Normal Operation, Control Displays

During normal operation, the present time of day and AM or PM and DAYS TO EMPTY show in the control display area. When the demand computer determines a recharge is needed, RECHARGE TONIGHT begins to flash in the display along with the present time. RECHARGE TONIGHT flashes until the next recharge start time, then changes to RECHARGE, which flashes until the recharge is over.

Feature: Optional Recharge Controls

Sometimes, a manually started recharge may be desired or needed. Two examples:

You have used more water than usual (house guests, extra washing, etc.) and you may run out of soft water before the next recharge.

The system ran out of salt.

Use one of the following features to start a recharge immediately, or at the next preset recharge start time.

RECHARGE TONIGHT

Touch (do not hold) the RECHARGE button. RECHARGE TONIGHT flashes in the control display area. A recharge will occur at the next preset recharge start time. If you decide to cancel this recharge, touch the same button once more.

RECHARGE

Press and hold the RECHARGE button until RECHARGE starts to flash in the control display area. The water softening system begins an immediate recharge and, when over in about two hours, you will have a new supply of soft water. Once started, you cannot cancel this recharge.

Feature: Memory

If electrical power to the water softening system is interrupted, the control display is blank, and the blue indicator light is off, but the control keeps correct time for about 6 hours. When power is restored, you have to reset the present time only if the display and blue indicator light are flashing. All other settings are maintained and never require resetting unless a change is desired.

If the time is flashing after a long power outage, the water softening system continues to work as it should to provide you with soft water. However, recharge may occur at the wrong time of day until you reset the control to the correct time

of day.

Feature/Service: Automatic Electronic Diagnostics

The control computer has a self-diagnostic function for the electrical system (except input power and water meter). The computer monitors the electronic components and circuits for correct operation. If a malfunction occurs,

an error code appears in the control display.

The chart on Error Codes shows the error codes that could appear and possible reasons for each code. See Manually Initiated Electronics Diagnostics to further isolate the defect.

17

Image 17
Contents Care and Cleaning Safety Information7283950 215C1173P025 49-50180-112-06 JR Write the model and serial numbers here Model #Safety Precautions Read these instructions completely and carefully Before Beginning InstallationImportant Installation Recommendations Transit Where to Install the SoftenerUnpacking and Inspection OUT Plan HOW YOU will Install the SoftenerInstall Drain Fitting Install Bypass ValveBefore YOU Begin Push all the wayPlumb in and OUT Pipes to and from Softener Connect and RUN the Valve Drain HoseConnecting a Rigid Valve Drain Tube Install the Brine TankWith salt Install Grounding ClampADD Water and Salt to the Brine Tank Programming the Control Connect to Electrical PowerSET Present Time of DAY SET Water Hardness NumberDays to Empty SET Recharge Starting TimeSET Salt Level Feature Other Data Displays Optional Control SettingsLost Time Signal SignalsLOW Salt Signal Error Signals19″ 471⁄2″ 411⁄4″ 16″ Sanitizing ProceduresImportant Press and hold for 3 seconds About the water softener system Breaking a Salt Bridge Cleaning the Nozzle and Venturi AssemblyFeature Memory Feature Optional Recharge ControlsFeature/Service Automatic Electronic Diagnostics Normal Operation, Control DisplaysService Timer/Softener, Service Checkout Procedure Service Electronic Demand Time Features and ServiceTo remove an error code 1. Unplug transformer ERROperation of Diagnostics Service Set Model F or P CodeIf the water softening system does not draw brine, check Cleaning Iron Out of the Water Softening System Care and cleaning of the water softening systemChecking the Salt Storage Level and Refilling However, you must keep the tank supplied with saltWhat To Do Before you call for service…No soft water Taken not plumbed to soft waterWater in brine tank Excessive/high levelSalty tasting or Brown/yellow colored Water after installationBrown/yellow Colored water Resin beads showingPage Page Parts list 151 General Electric Parts Catalog Parts catalogSupport Screen Warrantor General Electric Company. Louisville, KY What Is Not CoveredFor The Period We Will Replace One Year GE Water Softening System Warranty. For Customers in CanadaWarrantor Mabe Canada INC De averías Cómo limpiar la ensambladuraDe agua Cuidado y limpieza Advertencia No use con agua AdvertenciaLea estas instrucciones completa y cuidadosamente Recomendaciones Importantes Para LA InstalaciónHerramientas Y Materiales Necesarios Para LA Instalación Desempacado E InspecciónDonde Instalar EL Descalcificador Ilustración DE Instalación Normal Planifique LA Instalación DEL DescalcificadorInstale LA Válvula DE Bypass Antes DE ComenzarRemueva el tapón plástico de embalaje y el cable de la Como se muestraCerciórese de cumplir con los códigos locales Retire el descalcificador del lugar de instalaciónSobreflujo DEL Tanque DE Instale LOS Accesorios DESalmuera Y LA Manguera ContCierre todos los grifos de agua Instale LA Abrazadera DE TierraProgramación DEL Control Conectar a LA Fuente EléctricaAjuste LA Hora DEL DÍA Hora actualDías Hasta Vacío Ajuste EL Nivel DE SALDe recarga De salEficiencia DE LA SAL Ajustes Opcionales DE ControlCaracterística Otras Visualizaciones DE Datos DEL SistemaSeñals Señales DE ErrorSeñal DE Hora Perdida Señal DE Bajo Nivel DE SALNi infectarán su suministro de agua ni causarán que Procedimientos DE DesinfecciónEn la fábrica se siguen los cuidados para mantener Sobre el sistema de descalcificación de agua Cómo romper un puente de sal Cómo limpiar la ensambladura de la boquilla y el Venturi Función Controles opcionales de recargado Operación normal, Pantalla de controlFunción Memoria Característica/Servicio Diagnóstico electrónico automáticoVisualizado Vea la sección Programación del control Servicio Diagnóstico electrónico iniciado manualmenteServicio Inspección manual del avance de la recarga Servicio Configurar el código del modelo F o PCuándo rellenar con sal Si una luz indicadora Cuidado y limpieza del sistema de descalcificación de aguaQué hacer Antes de llamar para solicitar servicio…Veces el agua Luz intermitente azul Lista de partes 151 Catálogo DE Partes DE General Electric Catálogo de partesNO. Refer Lo que no está cubierto Garantía GE para el Sistema de Descalcificación de AguaPor el período de Reemplazamos Solicite una reparación Soporte al Consumidor Página Web de GE AppliancesGarantías ampliadas Piezas y accesoriosParts and Accessories Schedule ServiceConsumer Support GE Appliances Website Real Life Design Studio