Frymaster H52 Series warranty How to Use the Filter Countdown Timer

Page 28

How to Use the Filter Countdown Timer

NOTE: This feature starts a five-minute countdown timer to time the polishing of vegetable oil during the filtering process. Polishing refers to circulating the vegetable oil through the filtration system for a specified time. This feature does not have any direct control over the filtration process; it is only a timer.

1.With the computer ON, press and release the switch until FILTER appears in the display. (For split-vat units, press and release the switch for the left vat.)

2.Press either of the right 1 or 2 switches. The computer will begin to countdown from five minutes to zero. (For split-vat units, press either of the left 1 or 2 switches for the left vat.)

3–15

Image 28
Contents OPERATOR’S Manual Frymaster H52 Series GAS Fryer Page Introduction GeneralEuropean Community CE Specific Information Computer InformationWhat to do if your equipment arrives damaged Service Information Installation Instructions General Installation RequirementsNational Code Requirements Caster/Leg Installation Non-CE Standard For Incoming Gas Pressures Connection to Gas Line Countries Categories GASCE Standard Converting to Another Gas Type Gas VatCE Gas Conversion Kits for Units with Gas Valve Non-CE Gas Conversion KitsFrypot Boil-Out Operating Fryers With M100B Cooking Computers ShutdownIntroduction To The M-100B Cooking Computer DescriptionOperating the Computer on Full-Vat Fryers Operating the Computer on Split-Vat Fryers Viewing the Frypot Temperature Actual or SetpointCooking Product Full-Vat or Split-Vat M-100B Computer Problem Condition Indicators Recovery Out of Range REC LockOpen Drain Valve Indication Probe Failure Indication M-100B Computer Set-Up and Programming Instructions1 M-100B Computer Setup Mode How to Enter the Setup ModeHow to Change the Computer’s Display Language How to Configure the Computer for Use on a Gas FryerHow to Change Computer Product/Temperature Displays How to Activate or Deactivate the Frypot BOIL-OUT Feature 2 M-100B Computer Programming ModeHow to Enter the Program Mode How to Reset the Computer to the Factory DefaultsHow to Change the Cooking Temperature Setpoint How to Enter a Product Name in a Test Menu How to Suppress a Shake, QA, or Duty Function How to Display Use Time Information How to Display the Product Cycle Accumulator InformationHow to Use the Filter Countdown Timer Operating Fryers With Analog Controllers Introduction to the Analog ControllerC D E F G H I J K L M N Analog Controller High-Limit Check Page Filtering Operating the Built-In Filtration System Page Operating the Filter Unit Page Getting the Most Out of Your Filter Page Preventive Maintenance Preventive Maintenance and TroubleshootingTroubleshooting Troubleshooting Fryers with M100B Computers REC LockIgnition Failure Display Remains Blank When ON/OFF Switches are Pressed Troubleshooting Fryers Equipped with Analog Controllers Did burners Troubleshooting Built-in Filtration System Pump does Not RUN