Open Force adjustment (see Set Limit Switches and Force Controls on page 9). Adjust as needed.

 

3. Check condition of garage door and door spring(s).

 

4. WARNING: If you suspect a problem with the garage door hardware or springs,contact a Genie

 

 

Factory Authorized Dealer for service,or contact Customer Service at 1-800-35-GENIE.

 

5. Check position of Lock Switch on Console.

Door will only run open

1.

Check Safe-T-Beam® System as detailed in the Safe-T-Beam® System Self-diagnostic Troubleshooting Chart

 

 

(page 14).

 

2. Check Close Limit Switch for a short circuit and for proper wiring.

 

3. Check Close Force adjustment (see Set Limit Switches and Force Controls on page 9). Adjust as needed.

 

 

 

Lights will not turn off

1.

Disconnect Wires connecting Wall Console to Power Head (see“Wall Console Installation”-on Installationposter).

 

 

Check their condition and either replace or reconnect.

 

2. Until a replacement Wall Console can be obtained,disconnect Wall Console and use only Remote Controls

 

 

or Wireless Keypad to operate Opener.

 

3. Check for non-compatible wall control.

Door starts up, but stops

1. Check (ensure) that garage door and Opener are in good repair, properly lubricated, and properly

before it is

 

balanced as detailed in Maintenance Section.

completely open

2. WARNING: If you suspect a problem with the garage door hardware or springs,contact a Genie Factory

 

 

Authorized Dealer for service,or contact Customer Service at 1-800-35-GENIE.

 

3. Check Open Limit Switch for a short circuit and for proper wiring.

 

4. Check Open Force adjustment (see Set Limit Switches and Force Controls on page 9). Adjust as needed.

 

 

 

Operator runs,but door

1.

Ensure Carriage Assembly is engaged to Rail Drive Screw (see Install Carriage Assembly -INSTALLATION POSTER).

does not move

2. Check Force adjustment (see Set Limit Switches and Force Controls on page 9). Adjust as needed.

 

3. Check that all sections of Rail Drive Screw are turning when Motor runs. If not:

 

 

• Check condition (not cracked,split,or broken) and placement of Coupler. Replace as needed.

 

 

• Check condition (not cracked,split,or broken) and placement of Collar and Clip. Replace them

 

 

as needed.

Wall Console Vacation

1.

Ensure Carriage Assembly is in contact with Close Limit Switch.

Lock function does

2.

Check when door is fully closed,that Carriage activates Close Limit Switch. If not,adjust position of Close

not work

 

Limit Switch (See page 9).

 

 

 

Noisy Operation

1.

Be sure all fasteners are tight.

 

2. Check (ensure) that garage door and Opener are in good repair, properly lubricated, and properly

 

 

balanced as described in Maintenance Section (page 13).

 

 

 

For Help, call 1-800-35-GENIE or visit www.geniecompany.com

15

Image 15
Contents 2060 3060 Savethese Instructions Your Garage Door Opener Documentation Package Operation and Maintenance ManualSafety Features Important Installation InstructionsCheck Check Garage Door ThicknessALIGNMENT, Operation Balance Check Check Door Header Area Perforated Angle Iron Conduit Wood Check Check Power HeadPower Source Mounting AreaCheck Check SAFE-T-BEAM E GMounting Bracket Location Maintenance and Adjustments 4 board laid flat Setting Contact Reverse FunctionPop off the back of the transmitter AccessoriesRemote Controls Programming 1 ProgrammingInstall Lightbulbs Install Light Bulbs and LensAs needed Replace lightbulbs LubricantWiring to Source missing or bad Safe-T-Beam System Self-Diagnostic TroubleshootingCheck wiring Power has been interrupted Remove power and reapplyGeneral Troubleshooting Opening Cover May Cause Electric Shock Wiring DiagramParts Identification Power Head AssemblyParts List cont’ Ordering Instructions 2060-3060 eng.qxd 11/9/05 1102 AM 3559935907 Avec Télécommande Intellicode ETÍndice Table DES MatièresGenie Company Garantía Limitada Manual de funcionamiento y mantenimiento Características DE Seguridad Perspectiva DE Peligros PotencialesLista DE Verificacion DE Preinstalacion Cinta métrica de más de 12 Lápiz Escalera NivelRuban à mesurer de 3,6 m Crayon Echelle Niveau Verificación del Paso 3 Mida LA Altura DE LA Verificación del Paso 4 Verifque EL Área DELContrôle Étape Bandes perforées Figura 5 Verifique el lugar de la caja de controlFigura 8 Herramientas recomendadas Contrôle Étape 8 Outils RecommandesOprima la consola de pared para cerrar la puerta del garaje Maintenance ET RéglagesJustes Fijando el interruptor limitador de cerrar FiguraCierre la puerta usando la consola de pared Abra la puerta del garaje usando la consola de paredAccesorios AccessoiresSe recomienda las bombillas reforzadas de 130 voltios Les télécommandes sont programmées individuellementEquilibre la puerta Cierre la puerta Maintenance PériodiqueInstrucciones DE Seguridad Importantes Importantes Consignes DE SécuritéFonctionnement normal Aucune Operación normal No requiere ningunaInvestigación de averías generales Résolutions des problèmes Schéma DE Câblage Diagrama DE ConexionesDe la tête motorisée Caja de controlConjunto del riel Lista de piezasListe des pièces Rail