Installation Instructions
SIGNALS
LOST TIME SIGNAL
If time is lost on the display due to power interruption, the blue indicator light will flash 4 times every second, until the present time of day is entered.
LOW SALT SIGNAL
When the DAYS TO EMPTY drops to 15, the blue indicator light and DAYS TO EMPTY in the display will flash every second and the alarm will beep every 30 seconds (from 8:00 AM to 8:00 PM), to notify the user that the unit is running low on salt. As soon as any button is pressed, the alarm will stop beeping. The blue indicator light and DAYS TO EMPTY will continue to flash. Once salt is added to the brine tank and the SALT LEVEL is reset, the DAYS TO EMPTY will be reset.
ERROR SIGNALS
If there is an error code detected, the blue indicator light will flash 4 times every second, the display will flash Err and the alarm will beep
every 30 seconds (from 8:00 AM to
8:00 PM) to signal that the softener requires service. The alarm can be turned off by pressing any button, but the blue indicator light and display will continue to flash.
See page 18 for information to assist in troubleshooting error codes. Once the problem is corrected, disconnect the transformer from the wall outlet momentarily, and plug it back in. The normal display will appear. The motor may run for several minutes, as the unit resets. If the problem is not corrected, the error code will reappear in 6 minutes.
BLUE INDICATOR LIGHT
Steady blue light indicates that the unit is working correctly. The light flashes when the unit needs attention from the user.
•Light flashes and DAYS TO EMPTY
•Light flashes and Err is in the
•Light will also flash when power to the unit has been interrupted. Check the PRESENT TIME setting.
13