Frymaster H52 Series warranty Operating Fryers With M100B Cooking Computers, Shutdown

Page 14

CHAPTER 3: OPERATING FRYERS

WITH M100B™ COOKING COMPUTERS

3.1Equipment Setup and Shutdown Procedures

Setup

WARNING

Fill the frypot to the bottom oil level line with vegetable oil before pressing the ON/OFF switch to the ON position. Failure to do so could damage the frypot.

1.Fill the frypot with vegetable oil to the bottom OIL LEVEL line located on the rear of the frypot. This will allow for oil expansion as heat is applied. Do not fill cold oil any higher than the bottom line; overflow may occur as heat expands the oil.

2.Ensure that the power cord(s) is/are plugged into the appropriate receptacle(s). Verify that the face of the plug is flush with the outlet plate, with no portion of the prongs visible.

3.Ensure that the vegetable oil level is at the top OIL LEVEL line when the vegetable oil is at its programmed cooking temperature. It may be necessary to add vegetable oil to bring the level up to the proper mark, after the oil has reached the programmed cooking temperature.

CAUTION

Do not add vegetable oil to the fryer between the time the computer is turned on and the time it reaches programmed cooking temperature. Doing so is likely to cause RECOVERY LOCKOUT (REC LOCK). See Section 3.4.

Shutdown

1.Press the ON/OFF switch to the OFF position (the display will show OFF).

2.Filter vegetable oil and clean fryers.

3.Place the frypot covers on frypots.

3.2 Finding Information

How do I…

Page

How do I…

Page

Activate/deactivate the BOIL-OUT mode?

3-10

Display “use time” information?

3-14

Change computer product/temp displays?

3-9

Enter a product number in a test menu?

3-12

Change cooking temperature setpoint?

3-11

Enter the program mode?

3-8

Calibrate computer to frypot temperature?

3-9

Enter the setup mode?

3-8

Change shake, pull, or quality times?

3-10

Program test item parameters?

3-12

Change the display language?

3-8

Reset the computer to factory defaults?

3-10

Configure the computer for a gas fryer?

3-8

Suppress a shake, QA, or duty function?

3-13

Configure the computer for full- or split-vat?

3-9

Turn factory-programmed menu item on/off?

3-14

Display Product Cycle Accumulator info?

3-14

Use the filter countdown time?

3-15

3–1

Image 14
Contents OPERATOR’S Manual Frymaster H52 Series GAS Fryer Page Introduction GeneralWhat to do if your equipment arrives damaged Computer InformationEuropean Community CE Specific Information Service Information Installation Instructions General Installation RequirementsNational Code Requirements Caster/Leg Installation Non-CE Standard For Incoming Gas Pressures Connection to Gas Line Countries Categories GASCE Standard Converting to Another Gas Type Gas VatFrypot Boil-Out Non-CE Gas Conversion KitsCE Gas Conversion Kits for Units with Gas Valve Operating Fryers With M100B Cooking Computers ShutdownIntroduction To The M-100B Cooking Computer DescriptionOperating the Computer on Full-Vat Fryers Cooking Product Full-Vat or Split-Vat Viewing the Frypot Temperature Actual or SetpointOperating the Computer on Split-Vat Fryers M-100B Computer Problem Condition Indicators Recovery Out of Range REC LockOpen Drain Valve Indication Probe Failure Indication M-100B Computer Set-Up and Programming InstructionsHow to Change the Computer’s Display Language 1 M-100B Computer Setup ModeHow to Enter the Setup Mode How to Configure the Computer for Use on a Gas FryerHow to Change Computer Product/Temperature Displays How to Enter the Program Mode How to Activate or Deactivate the Frypot BOIL-OUT Feature2 M-100B Computer Programming Mode How to Reset the Computer to the Factory DefaultsHow to Change the Cooking Temperature Setpoint How to Enter a Product Name in a Test Menu How to Suppress a Shake, QA, or Duty Function How to Display Use Time Information How to Display the Product Cycle Accumulator InformationHow to Use the Filter Countdown Timer Operating Fryers With Analog Controllers Introduction to the Analog ControllerC D E F G H I J K L M N Analog Controller High-Limit Check Page Filtering Operating the Built-In Filtration System Page Operating the Filter Unit Page Getting the Most Out of Your Filter Page Troubleshooting Preventive Maintenance and TroubleshootingPreventive Maintenance Troubleshooting Fryers with M100B Computers REC LockIgnition Failure Display Remains Blank When ON/OFF Switches are Pressed Troubleshooting Fryers Equipped with Analog Controllers Did burners Troubleshooting Built-in Filtration System Pump does Not RUN