Genie directlift 2060 warranty Safe-T-Beam System Self-Diagnostic Troubleshooting, Check wiring

Page 14

2060-3060 eng.qxd 11/9/05 11:02 AM Page 14

TROUBLESHOOTING

Safe-T-Beam® System Self-Diagnostic Troubleshooting

Source (Red LED)

Sensor (Green LED)

Possible Problem

Solution

ON

ON

Normal operation

None required

OFF

OFF

• Power Head not powered

• Check breakers, fuses, plugs

• Wiring from Power Head bad

• Check wiring for obvious shorts

 

 

 

 

 

 

OFF

ON

• Wiring to Source missing or bad

• Check wiring

• Power has been interrupted

• Remove power and reapply

 

 

2 BLINKS, Pause

 

• Beam not aligned

• Check Source, Sensor alignment

(Repeat)

ON

• Beam obstructed

• Check for obstruction

 

 

• Sensor defective

• Contact Customer Service

2 BLINKS, Pause

OFF

• Wire to Sensor missing or bad

• Check wiring

(Repeat)

• Sensor defective

• Contact Customer Service

 

 

 

 

 

3 BLINKS, Pause

ON

• Sensor receiving interference

• Determine source of interference

(Repeat)

 

• Check for interference from sun-

 

 

 

 

 

light or a source unit on an

 

 

 

adjacent door

 

 

 

• Contact Customer Service

4 BLINKS, Pause

ON

• Source not sending pulses

• Contact Customer Service

(Repeat)

• Source defective

• Contact Customer Service

 

 

 

 

 

14

For Help, call 1-800-35-GENIE or visit www.geniecompany.com

Image 14 Contents
2060 3060 Savethese Instructions Operation and Maintenance Manual Your Garage Door Opener Documentation PackageImportant Installation Instructions Safety FeaturesALIGNMENT, Operation Balance Check Check Garage DoorThickness Check Check Door Header Area Mounting Area Check Check Power HeadPower Source Perforated Angle Iron Conduit WoodMounting Bracket Location Check Check SAFE-T-BEAME G Maintenance and Adjustments Setting Contact Reverse Function 4 board laid flatProgramming 1 Programming AccessoriesRemote Controls Pop off the back of the transmitterInstall Light Bulbs and Lens Install LightbulbsLubricant As needed Replace lightbulbsPower has been interrupted Remove power and reapply Safe-T-Beam System Self-Diagnostic TroubleshootingCheck wiring Wiring to Source missing or badGeneral Troubleshooting Wiring Diagram Opening Cover May Cause Electric ShockPower Head Assembly Parts IdentificationParts List cont’ Ordering Instructions 2060-3060 eng.qxd 11/9/05 1102 AM Table DES Matières Avec Télécommande Intellicode ETÍndice 3559935907Genie Company Garantía Limitada Manual de funcionamiento y mantenimiento Perspectiva DE Peligros Potenciales Características DE SeguridadRuban à mesurer de 3,6 m Crayon Echelle Niveau Lista DE Verificacion DE PreinstalacionCinta métrica de más de 12 Lápiz Escalera Nivel Contrôle Étape Verificación del Paso 3 Mida LA Altura DE LAVerificación del Paso 4 Verifque EL Área DEL Figura 5 Verifique el lugar de la caja de control Bandes perforéesContrôle Étape 8 Outils Recommandes Figura 8 Herramientas recomendadasFijando el interruptor limitador de cerrar Figura Maintenance ET RéglagesJustes Oprima la consola de pared para cerrar la puerta del garajeAbra la puerta del garaje usando la consola de pared Cierre la puerta usando la consola de paredAccessoires AccesoriosLes télécommandes sont programmées individuellement Se recomienda las bombillas reforzadas de 130 voltiosImportantes Consignes DE Sécurité Maintenance PériodiqueInstrucciones DE Seguridad Importantes Equilibre la puerta Cierre la puertaOperación normal No requiere ninguna Fonctionnement normal AucuneInvestigación de averías generales Résolutions des problèmes Diagrama DE Conexiones Schéma DE CâblageCaja de control De la tête motoriséeLista de piezas Conjunto del rielRail Liste des pièces