DISPLAY REMAINS

BLANK WHEN ON/OFF

SWITCHES ARE

PRESSED

Verify that fryer power cord is

plugged in, fryer circuit

breaker is not tripped, and exhaust hood circuit breaker is not tripped. Press ON/ OFF switch ON.

Is fryer

operating Yes Problem resolved. correctly?

No

Press ON/OFF switches OFF, Swap computer with another known to be working correctly.

Press ON/OFF switch ON.

COMPUTER WILL

NOT GO INTO

PROGRAMMING

MODE

Verify that that computer is OFF before attempting to enter programming mode.

Press the 1 and 2 buttons

on the left side, and the left arrow button simultaneously (use quick press and release).

Did computer

enter programming Yes Problem resolved. mode?

Is fryer

 

Problem is defective

operating

Yes

computer. Replace.

correctly?

 

 

No

 

 

No

 

 

 

 

If there is no difficulty

Probable causes are

 

getting other computers into

 

the programming mode, the

loose/shorted wires in

 

problem is a defective computer.

computer wiring harness

 

Replace.

or failed transformer.

 

If other computers

Call FASC.

 

 

will not enter programming

 

 

mode, the problem may be with

 

 

operator technique.

6-4

Image 43
Contents OPERATOR’S Manual Frymaster H52 Series GAS Fryer Page General IntroductionEuropean Community CE Specific Information Computer InformationWhat to do if your equipment arrives damaged Service Information General Installation Requirements Installation InstructionsNational Code Requirements Caster/Leg Installation Non-CE Standard For Incoming Gas Pressures Countries Categories GAS Connection to Gas LineCE Standard Gas Vat Converting to Another Gas TypeCE Gas Conversion Kits for Units with Gas Valve Non-CE Gas Conversion KitsFrypot Boil-Out Shutdown Operating Fryers With M100B Cooking ComputersDescription Introduction To The M-100B Cooking ComputerOperating the Computer on Full-Vat Fryers Operating the Computer on Split-Vat Fryers Viewing the Frypot Temperature Actual or SetpointCooking Product Full-Vat or Split-Vat Recovery Out of Range REC Lock M-100B Computer Problem Condition IndicatorsOpen Drain Valve Indication M-100B Computer Set-Up and Programming Instructions Probe Failure IndicationHow to Configure the Computer for Use on a Gas Fryer 1 M-100B Computer Setup ModeHow to Enter the Setup Mode How to Change the Computer’s Display LanguageHow to Change Computer Product/Temperature Displays How to Reset the Computer to the Factory Defaults How to Activate or Deactivate the Frypot BOIL-OUT Feature2 M-100B Computer Programming Mode How to Enter the Program ModeHow to Change the Cooking Temperature Setpoint How to Enter a Product Name in a Test Menu How to Suppress a Shake, QA, or Duty Function How to Display the Product Cycle Accumulator Information How to Display Use Time InformationHow to Use the Filter Countdown Timer Introduction to the Analog Controller Operating Fryers With Analog ControllersC D E F G H I J K L M N Analog Controller High-Limit Check Page Filtering Operating the Built-In Filtration System Page Operating the Filter Unit Page Getting the Most Out of Your Filter Page Preventive Maintenance Preventive Maintenance and TroubleshootingTroubleshooting REC Lock Troubleshooting Fryers with M100B ComputersIgnition Failure Display Remains Blank When ON/OFF Switches are Pressed Troubleshooting Fryers Equipped with Analog Controllers Did burners Troubleshooting Built-in Filtration System Pump does Not RUN