Frymaster H52 Series warranty Connection to Gas Line, Countries Categories GAS

Page 10

2.4Connection to Gas Line

The H52 Series has received the CE mark for the countries and gas categories indicated in the accompanying table. NOTE: The nominal heat input (Qn) is 21kW except for AT, DE, LU, and for category 3B/P under 50 mbar, which is 23kW.

CE Approved Gas Categories by Country*

COUNTRIES

CATEGORIES

GAS

PRESSURE (mbar)

AUSTRIA (AT)

II2H3B/P

G20

20

G30, G31

50

 

 

BELGIUM (BE)

I2E(R)B

G20, G25

20, 25

I3+

G30, G31

28-30, 37

 

DENMARK (DK)

II2H3B/P

G20

20

G30, G31

30

 

 

 

II2Esi3+

G20, G25

20, 25

FRANCE (FR)

G30, G31

28-30, 37

 

II2Esi3P

G20, G25

20, 25

 

 

G31

50

 

 

FINLAND (FI)

II2H3B/P

G20

20

G30, G31

30

 

 

 

II2ELL3B/P

G20, G25

20

GERMANY (DE)

G30, G31

50

 

 

I3P

G31

50

GREECE (GR)

II2H3+

G20

20

G30, G31

28-30, 37

 

 

ITALY (IT)

II2H3+

G20

20

G30, G31

28-30, 37

 

 

IRELAND (IE)

II2H3+

G20

20

G30, G31

28-30, 37

 

 

LUXEMBOURG (LU)

II2E3B/P

G20

20

G30, G31

50

 

 

 

II2L3P

G25

25

NETHERLANDS (NL)

G31

50

 

II2L3B/P

G25

25

 

 

G30, G31

30

 

 

NORWAY (NO)

I3B/P

G30, G31

30

PORTUGAL (PT)

II2H3+

G20

20

G30, G31

28-30, 37

 

 

 

II2H3+

G20

20

SPAIN (ES)

G30, G31

28-30, 37

 

II2H3P

G20

20

 

 

G31

37, 50

 

 

SWEDEN (SE)

II2H3B/P

G20

20

G30, G31

30

 

 

UNITED KINGDOM (GB)

II2H3+

G20

20

G30, G31

28-30, 37

 

 

 

 

 

 

 

 

 

 

* H152-2 units are not approved for G30 (Butane) gas.

The size of the gas line used for installation is very important. If the line is too small, the gas pres- sure at the burner manifold will be low. This may cause slow recovery and delayed ignition. Fry- master recommends the incoming gas supply line be a minimum of 1½” (38 mm) in diameter. Refer to the chart on the following page for the minimum sizes of connection piping.

2-5

Image 10
Contents OPERATOR’S Manual Frymaster H52 Series GAS Fryer Page Introduction GeneralEuropean Community CE Specific Information Computer InformationWhat to do if your equipment arrives damaged Service Information Installation Instructions General Installation RequirementsNational Code Requirements Caster/Leg Installation Non-CE Standard For Incoming Gas Pressures Connection to Gas Line Countries Categories GASCE Standard Converting to Another Gas Type Gas VatCE Gas Conversion Kits for Units with Gas Valve Non-CE Gas Conversion KitsFrypot Boil-Out Operating Fryers With M100B Cooking Computers ShutdownIntroduction To The M-100B Cooking Computer DescriptionOperating the Computer on Full-Vat Fryers Operating the Computer on Split-Vat Fryers Viewing the Frypot Temperature Actual or SetpointCooking Product Full-Vat or Split-Vat M-100B Computer Problem Condition Indicators Recovery Out of Range REC LockOpen Drain Valve Indication Probe Failure Indication M-100B Computer Set-Up and Programming InstructionsHow to Change the Computer’s Display Language 1 M-100B Computer Setup ModeHow to Enter the Setup Mode How to Configure the Computer for Use on a Gas FryerHow to Change Computer Product/Temperature Displays How to Enter the Program Mode How to Activate or Deactivate the Frypot BOIL-OUT Feature2 M-100B Computer Programming Mode How to Reset the Computer to the Factory DefaultsHow to Change the Cooking Temperature Setpoint How to Enter a Product Name in a Test Menu How to Suppress a Shake, QA, or Duty Function How to Display Use Time Information How to Display the Product Cycle Accumulator InformationHow to Use the Filter Countdown Timer Operating Fryers With Analog Controllers Introduction to the Analog ControllerC D E F G H I J K L M N Analog Controller High-Limit Check Page Filtering Operating the Built-In Filtration System Page Operating the Filter Unit Page Getting the Most Out of Your Filter Page Preventive Maintenance Preventive Maintenance and TroubleshootingTroubleshooting Troubleshooting Fryers with M100B Computers REC LockIgnition Failure Display Remains Blank When ON/OFF Switches are Pressed Troubleshooting Fryers Equipped with Analog Controllers Did burners Troubleshooting Built-in Filtration System Pump does Not RUN