PRE-INSTALLATION CHECKLIST

This Opener includes parts and supplies needed to install in most garages and connect to most garage doors. There are many variations of garages and garage doors. A few additional parts and supplies may be needed to install Opener into your garage and connect to your garage door. While checking items listed below, note any additional items you will need.

Tools used in this section:

12'+ Tape Measure Pencil Ladder Level

Check following items before assembling Opener:

Check Step 1: CHECK DOOR CONDITION AND

THICKNESS

Check condition of vertical stile in center of door (Figure 2), and its connection to door’s top and bottom beams.

AIf door frame is nailed together and not a solid connection, door frame must be braced or reinforced before installing Opener.

BIf door is “lightweight” (made with frame and skin - not solid), door (including door frame) must be braced or reinforced before installing Opener.

CA door opener reinforcement bracket may also be needed to connect garage door to Opener's Door Bracket. This Opener is designed for installation on a properly braced sectional door or solidly braced one-piece door.

DContact your Genie Factory Authorized Dealer or dealer of your garage door for any necessary bracing and a door opener reinforcement bracket (if needed) before proceeding.

EIf you have a wooden door, measure door’s thickness. (1/4" x 2") Lag Screws are included for installing Door Bracket onto door. If your door is less than 2” thick, brace door or use shorter Door Bracket Lag Screws (1/4" x 1-1/4" – not included)

Check Step 2: CHECK GARAGE DOOR

ALIGNMENT, OPERATION,

AND BALANCE

ARaise door, check alignment and see if it moves freely (Figure 1). If door appears out of alignment, binds, or does not move smoothly, contact a Genie Factory Authorized Dealer or dealer of your garage door for repairs and adjustments to door mechanism.

WARNING:

If your door sticks, binds, or is out of balance, have it adjusted by a Genie Factory Authorized Dealer. Door springs, cables, pulleys, brackets and associated hardware are under extreme tension and can cause serious injury or death.

KEEP FEET CLEAR OF DOOR

3' - 4'

Sectional Door

3' - 4'

One-Piece Door Figure 1 Checking door balance

BRaise door to 3' – 4' above ground and carefully let go. Door should stay stationary. Slight movement is acceptable. More than slight movement means door is out of balance. Contact a Genie Factory Authorized

Dealer or dealer of

SECTIONAL DOOR, TORSION SPRINGS

SECTIONAL DOOR, EXTENSION SPRINGS

your garage door

for repairs and

 

Torsion

Extension

adjustments to door

Header

Springs

Springs

mechanism.

 

 

Area

 

Center

C Check door type.

 

 

 

 

 

Stile

Make a note of

 

 

 

 

 

whether it is a

 

 

 

sectional or a

 

 

Header

one-piece door

 

 

(Figure 2).

 

 

Area

 

 

 

Figure 2 Note Door Type

For Help, call 1-800-35-GENIE or visit www.geniecompany.com

ONE-PIECE DOOR, TRACKLESS

Header Area

Center Stile

5

Image 5
Contents 2060 3060 Savethese Instructions Your Garage Door Opener Documentation Package Operation and Maintenance ManualSafety Features Important Installation InstructionsALIGNMENT, Operation Balance Check Check Garage DoorThickness Check Check Door Header Area Power Source Check Check Power HeadMounting Area Perforated Angle Iron Conduit WoodMounting Bracket Location Check Check SAFE-T-BEAME G Maintenance and Adjustments 4 board laid flat Setting Contact Reverse FunctionRemote Controls AccessoriesProgramming 1 Programming Pop off the back of the transmitterInstall Lightbulbs Install Light Bulbs and LensAs needed Replace lightbulbs LubricantCheck wiring Safe-T-Beam System Self-Diagnostic TroubleshootingPower has been interrupted Remove power and reapply Wiring to Source missing or badGeneral Troubleshooting Opening Cover May Cause Electric Shock Wiring DiagramParts Identification Power Head AssemblyParts List cont’ Ordering Instructions 2060-3060 eng.qxd 11/9/05 1102 AM Índice Avec Télécommande Intellicode ETTable DES Matières 3559935907Genie Company Garantía Limitada Manual de funcionamiento y mantenimiento Características DE Seguridad Perspectiva DE Peligros PotencialesRuban à mesurer de 3,6 m Crayon Echelle Niveau Lista DE Verificacion DE PreinstalacionCinta métrica de más de 12 Lápiz Escalera Nivel Contrôle Étape Verificación del Paso 3 Mida LA Altura DE LAVerificación del Paso 4 Verifque EL Área DEL Bandes perforées Figura 5 Verifique el lugar de la caja de controlFigura 8 Herramientas recomendadas Contrôle Étape 8 Outils RecommandesJustes Maintenance ET RéglagesFijando el interruptor limitador de cerrar Figura Oprima la consola de pared para cerrar la puerta del garajeCierre la puerta usando la consola de pared Abra la puerta del garaje usando la consola de paredAccesorios AccessoiresSe recomienda las bombillas reforzadas de 130 voltios Les télécommandes sont programmées individuellementInstrucciones DE Seguridad Importantes Maintenance PériodiqueImportantes Consignes DE Sécurité Equilibre la puerta Cierre la puertaFonctionnement normal Aucune Operación normal No requiere ningunaInvestigación de averías generales Résolutions des problèmes Schéma DE Câblage Diagrama DE ConexionesDe la tête motorisée Caja de controlConjunto del riel Lista de piezasListe des pièces Rail