GE GNSH45E, GXSH39E installation instructions Safety Precautions

Page 2

IMPORTANT SAFETY INFORMATION.

READ ALL INSTRUCTIONS BEFORE USING.

WARNING!

For your safety, the information in this manual must be followed to minimize the risk of electric shock, property damage or personal injury.

SAFETY PRECAUTIONS

Check and comply with your state and local codes. You must follow these guidelines.

Use care when handling the water softening system. Do not turn upside down, drop, drag or set on sharp protrusions.

Water softening systems using sodium chloride (salt) for recharge add sodium to the water. Persons on sodium restricted diets should consider the added sodium as part of their overall intake. Potassium chloride can be used as an alternative to sodium chloride in your softener.

The water softening system works on 24 volt-60 Hz electrical power only. Be sure to use only the included transformer.

Transformer must be plugged into an indoor 120 volt, grounded outlet only.

Use clean water softening salts only, at least 99.5% pure. NUGGET, PELLET or coarse SOLAR salts are recommended. Do not use rock, block, granulated or ice cream making salts. They contain dirt and sediments, or mush and cake, and will create maintenance problems.

Keep the salt hole cover in place on the softener unless servicing the unit or refilling with salt.

WARNING: Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.

PROPER INSTALLATION

This water softening system must be properly installed and located in accordance with the Installation Instructions before it is used.

Install or store where it will not be exposed to temperatures below freezing or exposed to any type of weather. Water freezing in the system will break it. Do not attempt to treat water over 100°F.

Do not install in direct sunlight. Excessive sun or heat may cause distortion or other damage to non-metallic parts.

Properly ground to conform with all governing codes and ordinances.

Use only lead-free solder and flux for all sweat-solder connections, as required by state and federal codes.

The water softening system requires a minimum water flow of three gallons per minute at the inlet. Maximum allowable inlet water pressure is 125 psi. If daytime pressure is over 80 psi, nighttime pressure may exceed the maximum. Use a pressure reducing valve to reduce the flow if necessary.

Softener resins may degrade in the presence of chlorine above 2 ppm. If you have chlorine in excess of this amount, you may experience reduced life of the resin. In these conditions, you may wish to consider purchasing a GE point-of-entry household filtration system with a chlorine reducing filter.

WARNING: Discard all unused parts and packaging material after installation. Small parts remaining after the installation could be a choke hazard.

READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.

SAVE THESE INSTRUCTIONS

2

Image 2
Contents 7283950 215C1173P025 49-50180-112-06 JR Safety InformationCare and Cleaning Write the model and serial numbers here Model #Safety Precautions Read these instructions completely and carefully Before Beginning InstallationImportant Installation Recommendations Transit Where to Install the SoftenerUnpacking and Inspection Plan HOW YOU will Install the Softener OUTBefore YOU Begin Install Bypass ValveInstall Drain Fitting Push all the wayConnect and RUN the Valve Drain Hose Plumb in and OUT Pipes to and from SoftenerInstall the Brine Tank Connecting a Rigid Valve Drain TubeWith salt Install Grounding ClampADD Water and Salt to the Brine Tank SET Present Time of DAY Connect to Electrical PowerProgramming the Control SET Water Hardness NumberDays to Empty SET Recharge Starting TimeSET Salt Level Optional Control Settings Feature Other Data DisplaysLOW Salt Signal SignalsLost Time Signal Error Signals19″ 471⁄2″ 411⁄4″ 16″ Sanitizing ProceduresImportant Press and hold for 3 seconds About the water softener system Cleaning the Nozzle and Venturi Assembly Breaking a Salt BridgeFeature/Service Automatic Electronic Diagnostics Feature Optional Recharge ControlsFeature Memory Normal Operation, Control DisplaysTo remove an error code 1. Unplug transformer Service Electronic Demand Time Features and ServiceService Timer/Softener, Service Checkout Procedure ERRService Set Model F or P Code Operation of DiagnosticsIf the water softening system does not draw brine, check Checking the Salt Storage Level and Refilling Care and cleaning of the water softening systemCleaning Iron Out of the Water Softening System However, you must keep the tank supplied with saltNo soft water Before you call for service…What To Do Taken not plumbed to soft waterExcessive/high level Water in brine tankBrown/yellow Brown/yellow colored Water after installationSalty tasting or Colored water Resin beads showingPage Page Parts list 151 Parts catalog General Electric Parts CatalogSupport Screen Warrantor General Electric Company. Louisville, KY What Is Not CoveredFor The Period We Will Replace One Year GE Water Softening System Warranty. For Customers in CanadaWarrantor Mabe Canada INC De averías Cómo limpiar la ensambladuraDe agua Cuidado y limpieza Advertencia Advertencia No use con aguaRecomendaciones Importantes Para LA Instalación Lea estas instrucciones completa y cuidadosamenteHerramientas Y Materiales Necesarios Para LA Instalación Desempacado E InspecciónDonde Instalar EL Descalcificador Planifique LA Instalación DEL Descalcificador Ilustración DE Instalación NormalRemueva el tapón plástico de embalaje y el cable de la Antes DE ComenzarInstale LA Válvula DE Bypass Como se muestraRetire el descalcificador del lugar de instalación Cerciórese de cumplir con los códigos localesSalmuera Y LA Manguera Instale LOS Accesorios DESobreflujo DEL Tanque DE ContInstale LA Abrazadera DE Tierra Cierre todos los grifos de aguaAjuste LA Hora DEL DÍA Conectar a LA Fuente EléctricaProgramación DEL Control Hora actualDe recarga Ajuste EL Nivel DE SALDías Hasta Vacío De salCaracterística Otras Visualizaciones DE Datos Ajustes Opcionales DE ControlEficiencia DE LA SAL DEL SistemaSeñal DE Hora Perdida Señales DE ErrorSeñals Señal DE Bajo Nivel DE SALNi infectarán su suministro de agua ni causarán que Procedimientos DE DesinfecciónEn la fábrica se siguen los cuidados para mantener Sobre el sistema de descalcificación de agua Cómo romper un puente de sal Cómo limpiar la ensambladura de la boquilla y el Venturi Función Memoria Operación normal, Pantalla de controlFunción Controles opcionales de recargado Característica/Servicio Diagnóstico electrónico automáticoVisualizado Servicio Diagnóstico electrónico iniciado manualmente Vea la sección Programación del controlServicio Configurar el código del modelo F o P Servicio Inspección manual del avance de la recargaCuidado y limpieza del sistema de descalcificación de agua Cuándo rellenar con sal Si una luz indicadoraAntes de llamar para solicitar servicio… Qué hacerVeces el agua Luz intermitente azul Lista de partes 151 Catálogo de partes Catálogo DE Partes DE General ElectricNO. Refer Lo que no está cubierto Garantía GE para el Sistema de Descalcificación de AguaPor el período de Reemplazamos Garantías ampliadas Soporte al Consumidor Página Web de GE AppliancesSolicite una reparación Piezas y accesoriosConsumer Support GE Appliances Website Schedule ServiceParts and Accessories Real Life Design Studio