| General Troubleshooting |
Problem |
| What To Do |
| 1. Check Lock switch on Wall Control (see Wall Console section on Installation Poster). | |
Opener does not run | ||
from Wall Control | 2. Check Power Source: | |
|
| • For Grounded Plug Connection. |
|
| – Plug a lamp into the electrical outlet used for the door opener. |
|
| a. If lamp lights, power source is good. |
|
| b. If lamp does not light, check fuse or circuit breaker. |
|
| • For Permanent Wiring Connection. |
|
| – Check fuse or circuit breaker. |
| 3. Check connections (see Wall Console section on Installation Poster): | |
| • At Power Head Terminals and Wall Control. | |
Door Opener starts | 1. Check Wires to ensure that they are not cut (Stapes can cut insulation and short Wires) | |
for no apparent reason |
| Replace any shorting Staples and shorted Wires. |
| 2. Was Remote Control lost or stolen? If so, erase all Remote Control codes from Receiver’s memory | |
|
| and reprogram for remaining remote controls. (See Erase All Receiver Memory on page 11). |
| 3. Ensure that no Buttons are stuck | |
Door starts down, then | 1. | Check Close Limit Switch setting (page 9 and Installation Poster). Adjust as needed. |
stops before it is | 2. | Check Force Setting (page 9). Adjust as needed. |
completely closed | 3. | Check for shorted wires. |
|
|
|
Door starts down, then | 1. | If a new installation, check Door Arm position. |
stops and goes back up | 2. | Check operation of Contact Reverse function. |
| 3. Check | |
| 4. Check | |
| 5. Check Close Force adjustment (see Set Limit Switches and Force Controls on page 9). Adjust as needed. | |
| 6. Check garage door for binding. | |
Door will only run closed | 1. | Check Open Limit Switch for a short circuit and for proper wiring. |
| 2. | Check Open Force adjustment (see Set Limit Switches and Force Controls on page 9). Adjust as needed. |
| 3. Check condition of garage door and door spring(s). | |
| 4. WARNING: If you suspect a problem with the garage door hardware or springs,contact a Genie | |
|
| Factory Authorized Dealer for service,or contact Customer Service at |
| 5. Check position of Lock Switch on Console. | |
Door will only run open | 1. | Check |
|
| (page 14). |
| 2. Check Close Limit Switch for a short circuit and for proper wiring. | |
| 3. Check Close Force adjustment (see Set Limit Switches and Force Controls on page 9). Adjust as needed. | |
|
|
|
Lights will not turn off | 1. | Disconnect Wires connecting Wall Console to Power Head (see“Wall Console |
|
| Check their condition and either replace or reconnect. |
| 2. Until a replacement Wall Console can be obtained,disconnect Wall Console and use only Remote Controls | |
|
| or Wireless Keypad to operate Opener. |
| 3. Check for | |
Door starts up, but stops | 1. Check (ensure) that garage door and Opener are in good repair, properly lubricated, and properly | |
before it is |
| balanced as detailed in Maintenance Section. |
completely open | 2. WARNING: If you suspect a problem with the garage door hardware or springs,contact a Genie Factory | |
|
| Authorized Dealer for service,or contact Customer Service at |
| 3. Check Open Limit Switch for a short circuit and for proper wiring. | |
| 4. Check Open Force adjustment (see Set Limit Switches and Force Controls on page 9). Adjust as needed. | |
|
|
|
Operator runs,but door | 1. | Ensure Carriage Assembly is engaged to Rail Drive Screw (see Install Carriage Assembly |
does not move | 2. Check Force adjustment (see Set Limit Switches and Force Controls on page 9). Adjust as needed. | |
| 3. Check that all sections of Rail Drive Screw are turning when Motor runs. If not: | |
|
| • Check condition (not cracked,split,or broken) and placement of Coupler. Replace as needed. |
|
| • Check condition (not cracked,split,or broken) and placement of Collar and Clip. Replace them |
|
| as needed. |
Wall Console Vacation | 1. | Ensure Carriage Assembly is in contact with Close Limit Switch. |
Lock function does | 2. | Check when door is fully closed,that Carriage activates Close Limit Switch. If not,adjust position of Close |
not work |
| Limit Switch (See page 9). |
|
|
|
Noisy Operation | 1. | Be sure all fasteners are tight. |
| 2. Check (ensure) that garage door and Opener are in good repair, properly lubricated, and properly | |
|
| balanced as described in Maintenance Section (page 13). |
|
|
|
For Help, call | 15 |