Check Step 3: MEASURE GARAGE DOOR HEIGHT

Measure garage door height (7'-6", 8'-0", or taller) with tape measure.

AIf door height is 7'-6" or less, continue with Check Step 4.

BIf door height is 8'-0", you need a Rail Extension

Kit. (Figure 3) (See Accessories Order Form, page 19).

CIf door height is taller than 8'-0", you will require a different rail. Contact an Genie Customer Service Representative at 1-800-35-GENIE.

Check Step 4: CHECK DOOR HEADER AREA

NOTE

The header is a heavily reinforced section of the wall just above the top of the garage door opening.

AFind vertical center line of door and header:

Close door.

Measure door width at top.

Mark a point at center of door and on header directly above door. Draw a center line to connect points.

BFind Header Bracket mounting height (Figure 4): (Do not attach Header Bracket).

Raise door, watching top edge of door and stop door when its edge reaches its highest point.

Measure distance (“H”) from top edge of door to floor.

For sectional doors, add 2-1/2" to “H”. Mark a point on center line. Bottom of Header Bracket will be installed here.

For one-piece doors, add 6" to “H”. Mark this point on center line. Bottom of Header Bracket will be installed here.

NOTE

For both types of doors:

If the ceiling in your garage is so low that there is not at least a 3" space above the Header Bracket mounting point, contact a Genie Factory Authorized Dealer.

If a door spring is in the way, place the Header

Bracket above the spring. Do Not move the door spring.

WARNING:

Door springs are under extremely high tension and should be handled ONLY by a trained professional.

CCheck wall for a stud or a solid header at your mark:

(If checking a finished wall, a stud finder may be helpful).

If location is above Header, a 2" x 6" board must be screwed to studs beside your mark with at least two Lag Screws and Flat Washers (not provided).

Transfer your mark to new mounting board.

Rail Extension for

8' door

Figure 3 Rail Extension Kit

SECTIONAL DOOR

H + 2-1/2”

HEADER

H

ONE-PIECE DOOR

H + 6”

HEADER

H

Figure 4 Find Highest Point of Travel

6

For Help, call 1-800-35-GENIE or visit www.geniecompany.com

Image 6
Contents 2060 3060 Savethese Instructions Operation and Maintenance Manual Your Garage Door Opener Documentation PackageImportant Installation Instructions Safety FeaturesCheck Check Garage Door ThicknessALIGNMENT, Operation Balance Check Check Door Header Area Mounting Area Check Check Power HeadPower Source Perforated Angle Iron Conduit WoodCheck Check SAFE-T-BEAM E GMounting Bracket Location Maintenance and Adjustments Setting Contact Reverse Function 4 board laid flatProgramming 1 Programming AccessoriesRemote Controls Pop off the back of the transmitterInstall Light Bulbs and Lens Install LightbulbsLubricant As needed Replace lightbulbsPower has been interrupted Remove power and reapply Safe-T-Beam System Self-Diagnostic TroubleshootingCheck wiring Wiring to Source missing or badGeneral Troubleshooting Wiring Diagram Opening Cover May Cause Electric ShockPower Head Assembly Parts IdentificationParts List cont’ Ordering Instructions 2060-3060 eng.qxd 11/9/05 1102 AM Table DES Matières Avec Télécommande Intellicode ETÍndice 3559935907Genie Company Garantía Limitada Manual de funcionamiento y mantenimiento Perspectiva DE Peligros Potenciales Características DE SeguridadLista DE Verificacion DE Preinstalacion Cinta métrica de más de 12 Lápiz Escalera NivelRuban à mesurer de 3,6 m Crayon Echelle Niveau Verificación del Paso 3 Mida LA Altura DE LA Verificación del Paso 4 Verifque EL Área DELContrôle Étape Figura 5 Verifique el lugar de la caja de control Bandes perforéesContrôle Étape 8 Outils Recommandes Figura 8 Herramientas recomendadasFijando el interruptor limitador de cerrar Figura Maintenance ET RéglagesJustes Oprima la consola de pared para cerrar la puerta del garajeAbra la puerta del garaje usando la consola de pared Cierre la puerta usando la consola de paredAccessoires AccesoriosLes télécommandes sont programmées individuellement Se recomienda las bombillas reforzadas de 130 voltiosImportantes Consignes DE Sécurité Maintenance PériodiqueInstrucciones DE Seguridad Importantes Equilibre la puerta Cierre la puertaOperación normal No requiere ninguna Fonctionnement normal AucuneInvestigación de averías generales Résolutions des problèmes Diagrama DE Conexiones Schéma DE CâblageCaja de control De la tête motoriséeLista de piezas Conjunto del rielRail Liste des pièces