Genie directlift 2060 warranty Important Installation Instructions, Safety Features

Page 4

2060-3060 eng.qxd 11/9/05 11:02 AM Page 4

SAFETY INFORMATION

OVERVIEW OF POTENTIAL HAZARDS

Overhead doors are large,heavy objects that move with the help of springs under high tension and electric motors. Since moving objects,springs under tension,and electric motors can cause injuries, your safety and the safety of others depend on you reading the information in this manual. If you have questions or do not understand the information presented, call The Genie Company. or your local Genie Distributor.

In this section, and those that follow, the words Danger, Warning and Caution are used to emphasize important safety information. The word:

DANGER: indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.

WARNING: indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

CAUTION: indicates a potentially hazardous situation which, if not avoided, may result in injury or property damage. The word NOTE is used to indicate important steps to be followed or important considerations.

 

POTENTIAL HAZARD

EFFECT

PREVENTION

 

 

 

 

WARNING:

• Keep people clear of opening while door is moving.

 

 

 

 

 

 

 

 

 

 

 

 

Could result in death

Do Not allow children to play with the door operator.

 

MOVING DOOR

or serious injury.

Do Not operate a door that jams or one that has a broken spring.

 

 

 

 

 

 

 

WARNING:

• Turn off power before removing operator cover.

 

 

 

 

• When replacing cover, make sure wires are not pinched or near

 

 

 

 

Could result in death

 

 

 

 

moving parts.

 

 

 

 

or serious injury.

 

 

 

 

• Operator must be properly grounded.

 

ELECTRICAL SHOCK

 

 

 

 

 

 

 

 

 

Do Not try to remove, repair or adjust springs or anything to

 

 

 

 

WARNING:

which door spring parts are fastened, such as, wood blocks,

 

 

 

 

steel brackets, cables or other like items.

 

 

 

 

Could result in death

 

 

 

 

or serious injury.

• Repairs and adjustments must be made by a trained door

 

HIGH SPRING TENSION

 

system technician using proper tools and instructions.

IMPORTANT INSTALLATION

INSTRUCTIONS

WARNING:

TO REDUCE THE RISK OF SEVERE INJURY OR DEATH:

1READ AND FOLLOW ALL SAFETY, INSTALLATION AND OPERATION INSTRUCTIONS. If you have any questions or do not understand an instruction, call your authorized Genie installation professional.

2Do Not install operator on an improperly balanced door. An improperly balanced door could cause severe injury. Repairs and adjustments to cables, spring assembly, and other hardware must be made by a trained service person using proper tools and instructions.

3Remove all ropes, and disable all locks connected to the door before installing operator.

4Install door operator 7 feet or more above the floor. Mount the emergency release knob 6 feet above the floor.

5Do Not connect the operator to the source of power until instructed to do so.

6Locate the control button:

Within sight of door.

At a minimum height of 5 feet, so small children cannot reach it.

Away from all moving parts of the door.

7Install the entrapment WARNING label next to the wall button or console. Install the emergency release tag on, or next to, the emergency release

8The operator must reverse when the door contacts a 1-1/2 inch high object on the floor at the center of the doorway. This is about the size of a 2" x 4" board laid flat.

SAFETY FEATURES

Safe-T-Beam® (STB) Non-Contact Reversing System

Places an invisible beam across door opening, that reverses the door during down travel to the fully open position if anything passes through beam.

Safe-T-Reverse® Contact Reversing System

Automatically stops and reverses a closing door within 2 seconds of contact with an object.

Safe-T-Stop® Timed Reversed System

Automatically opens a closing door, if door does not close within 30 seconds.

ForceGuard® Control

Used to set the force required for opening and closing door. For maximum safety, set the minimum force required to fully open and close door.

Automatic Lighting System

Light bulbs up to 60 Watts max. , used for safer entries and exits. The lights turn on when door is activated and automatically turn off 4.5 minutes later.

Manual Emergency Release

Allows the garage door to be opened or closed manually for emergencies or maintenance.

4

For Help, call 1-800-35-GENIE or visit www.geniecompany.com

Image 4
Contents 2060 3060 Savethese Instructions Operation and Maintenance Manual Your Garage Door Opener Documentation PackageImportant Installation Instructions Safety FeaturesThickness Check Check Garage DoorALIGNMENT, Operation Balance Check Check Door Header Area Check Check Power Head Power SourceMounting Area Perforated Angle Iron Conduit WoodE G Check Check SAFE-T-BEAMMounting Bracket Location Maintenance and Adjustments Setting Contact Reverse Function 4 board laid flatAccessories Remote ControlsProgramming 1 Programming Pop off the back of the transmitterInstall Light Bulbs and Lens Install LightbulbsLubricant As needed Replace lightbulbsSafe-T-Beam System Self-Diagnostic Troubleshooting Check wiringPower has been interrupted Remove power and reapply Wiring to Source missing or badGeneral Troubleshooting Wiring Diagram Opening Cover May Cause Electric ShockPower Head Assembly Parts IdentificationParts List cont’ Ordering Instructions 2060-3060 eng.qxd 11/9/05 1102 AM Avec Télécommande Intellicode ET ÍndiceTable DES Matières 3559935907Genie Company Garantía Limitada Manual de funcionamiento y mantenimiento Perspectiva DE Peligros Potenciales Características DE SeguridadCinta métrica de más de 12 Lápiz Escalera Nivel Lista DE Verificacion DE PreinstalacionRuban à mesurer de 3,6 m Crayon Echelle Niveau Verificación del Paso 4 Verifque EL Área DEL Verificación del Paso 3 Mida LA Altura DE LAContrôle Étape Figura 5 Verifique el lugar de la caja de control Bandes perforéesContrôle Étape 8 Outils Recommandes Figura 8 Herramientas recomendadasMaintenance ET Réglages JustesFijando el interruptor limitador de cerrar Figura Oprima la consola de pared para cerrar la puerta del garajeAbra la puerta del garaje usando la consola de pared Cierre la puerta usando la consola de paredAccessoires AccesoriosLes télécommandes sont programmées individuellement Se recomienda las bombillas reforzadas de 130 voltiosMaintenance Périodique Instrucciones DE Seguridad ImportantesImportantes Consignes DE Sécurité Equilibre la puerta Cierre la puertaOperación normal No requiere ninguna Fonctionnement normal AucuneInvestigación de averías generales Résolutions des problèmes Diagrama DE Conexiones Schéma DE CâblageCaja de control De la tête motoriséeLista de piezas Conjunto del rielRail Liste des pièces