No beep, power-on indicator turns off

• Test the power source (battery pack and power

and LCD is blank.

adapter). See “Testing the power system” on page 138.

 

• Make sure that every connector is connected tightly

 

and correctly.

 

• Reconnect the SO-DIMM.

 

• Test or replace the LED board.

 

• Test or replace the system board.

 

 

No beep, power-on indicator turns on

• Test the power source (battery pack and power

and LCD is blank.

adapter). See “Testing the power system” on page 138.

 

• Reconnect the LCD connector

 

• Check the hard disk drive.

 

• Check the LCD inverter ID.

 

• Check the LCD cable.

 

• Test or replace the LCD inverter.

 

• Test or replace the LCD.

 

• Test or replace the system board.

 

 

No beep, power-on indicator turns on

• Reconnect the LCD connectors.

and LCD is blank. But you can see POST

• Check the LCD inverter ID.

on an external CRT.

• Check the LCD cable.

 

• Test or replace the LCD inverter.

 

• Test or replace the LCD.

 

• Test or replace the system board.

 

 

No beep, power-on indicator turns on

• Make sure that every connector is connected tightly

and a blinking cursor shown on LCD

and correctly.

during POST.

• Test or replace the system board.

 

 

No beep during POST but system runs

• Test or replace the speaker.

correctly.

• Test or replace the system board.

 

 