Frymaster H52 Series warranty Operating the Computer on Split-Vat Fryers

Page 17

Once the frypot temperature is above 180°F (82°C), but still 15°F (8°C) or more below the setpoint temperature for the product displayed (for example, french fries), the computer will alternately display

LOW TEMP and FR FRIES, and the right heating mode indicator will remain continuously illuminated.

The cooking cycle cannot be started until the cooking oil is within ±15°F (8°C) of the programmed setpoint. When the frypot temperature is within ±15°F (8°C) of the programmed setpoint, the product name will be displayed continuously, indicating that the fryer is ready to cook the displayed product.

Operating the Computer on Split-Vat Fryers

1.Turn ON the cooking computer by pressing the ON/OFF switches . Pressing the left switch turns on the left side of the computer; pressing the right switch turns on the right side. A product name (for example, FR FRIES) will appear in the LED display corresponding to the switch pressed.

2.If the frypot temperature is below 180°F (82°C), the computer will automatically enter a warm-up cycle (often called a melt cycle). The burners will cycle on and off repeatedly, allowing the vegetable oil to heat gradually, without scorching. During the warm-up cycle, the heating mode indicator will alternately illuminate and go out as the burners cycle on and off. Within 45 minutes, the computer will exit the warm-up cycle and the heat mode indicator will remain continuously illuminated.

3.Select the product to be cooked by pressing the left or right product selection switches , depending upon the vat in which you wish to cook.

4.Once the frypot temperature is above 180°F (82°C), but still 15°F (8°C) or more below the setpoint temperature for the product displayed (for example, french fries), the computer will alternately display LOW TEMP and FR FRIES, and the heating mode indicator will remain continuously illuminated.

5.The cooking cycle cannot be started until the cooking oil is within ±15°F (8°C) of the programmed setpoint. When the frypot temperature is within ±15°F (8°C) of the programmed setpoint, the product name will be displayed continuously, indicating that the fryer is ready to cook the displayed product.

Viewing the Frypot Temperature (Actual or Setpoint)

To display the actual frypot temperature, press the temperature check switch once. To display the setpoint temperature, press the switch twice.

Cooking Product (Full-Vat or Split-Vat)

1.Fill basket(s) with product, lower the basket into the vegetable oil, then press the cook switch ( 1 or 2 ) that corresponds to the full- or split-vat to be used. This will activate the cooking cycle of the product.

3–4

Image 17
Contents OPERATOR’S Manual Frymaster H52 Series GAS Fryer Page General IntroductionWhat to do if your equipment arrives damaged Computer InformationEuropean Community CE Specific Information Service Information General Installation Requirements Installation InstructionsNational Code Requirements Caster/Leg Installation Non-CE Standard For Incoming Gas Pressures Countries Categories GAS Connection to Gas LineCE Standard Gas Vat Converting to Another Gas TypeFrypot Boil-Out Non-CE Gas Conversion KitsCE Gas Conversion Kits for Units with Gas Valve Shutdown Operating Fryers With M100B Cooking ComputersDescription Introduction To The M-100B Cooking ComputerOperating the Computer on Full-Vat Fryers Cooking Product Full-Vat or Split-Vat Viewing the Frypot Temperature Actual or SetpointOperating the Computer on Split-Vat Fryers Recovery Out of Range REC Lock M-100B Computer Problem Condition IndicatorsOpen Drain Valve Indication M-100B Computer Set-Up and Programming Instructions Probe Failure IndicationHow to Enter the Setup Mode 1 M-100B Computer Setup ModeHow to Change the Computer’s Display Language How to Configure the Computer for Use on a Gas FryerHow to Change Computer Product/Temperature Displays 2 M-100B Computer Programming Mode How to Activate or Deactivate the Frypot BOIL-OUT FeatureHow to Enter the Program Mode How to Reset the Computer to the Factory DefaultsHow to Change the Cooking Temperature Setpoint How to Enter a Product Name in a Test Menu How to Suppress a Shake, QA, or Duty Function How to Display the Product Cycle Accumulator Information How to Display Use Time InformationHow to Use the Filter Countdown Timer Introduction to the Analog Controller Operating Fryers With Analog ControllersC D E F G H I J K L M N Analog Controller High-Limit Check Page Filtering Operating the Built-In Filtration System Page Operating the Filter Unit Page Getting the Most Out of Your Filter Page Troubleshooting Preventive Maintenance and TroubleshootingPreventive Maintenance REC Lock Troubleshooting Fryers with M100B ComputersIgnition Failure Display Remains Blank When ON/OFF Switches are Pressed Troubleshooting Fryers Equipped with Analog Controllers Did burners Troubleshooting Built-in Filtration System Pump does Not RUN