GE GNSH45E Before YOU Begin, Install Bypass Valve, Install Drain Fitting, Push all the way

Page 6

Installation Instructions

BEFORE YOU BEGIN

Turn off the gas or electric supply to the water heater, in the possibility that the water heater may be drained while draining pipes.

Turn off the water supply to pipes to be cut and drain the house water pipes.

Open both hot and cold faucets at the lowest location possible.

NOTE: For easier installation, remove the top cover. Release 2 clips at rear of cover. Rotate cover forward and lift up.

1INSTALL BYPASS VALVE

Remove plastic shipping plug and wire from valve

outlet.Turbine

Valve outlet

Turbine shaft and support

NOTE: Be sure the turbine and support are firmly in place in the valve outlet. Blow into the valve port and observe the turbine for free rotation.

Push the bypass valve (lubricate o-ring seals with silicone grease) into both ports of the valve as shown.

Clips

O-rings

NPT adapter

O-ring seal goes into the outer groove only. The clip snaps into the inner groove (see below).

Snap the 2 large plastic clips in place, from the top down, as shown.

 

 

SIDE

Clip

 

 

 

VIEW

END

 

 

 

 

VIEW

 

 

Valve body

Bypass valve

 

 

inlet or outlet

(push all the way in)

 

Push the NPT adapters (lubricate o-ring seals with

 

 

silicone grease) into both ports of the valve as

 

 

shown

 

 

Snap the 2 large plastic clips in place, from the

 

 

side, as shown.

6

 

 

 

2INSTALL DRAIN FITTING

Push the drain fitting (lubricate o-ring seals with silicone grease) into the part of the valve as shown.

Snap the large plastic clip in place, from the top down as shown. Be sure the clip snaps into place. Pull on the drain fitting to make sure it is held securely in place.

Drain fitting

3MOVE THE SOFTENER ASSEMBLY INTO INSTALLATION POSITION

Before sliding softener in position, be sure the installation surface is level and smooth. Sharp objects under the tank may puncture it. If needed, place the tank on a section of 3/4thick (minimum) plywood. Then, place shims under the plywood as needed to level the softener. Slide softener into position.

Image 6
Contents 7283950 215C1173P025 49-50180-112-06 JR Safety InformationCare and Cleaning Write the model and serial numbers here Model #Safety Precautions Before Beginning Installation Important Installation RecommendationsRead these instructions completely and carefully Where to Install the Softener Unpacking and InspectionTransit Plan HOW YOU will Install the Softener OUTBefore YOU Begin Install Bypass ValveInstall Drain Fitting Push all the wayConnect and RUN the Valve Drain Hose Plumb in and OUT Pipes to and from SoftenerInstall the Brine Tank Connecting a Rigid Valve Drain TubeInstall Grounding Clamp ADD Water and Salt to the Brine TankWith salt SET Present Time of DAY Connect to Electrical PowerProgramming the Control SET Water Hardness NumberSET Recharge Starting Time SET Salt LevelDays to Empty Optional Control Settings Feature Other Data DisplaysLOW Salt Signal SignalsLost Time Signal Error SignalsSanitizing Procedures Important Press and hold for 3 seconds19″ 471⁄2″ 411⁄4″ 16″ About the water softener system Cleaning the Nozzle and Venturi Assembly Breaking a Salt BridgeFeature/Service Automatic Electronic Diagnostics Feature Optional Recharge ControlsFeature Memory Normal Operation, Control DisplaysTo remove an error code 1. Unplug transformer Service Electronic Demand Time Features and ServiceService Timer/Softener, Service Checkout Procedure ERRService Set Model F or P Code Operation of DiagnosticsIf the water softening system does not draw brine, check Checking the Salt Storage Level and Refilling Care and cleaning of the water softening systemCleaning Iron Out of the Water Softening System However, you must keep the tank supplied with saltNo soft water Before you call for service…What To Do Taken not plumbed to soft waterExcessive/high level Water in brine tankBrown/yellow Brown/yellow colored Water after installationSalty tasting or Colored water Resin beads showingPage Page Parts list 151 Parts catalog General Electric Parts CatalogSupport Screen What Is Not Covered For The Period We Will ReplaceWarrantor General Electric Company. Louisville, KY GE Water Softening System Warranty. For Customers in Canada Warrantor Mabe Canada INCOne Year Cómo limpiar la ensambladura De agua Cuidado y limpiezaDe averías Advertencia Advertencia No use con aguaRecomendaciones Importantes Para LA Instalación Lea estas instrucciones completa y cuidadosamenteDesempacado E Inspección Donde Instalar EL DescalcificadorHerramientas Y Materiales Necesarios Para LA Instalación Planifique LA Instalación DEL Descalcificador Ilustración DE Instalación NormalRemueva el tapón plástico de embalaje y el cable de la Antes DE ComenzarInstale LA Válvula DE Bypass Como se muestraRetire el descalcificador del lugar de instalación Cerciórese de cumplir con los códigos localesSalmuera Y LA Manguera Instale LOS Accesorios DESobreflujo DEL Tanque DE ContInstale LA Abrazadera DE Tierra Cierre todos los grifos de aguaAjuste LA Hora DEL DÍA Conectar a LA Fuente EléctricaProgramación DEL Control Hora actualDe recarga Ajuste EL Nivel DE SALDías Hasta Vacío De salCaracterística Otras Visualizaciones DE Datos Ajustes Opcionales DE ControlEficiencia DE LA SAL DEL SistemaSeñal DE Hora Perdida Señales DE ErrorSeñals Señal DE Bajo Nivel DE SALProcedimientos DE Desinfección En la fábrica se siguen los cuidados para mantenerNi infectarán su suministro de agua ni causarán que Sobre el sistema de descalcificación de agua Cómo romper un puente de sal Cómo limpiar la ensambladura de la boquilla y el Venturi Función Memoria Operación normal, Pantalla de controlFunción Controles opcionales de recargado Característica/Servicio Diagnóstico electrónico automáticoVisualizado Servicio Diagnóstico electrónico iniciado manualmente Vea la sección Programación del controlServicio Configurar el código del modelo F o P Servicio Inspección manual del avance de la recargaCuidado y limpieza del sistema de descalcificación de agua Cuándo rellenar con sal Si una luz indicadoraAntes de llamar para solicitar servicio… Qué hacerVeces el agua Luz intermitente azul Lista de partes 151 Catálogo de partes Catálogo DE Partes DE General ElectricNO. Refer Garantía GE para el Sistema de Descalcificación de Agua Por el período de ReemplazamosLo que no está cubierto Garantías ampliadas Soporte al Consumidor Página Web de GE AppliancesSolicite una reparación Piezas y accesoriosConsumer Support GE Appliances Website Schedule ServiceParts and Accessories Real Life Design Studio