Frymaster H52 Series warranty How to Change Computer Product/Temperature Displays

Page 22

4.Press the switch to save the settings.

5.Press either ON/OFF switch to save the setting and exit the setup mode. Both displays will change to OFF.

How to Configure the Computer for Use on Either a Full-Vat or a Split-Vat Fryer

1.Enter the setup mode. See How to Enter the Setup Mode on Page 3-8.

2.Press and release the switch until 1 vat appears in the left display.

3.Press the right 1 or 2 switch to toggle back and forth between full-vat (yes) or split-vat (NO).

4.Press the switch to save the settings.

5.Press either ON/OFF switch to exit the setup mode. Both displays will change to OFF.

How to Change Computer Product/Temperature Displays

1.Enter the setup mode. See How to Enter the Setup Mode on Page 3-8.

2.Press and release the switch until the word DISPLAY appears in the left display.

3.Press the right 1 or 2 switch to toggle back and forth between constant product display (CONSTANT) or alternating temperature and product display (ALT).

4.Press the switch to save the settings.

5.Press either ON/OFF switch to exit the setup mode. Both displays will change to OFF.

How to Calibrate Computer Temperature to Actual Frypot Temperature

NOTE: For this procedure, actual frypot temperature refers to the temperature of the oil in the frypot as measured with a good-grade thermometer or pyrometer. The computer’s temperature can only be adjusted ±5°F (±3°C). The computer cannot be adjusted to a temperature greater than 375°F (191°C).

1.Enter the setup mode. See How to Enter the Setup Mode on Page 3-8.

2.Press and release the switch until CALIB appears in the display.

3.Press the temperature check switch . The frypot temperature sensed by the computer will be displayed. In split-vat units, the temperatures for each side will be displayed.

4.For the left side of a split-vat: Press the left Fahrenheit or 3 for Celsius). Press the left 2 Fahrenheit or 3 for Celsius).

1switch to go UP a degree (maximum of 5 for switch to go DOWN a degree (maximum of 5 for

3–9

Image 22
Contents OPERATOR’S Manual Frymaster H52 Series GAS Fryer Page Introduction GeneralEuropean Community CE Specific Information Computer InformationWhat to do if your equipment arrives damaged Service Information Installation Instructions General Installation RequirementsNational Code Requirements Caster/Leg Installation Non-CE Standard For Incoming Gas Pressures Connection to Gas Line Countries Categories GASCE Standard Converting to Another Gas Type Gas VatCE Gas Conversion Kits for Units with Gas Valve Non-CE Gas Conversion KitsFrypot Boil-Out Operating Fryers With M100B Cooking Computers ShutdownIntroduction To The M-100B Cooking Computer DescriptionOperating the Computer on Full-Vat Fryers Operating the Computer on Split-Vat Fryers Viewing the Frypot Temperature Actual or SetpointCooking Product Full-Vat or Split-Vat M-100B Computer Problem Condition Indicators Recovery Out of Range REC LockOpen Drain Valve Indication Probe Failure Indication M-100B Computer Set-Up and Programming InstructionsHow to Change the Computer’s Display Language 1 M-100B Computer Setup ModeHow to Enter the Setup Mode How to Configure the Computer for Use on a Gas FryerHow to Change Computer Product/Temperature Displays How to Enter the Program Mode How to Activate or Deactivate the Frypot BOIL-OUT Feature2 M-100B Computer Programming Mode How to Reset the Computer to the Factory DefaultsHow to Change the Cooking Temperature Setpoint How to Enter a Product Name in a Test Menu How to Suppress a Shake, QA, or Duty Function How to Display Use Time Information How to Display the Product Cycle Accumulator InformationHow to Use the Filter Countdown Timer Operating Fryers With Analog Controllers Introduction to the Analog ControllerC D E F G H I J K L M N Analog Controller High-Limit Check Page Filtering Operating the Built-In Filtration System Page Operating the Filter Unit Page Getting the Most Out of Your Filter Page Preventive Maintenance Preventive Maintenance and TroubleshootingTroubleshooting Troubleshooting Fryers with M100B Computers REC LockIgnition Failure Display Remains Blank When ON/OFF Switches are Pressed Troubleshooting Fryers Equipped with Analog Controllers Did burners Troubleshooting Built-in Filtration System Pump does Not RUN