CHAPTER 5: FILTERING

5.1Draining and Manual Filtering

DANGER

Always wear appropriate protective gloves when draining or filtering.

Allow cooking oil to cool to 100ºF (38ºC) or lower before draining to an appropriate

container for disposal.

NOTE: If your fryer is not equipped with a built-in filtration system, the cooking oil must be drained into another suitable container. For safe, convenient draining and disposal of used cooking oil, Frymaster recommends using the Vegetable Oil Disposal Unit, illustrated at right.

1.Turn the fryer controller OFF. Screw the drainpipe (provided with your fryer) into the drain valve. Make sure the drainpipe is firmly screwed into the drain valve.

2.Position the Vegetable Oil Disposal Unit (or a metal container with a sealable cover) under the drainpipe. NOTE: The metal container must be able to withstand the heat of the cooking oil and hold hot liquids. If you intend to reuse the oil, Frymaster recommends that a Frymaster filter cone holder and filter cone be used when a filter machine is not available. If you are using a Frymaster filter cone holder, be sure that the cone holder rests securely on the metal container.

3.Open the drain valve slowly to avoid splattering. If the drain valve becomes clogged with food particles, use the Fryer’s Friend (poker-like tool) to clear the blockage from the frypot side.

DANGER

DO NOT insert anything into the drain from the front to unclog the valve. Hot oil will

rush out, creating an extreme hazard.

WARNING

DO NOT hammer on the drain valve with the Fryer’s Friend. This will damage the drain valve ball and prevent the valve from sealing securely, resulting in a leaky valve.

4.After draining the oil, clean all food particles and residual oil/shortening from the frypot. BE CAREFUL, this material may still cause severe burns if it comes in contact with bare skin.

5-1

Image 33
Contents OPERATOR’S Manual Frymaster H52 Series GAS Fryer Page General IntroductionComputer Information European Community CE Specific InformationWhat to do if your equipment arrives damaged Service Information General Installation Requirements Installation InstructionsNational Code Requirements Caster/Leg Installation Non-CE Standard For Incoming Gas Pressures Countries Categories GAS Connection to Gas LineCE Standard Gas Vat Converting to Another Gas TypeNon-CE Gas Conversion Kits CE Gas Conversion Kits for Units with Gas ValveFrypot Boil-Out Shutdown Operating Fryers With M100B Cooking ComputersDescription Introduction To The M-100B Cooking ComputerOperating the Computer on Full-Vat Fryers Viewing the Frypot Temperature Actual or Setpoint Operating the Computer on Split-Vat FryersCooking Product Full-Vat or Split-Vat Recovery Out of Range REC Lock M-100B Computer Problem Condition IndicatorsOpen Drain Valve Indication M-100B Computer Set-Up and Programming Instructions Probe Failure IndicationHow to Enter the Setup Mode 1 M-100B Computer Setup ModeHow to Change the Computer’s Display Language How to Configure the Computer for Use on a Gas FryerHow to Change Computer Product/Temperature Displays 2 M-100B Computer Programming Mode How to Activate or Deactivate the Frypot BOIL-OUT FeatureHow to Enter the Program Mode How to Reset the Computer to the Factory DefaultsHow to Change the Cooking Temperature Setpoint How to Enter a Product Name in a Test Menu How to Suppress a Shake, QA, or Duty Function How to Display the Product Cycle Accumulator Information How to Display Use Time InformationHow to Use the Filter Countdown Timer Introduction to the Analog Controller Operating Fryers With Analog ControllersC D E F G H I J K L M N Analog Controller High-Limit Check Page Filtering Operating the Built-In Filtration System Page Operating the Filter Unit Page Getting the Most Out of Your Filter Page Preventive Maintenance and Troubleshooting Preventive MaintenanceTroubleshooting REC Lock Troubleshooting Fryers with M100B ComputersIgnition Failure Display Remains Blank When ON/OFF Switches are Pressed Troubleshooting Fryers Equipped with Analog Controllers Did burners Troubleshooting Built-in Filtration System Pump does Not RUN