2.4Connection to Gas Line
The H52 Series has received the CE mark for the countries and gas categories indicated in the accompanying table. NOTE: The nominal heat input (Qn) is 21kW except for AT, DE, LU, and for category 3B/P under 50 mbar, which is 23kW.
CE Approved Gas Categories by Country*
COUNTRIES | CATEGORIES | GAS | PRESSURE (mbar) | |
AUSTRIA (AT) | II2H3B/P | G20 | 20 | |
G30, G31 | 50 | |||
|
| |||
BELGIUM (BE) | I2E(R)B | G20, G25 | 20, 25 | |
I3+ | G30, G31 | |||
| ||||
DENMARK (DK) | II2H3B/P | G20 | 20 | |
G30, G31 | 30 | |||
|
| |||
| II2Esi3+ | G20, G25 | 20, 25 | |
FRANCE (FR) | G30, G31 | |||
| ||||
II2Esi3P | G20, G25 | 20, 25 | ||
| ||||
| G31 | 50 | ||
|
| |||
FINLAND (FI) | II2H3B/P | G20 | 20 | |
G30, G31 | 30 | |||
|
| |||
| II2ELL3B/P | G20, G25 | 20 | |
GERMANY (DE) | G30, G31 | 50 | ||
| ||||
| I3P | G31 | 50 | |
GREECE (GR) | II2H3+ | G20 | 20 | |
G30, G31 | ||||
|
| |||
ITALY (IT) | II2H3+ | G20 | 20 | |
G30, G31 | ||||
|
| |||
IRELAND (IE) | II2H3+ | G20 | 20 | |
G30, G31 | ||||
|
| |||
LUXEMBOURG (LU) | II2E3B/P | G20 | 20 | |
G30, G31 | 50 | |||
|
| |||
| II2L3P | G25 | 25 | |
NETHERLANDS (NL) | G31 | 50 | ||
| ||||
II2L3B/P | G25 | 25 | ||
| ||||
| G30, G31 | 30 | ||
|
| |||
NORWAY (NO) | I3B/P | G30, G31 | 30 | |
PORTUGAL (PT) | II2H3+ | G20 | 20 | |
G30, G31 | ||||
|
| |||
| II2H3+ | G20 | 20 | |
SPAIN (ES) | G30, G31 | |||
| ||||
II2H3P | G20 | 20 | ||
| ||||
| G31 | 37, 50 | ||
|
| |||
SWEDEN (SE) | II2H3B/P | G20 | 20 | |
G30, G31 | 30 | |||
|
| |||
UNITED KINGDOM (GB) | II2H3+ | G20 | 20 | |
G30, G31 | ||||
|
| |||
|
|
|
| |
|
|
|
|
* H152-2 units are not approved for G30 (Butane) gas.
The size of the gas line used for installation is very important. If the line is too small, the gas pres- sure at the burner manifold will be low. This may cause slow recovery and delayed ignition. Fry- master recommends the incoming gas supply line be a minimum of 1½” (38 mm) in diameter. Refer to the chart on the following page for the minimum sizes of connection piping.