Open Drain Valve Indication

If, when the ON/OFF switch is pressed to the ON position, the display reads IGNITION FAILURE, verify that the drain valve is fully closed. A drain safety switch built into the drain valve assembly prevents the coil of the gas valve(s) from being energized if the drain valve is not completely closed. After verifying that the valve is fully closed, turn the computer OFF* for at least 5 seconds, then turn it back on. If the message reappears, there is a problem in the electrical circuitry of the fryer or the computer. Contact your Frymaster Factory Authorized Service Center (FASC).

*On early-version M-100B split-vat units, BOTH computers must be turned off, even though the problem condition may be associated with only one vat.

Low Temperature Indication

If the frypot temperature drops to more than 45°F (25°C) below the programmed setpoint temperature during the cooking cycle, the cook switches will lock, the display will flash lOW TEMP and an

audible alarm will sound. If the frypot temperature returns to a range between 45°F (25°C) to 15°F (8°C) of setpoint, the audible alarm will stop, but the cook switches remain locked and the display

3–6

Image 19
Contents OPERATOR’S Manual Frymaster H52 Series GAS Fryer Page General IntroductionEuropean Community CE Specific Information Computer InformationWhat to do if your equipment arrives damaged Service Information General Installation Requirements Installation InstructionsNational Code Requirements Caster/Leg Installation Non-CE Standard For Incoming Gas Pressures Countries Categories GAS Connection to Gas LineCE Standard Gas Vat Converting to Another Gas TypeCE Gas Conversion Kits for Units with Gas Valve Non-CE Gas Conversion KitsFrypot Boil-Out Shutdown Operating Fryers With M100B Cooking ComputersDescription Introduction To The M-100B Cooking ComputerOperating the Computer on Full-Vat Fryers Operating the Computer on Split-Vat Fryers Viewing the Frypot Temperature Actual or SetpointCooking Product Full-Vat or Split-Vat Recovery Out of Range REC Lock M-100B Computer Problem Condition IndicatorsOpen Drain Valve Indication M-100B Computer Set-Up and Programming Instructions Probe Failure IndicationHow to Configure the Computer for Use on a Gas Fryer 1 M-100B Computer Setup ModeHow to Enter the Setup Mode How to Change the Computer’s Display LanguageHow to Change Computer Product/Temperature Displays How to Reset the Computer to the Factory Defaults How to Activate or Deactivate the Frypot BOIL-OUT Feature2 M-100B Computer Programming Mode How to Enter the Program ModeHow to Change the Cooking Temperature Setpoint How to Enter a Product Name in a Test Menu How to Suppress a Shake, QA, or Duty Function How to Display the Product Cycle Accumulator Information How to Display Use Time InformationHow to Use the Filter Countdown Timer Introduction to the Analog Controller Operating Fryers With Analog ControllersC D E F G H I J K L M N Analog Controller High-Limit Check Page Filtering Operating the Built-In Filtration System Page Operating the Filter Unit Page Getting the Most Out of Your Filter Page Preventive Maintenance Preventive Maintenance and TroubleshootingTroubleshooting REC Lock Troubleshooting Fryers with M100B ComputersIgnition Failure Display Remains Blank When ON/OFF Switches are Pressed Troubleshooting Fryers Equipped with Analog Controllers Did burners Troubleshooting Built-in Filtration System Pump does Not RUN