GE GXSH39E, GNSH45E Service Set Model F or P Code, Operation of Diagnostics

Page 19

ge.com

Service: Manually Initiated Electronics Diagnostics

1. To enter diagnostics, press and hold

SALT

 

the MODE button for 3 seconds until

LEVEL

 

 

 

 

 

the Low Salt Alarm screen shows.

 

 

2. Press the MODE button 2 times

SALT

 

 

 

to advance through Low Salt Alarm

LEVEL

 

 

 

 

 

and Salt Efficiency options. See

 

 

Programming the Control for

 

 

details on these two options.

 

 

3. OPERATION OF DIAGNOSTICS

 

 

Motor Position

Valveswitch position

SALT￿

LEVEL

Water meter

Valve Position – Press the RECHARGE button to initiate a recharge cycle. Press again to manually index valve to next position. See Service: Manually Advance Recharge Check for details.

0 – Service

1 – Fill

2 – Brine

3 – Backwash

4 – Fast Rinse

Motor Operation – Two dashes will circulate around when motor should be running.

Position Switch Operation –

– Closed valve rotating to next position

– Open valve in position, service, fill, brine, etc.

Water Meter – Indicates whether water is flowing through valve.

Motor

Position switch

 

Sensor

 

housing

 

Turbine

Valve

Turbine support

and shaft

outlet

 

000 indicates no water is flowing through the valve

Open nearby soft water faucet

000 to 141 (continual) shows water is flowing. Display repeats for each gallon of water passing through the meter. Control will beep at every gallon.

If there is no reading in the display, with faucet open, check the sensor. Pull the sensor from the valve outlet port, and pass a small magnet in front of the sensor.

Counter should index in the display. If counter does not index, check to make sure harness is connected to board properly. If there is a reading in the display, there may be a problem associated with the turbine. Turn off water supply, close the bypass valve and disconnect bypass valve from body. Check turbine for binding or restriction due to debris. If this does not correct the problem, the Timer, Sensor or Turbine may require replacement.

4.Historical data about the softener is available.

Press and hold the UP button to display the number of days this control has had electrical power applied.

Press and hold the DOWN button to display the number of recharges initiated by this control since the model code number was entered.

5.Press the MODE button to return to normal operation and display.

Service: Set Model (F or P) Code

1.To change or check model code, first press and hold the MODE button for 3 seconds until the Low Salt Alarm screen shows.

2. Press and hold the MODE button again

SALT

for 3 seconds. A display with

at

LEVEL

 

the top will appear.

3.Press the UP or DOWN buttons to select the correct model code.

P39–GXSH39E or P45–GNSH45E

4.Press the MODE button one time to return to normal operation and display. If the model code was changed:

the display will go blank momentarily, then display the model code entered.

the display will then return to the set present time display, and the blue indicator light will flash. The control will have to be reprogrammed. See Programming the Control.

NOTE: If the control is left in any of the above diagnostic displays, or a flashing display when setting time, hardness, etc., it will revert back to the normal display in 4 minutes.

19

Image 19
Contents Write the model and serial numbers here Model # Safety InformationCare and Cleaning 7283950 215C1173P025 49-50180-112-06 JRSafety Precautions Important Installation Recommendations Before Beginning InstallationRead these instructions completely and carefully Unpacking and Inspection Where to Install the SoftenerTransit OUT Plan HOW YOU will Install the SoftenerPush all the way Install Bypass ValveInstall Drain Fitting Before YOU BeginPlumb in and OUT Pipes to and from Softener Connect and RUN the Valve Drain HoseConnecting a Rigid Valve Drain Tube Install the Brine TankADD Water and Salt to the Brine Tank Install Grounding ClampWith salt SET Water Hardness Number Connect to Electrical PowerProgramming the Control SET Present Time of DAYSET Salt Level SET Recharge Starting TimeDays to Empty Feature Other Data Displays Optional Control SettingsError Signals SignalsLost Time Signal LOW Salt SignalImportant Press and hold for 3 seconds Sanitizing Procedures19″ 471⁄2″ 411⁄4″ 16″ About the water softener system Breaking a Salt Bridge Cleaning the Nozzle and Venturi AssemblyNormal Operation, Control Displays Feature Optional Recharge ControlsFeature Memory Feature/Service Automatic Electronic DiagnosticsERR Service Electronic Demand Time Features and ServiceService Timer/Softener, Service Checkout Procedure To remove an error code 1. Unplug transformerOperation of Diagnostics Service Set Model F or P CodeIf the water softening system does not draw brine, check However, you must keep the tank supplied with salt Care and cleaning of the water softening systemCleaning Iron Out of the Water Softening System Checking the Salt Storage Level and RefillingTaken not plumbed to soft water Before you call for service…What To Do No soft waterWater in brine tank Excessive/high levelColored water Resin beads showing Brown/yellow colored Water after installationSalty tasting or Brown/yellowPage Page Parts list 151 General Electric Parts Catalog Parts catalogSupport Screen For The Period We Will Replace What Is Not CoveredWarrantor General Electric Company. Louisville, KY Warrantor Mabe Canada INC GE Water Softening System Warranty. For Customers in CanadaOne Year De agua Cuidado y limpieza Cómo limpiar la ensambladuraDe averías Advertencia No use con agua AdvertenciaLea estas instrucciones completa y cuidadosamente Recomendaciones Importantes Para LA InstalaciónDonde Instalar EL Descalcificador Desempacado E InspecciónHerramientas Y Materiales Necesarios Para LA Instalación Ilustración DE Instalación Normal Planifique LA Instalación DEL DescalcificadorComo se muestra Antes DE ComenzarInstale LA Válvula DE Bypass Remueva el tapón plástico de embalaje y el cable de laCerciórese de cumplir con los códigos locales Retire el descalcificador del lugar de instalaciónCont Instale LOS Accesorios DESobreflujo DEL Tanque DE Salmuera Y LA MangueraCierre todos los grifos de agua Instale LA Abrazadera DE TierraHora actual Conectar a LA Fuente EléctricaProgramación DEL Control Ajuste LA Hora DEL DÍADe sal Ajuste EL Nivel DE SALDías Hasta Vacío De recargaDEL Sistema Ajustes Opcionales DE ControlEficiencia DE LA SAL Característica Otras Visualizaciones DE DatosSeñal DE Bajo Nivel DE SAL Señales DE ErrorSeñals Señal DE Hora PerdidaEn la fábrica se siguen los cuidados para mantener Procedimientos DE DesinfecciónNi infectarán su suministro de agua ni causarán que Sobre el sistema de descalcificación de agua Cómo romper un puente de sal Cómo limpiar la ensambladura de la boquilla y el Venturi Característica/Servicio Diagnóstico electrónico automático Operación normal, Pantalla de controlFunción Controles opcionales de recargado Función MemoriaVisualizado Vea la sección Programación del control Servicio Diagnóstico electrónico iniciado manualmenteServicio Inspección manual del avance de la recarga Servicio Configurar el código del modelo F o PCuándo rellenar con sal Si una luz indicadora Cuidado y limpieza del sistema de descalcificación de aguaQué hacer Antes de llamar para solicitar servicio…Veces el agua Luz intermitente azul Lista de partes 151 Catálogo DE Partes DE General Electric Catálogo de partesNO. Refer Por el período de Reemplazamos Garantía GE para el Sistema de Descalcificación de AguaLo que no está cubierto Piezas y accesorios Soporte al Consumidor Página Web de GE AppliancesSolicite una reparación Garantías ampliadasReal Life Design Studio Schedule ServiceParts and Accessories Consumer Support GE Appliances Website