Frymaster H52 Series warranty Operating the Built-In Filtration System

Page 34

5.Close the drain valve securely and fill the frypot with clean cooking oil to the bottom OIL- LEVEL line.

5.2Operating the Built-In Filtration System

The FootPrint III (FP III) filtration system allows the cooking oil in one frypot to be safely and effi- ciently filtered while the other frypots in a battery remain in operation.

Most reported problems with these systems are caused by improper operation. Careful attention to the step-by-step instructions that follow will ensure that your system operates as intended.

PREPARING THE FILTER UNIT FOR USE and CHANGING THE FILTER PAPER

1.Turn the controller OFF.

2.Pull the filter unit from the cabinet, open the cover, remove the crumb tray, and remove the paper hold-down ring.

3.If changing the filter paper after filtering, remove and discard the used paper (or op- tional filter pad). Be careful, the oil-soaked paper or pad may be very hot and can cause severe burns.

After removing the filter paper (or pad), remove the metal filter screen and pan, and clean them thoroughly with a solution of hot water and detergent. Ensure that all breading and food particles are removed from the pan.

Dry the pan thoroughly with a soft cloth or paper towels.

Allow the filter screen to dry completely, then reinstall it in the filter pan.

DANGER

Always wear appropriate protective gloves when changing the filter paper.

5-2

Image 34
Contents OPERATOR’S Manual Frymaster H52 Series GAS Fryer Page Introduction GeneralEuropean Community CE Specific Information Computer InformationWhat to do if your equipment arrives damaged Service Information Installation Instructions General Installation RequirementsNational Code Requirements Caster/Leg Installation Non-CE Standard For Incoming Gas Pressures Connection to Gas Line Countries Categories GASCE Standard Converting to Another Gas Type Gas VatCE Gas Conversion Kits for Units with Gas Valve Non-CE Gas Conversion KitsFrypot Boil-Out Operating Fryers With M100B Cooking Computers ShutdownIntroduction To The M-100B Cooking Computer DescriptionOperating the Computer on Full-Vat Fryers Operating the Computer on Split-Vat Fryers Viewing the Frypot Temperature Actual or SetpointCooking Product Full-Vat or Split-Vat M-100B Computer Problem Condition Indicators Recovery Out of Range REC LockOpen Drain Valve Indication Probe Failure Indication M-100B Computer Set-Up and Programming InstructionsHow to Change the Computer’s Display Language 1 M-100B Computer Setup ModeHow to Enter the Setup Mode How to Configure the Computer for Use on a Gas FryerHow to Change Computer Product/Temperature Displays How to Enter the Program Mode How to Activate or Deactivate the Frypot BOIL-OUT Feature2 M-100B Computer Programming Mode How to Reset the Computer to the Factory DefaultsHow to Change the Cooking Temperature Setpoint How to Enter a Product Name in a Test Menu How to Suppress a Shake, QA, or Duty Function How to Display Use Time Information How to Display the Product Cycle Accumulator InformationHow to Use the Filter Countdown Timer Operating Fryers With Analog Controllers Introduction to the Analog ControllerC D E F G H I J K L M N Analog Controller High-Limit Check Page Filtering Operating the Built-In Filtration System Page Operating the Filter Unit Page Getting the Most Out of Your Filter Page Preventive Maintenance Preventive Maintenance and TroubleshootingTroubleshooting Troubleshooting Fryers with M100B Computers REC LockIgnition Failure Display Remains Blank When ON/OFF Switches are Pressed Troubleshooting Fryers Equipped with Analog Controllers Did burners Troubleshooting Built-in Filtration System Pump does Not RUN