Frymaster H52 Series warranty Troubleshooting Fryers with M100B Computers, REC Lock

Page 41

6.2.1 Troubleshooting Fryers with M100B Computers

DISPLAY SHOWS

REC LOCK

Clear REC LOCK condition (see Page 3-5) and resume cooking. Avoid adding cooking oil to the frypot between the time the fryer is turned on and the time it reaches the programmed cooking temperature.

If REC LOCK occurs 3 or

more times within one week and cooking oil is NOT being added to the frypot while the heat mode indicator is illuminated, there is a problem with the fryer.

Call FASC.

RECOVERY TIME IS

SLOW, BUT OTHERWISE

FRYER IS OPERATING

CORRECTLY

Clean combustion

air blowers and resume cooking.

Is recovery

Yes

Problem resolved.

time correct?

 

 

No

Probable causes are

low burner gas pressure,

or undersized or

obstructed burner orifices.

Call FASC.

6-2

Image 41
Contents OPERATOR’S Manual Frymaster H52 Series GAS Fryer Page General IntroductionWhat to do if your equipment arrives damaged Computer InformationEuropean Community CE Specific Information Service Information General Installation Requirements Installation InstructionsNational Code Requirements Caster/Leg Installation Non-CE Standard For Incoming Gas Pressures Countries Categories GAS Connection to Gas LineCE Standard Gas Vat Converting to Another Gas TypeFrypot Boil-Out Non-CE Gas Conversion KitsCE Gas Conversion Kits for Units with Gas Valve Shutdown Operating Fryers With M100B Cooking ComputersDescription Introduction To The M-100B Cooking ComputerOperating the Computer on Full-Vat Fryers Cooking Product Full-Vat or Split-Vat Viewing the Frypot Temperature Actual or SetpointOperating the Computer on Split-Vat Fryers Recovery Out of Range REC Lock M-100B Computer Problem Condition IndicatorsOpen Drain Valve Indication M-100B Computer Set-Up and Programming Instructions Probe Failure IndicationHow to Enter the Setup Mode 1 M-100B Computer Setup ModeHow to Change the Computer’s Display Language How to Configure the Computer for Use on a Gas FryerHow to Change Computer Product/Temperature Displays 2 M-100B Computer Programming Mode How to Activate or Deactivate the Frypot BOIL-OUT FeatureHow to Enter the Program Mode How to Reset the Computer to the Factory DefaultsHow to Change the Cooking Temperature Setpoint How to Enter a Product Name in a Test Menu How to Suppress a Shake, QA, or Duty Function How to Display the Product Cycle Accumulator Information How to Display Use Time InformationHow to Use the Filter Countdown Timer Introduction to the Analog Controller Operating Fryers With Analog ControllersC D E F G H I J K L M N Analog Controller High-Limit Check Page Filtering Operating the Built-In Filtration System Page Operating the Filter Unit Page Getting the Most Out of Your Filter Page Troubleshooting Preventive Maintenance and TroubleshootingPreventive Maintenance REC Lock Troubleshooting Fryers with M100B ComputersIgnition Failure Display Remains Blank When ON/OFF Switches are Pressed Troubleshooting Fryers Equipped with Analog Controllers Did burners Troubleshooting Built-in Filtration System Pump does Not RUN