NOTE: You must agitate the vegetable oil with a maple paddle during the entire high-limit control- check procedure.

CAUTION

If after completing both high-limit tests you find only the second high-limit operates properly, the vat can be used if it is absolutely necessary, but with extreme care. The controller must be replaced immediately after this period of necessity. If the second high-limit does not work the vat must not be used until the second high-limit has been replaced. If the first high-limit feature activates at less than 400°F (204°C), do not replace the controller unless it interferes with proper cooking. If the second high-limit activates at less than 425°F (218°C), do not replace it unless it prevents you from checking the first high-limit feature.

4. Press and hold the vat high-limit test switch in the "first high-limit" position.

Expected Result: Gas burner turns OFF and "TROUBLE" light comes ON. Vegetable oil temperature should be between 400º and 425ºF (204º and 218ºC).

5. Press and hold the vat high-limit test switch in the "second high-limit" position.

NOTE: When the trouble light comes ON, or the temperature exceeds 425ºF (218ºC), release the switch.

Expected Result: Gas burner turns OFF and the second high-limit comes ON. The vegetable oil temperature should be between 425º and 450ºF (218º and 232ºC).

CAUTION

When the second high-limit light comes on, or the temperature exceeds 450°F (232°C),

release switch.

6.Turn the power switch to the “OFF” position. One vat must remain ON to ensure hood fan remains ON.

7.Remove the fry vat probe and reinstall the computer probe into the vat.

8.Allow vegetable oil to cool for one hour before discarding. See statement on discarding oil (Chapter 5).

NOTE: Hot oil must not be transported until it cools to 100°F (38°C) or less. High-Limit check is complete. Repeat procedure for each remaining vat.

4-4

Image 32
Contents OPERATOR’S Manual Frymaster H52 Series GAS Fryer Page Introduction GeneralWhat to do if your equipment arrives damaged Computer InformationEuropean Community CE Specific Information Service Information Installation Instructions General Installation RequirementsNational Code Requirements Caster/Leg Installation Non-CE Standard For Incoming Gas Pressures Connection to Gas Line Countries Categories GASCE Standard Converting to Another Gas Type Gas VatFrypot Boil-Out Non-CE Gas Conversion KitsCE Gas Conversion Kits for Units with Gas Valve Operating Fryers With M100B Cooking Computers ShutdownIntroduction To The M-100B Cooking Computer DescriptionOperating the Computer on Full-Vat Fryers Cooking Product Full-Vat or Split-Vat Viewing the Frypot Temperature Actual or SetpointOperating the Computer on Split-Vat Fryers M-100B Computer Problem Condition Indicators Recovery Out of Range REC LockOpen Drain Valve Indication Probe Failure Indication M-100B Computer Set-Up and Programming Instructions1 M-100B Computer Setup Mode How to Enter the Setup ModeHow to Change the Computer’s Display Language How to Configure the Computer for Use on a Gas FryerHow to Change Computer Product/Temperature Displays How to Activate or Deactivate the Frypot BOIL-OUT Feature 2 M-100B Computer Programming ModeHow to Enter the Program Mode How to Reset the Computer to the Factory DefaultsHow to Change the Cooking Temperature Setpoint How to Enter a Product Name in a Test Menu How to Suppress a Shake, QA, or Duty Function How to Display Use Time Information How to Display the Product Cycle Accumulator InformationHow to Use the Filter Countdown Timer Operating Fryers With Analog Controllers Introduction to the Analog ControllerC D E F G H I J K L M N Analog Controller High-Limit Check Page Filtering Operating the Built-In Filtration System Page Operating the Filter Unit Page Getting the Most Out of Your Filter Page Troubleshooting Preventive Maintenance and TroubleshootingPreventive Maintenance Troubleshooting Fryers with M100B Computers REC LockIgnition Failure Display Remains Blank When ON/OFF Switches are Pressed Troubleshooting Fryers Equipped with Analog Controllers Did burners Troubleshooting Built-in Filtration System Pump does Not RUN