Index of error messages

Error codes

Error Codes

Error Messages

 

 

006

Equipment Configuration Error

 

Causes:

 

1. CPU BIOS Update Code Mismatch

 

2. IDE Primary Channel Master Drive Error

 

(The causes are shown before “Equipment Configuration Error”)

 

 

010

Memory Error at xxxx:xxxx:xxxxh (R:xxxxh, W:xxxxh)

 

 

070

Real Time Clock Error

 

 

071

CMOS Battery Bad

 

 

072

CMOS Checksum Error

 

 

110

System is disabled. An incorrect password was entered.

 

 

<No error code>

Battery is critically low. In this situation BIOS issues four short beeps, then

 

shuts the system down. No message is displayed.

 

 

<No error code>

Temperature is critically high. In this situation BIOS shuts the system down.

 

No message is displayed.

 

 

Error messages

Error Messages

FRU/Action Sequence

 

 

Stuck Key

See “Testing the keyboard or auxiliary input device” on

 

page 137.

 

 

Keyboard error

See “Testing the keyboard or auxiliary input device” on

 

page 137.

 

 

Keyboard Controller Failed

See “Testing the keyboard or auxiliary input device” on

 

page 137.

 

 

Keyboard locked - Unlock key switch

Unlock the external keyboard.

 

 

Monitor type does not match CMOS -

Run “Load Setup Defaults” using the BIOS Setup Utility,

Run Setup

then reboot the notebook.

 

 

Shadow RAM Failed at offset: nnnn

• Test or replace the BIOS ROM.

 

• Test or replace the system board.

 

 

System RAM Failed at offset: nnnn

• Test or replace the SO-DIMM.

 

• Test or replace the system board.

 

 

Extended RAM Failed at offset: nnnn

• Test or replace the SO-DIMM.

 

• Test or replace the system board.

 

 

System battery is dead - Replace and run

Replace the CMOS battery, run the BIOS Setup Utility to

Setup

reconfigure system time, then reboot the system.

 

 

System CMOS checksum bad - Default

Replace the CMOS battery, run the BIOS Setup Utility to

configuration used

reconfigure system time, then reboot the system.

 

 

System timer error

• Replace the CMOS battery, run the BIOS Setup Utility

 

to reconfigure system time, then reboot the system.

 

• Test or replace the system board.

 

 

Real time clock error

• Replace the CMOS battery, run the BIOS Setup Utility

 

to reconfigure system time, then reboot the system.

 

• Test or replace the system board.

 

 

Chapter 4: Troubleshooting

141

Page 151
Image 151
Acer 7730 manual Index of error messages, 141, Error codes, Error messages