Frymaster H52 Series warranty Ignition Failure

Page 42

DISPLAY SHOWS

IGNITION FAILURE,

ALARM IS SOUNDING,

AND BURNERS WILL

NOT LIGHT

Verify that all drain

valves are fully

closed, the main gas valve is open and the gas valves on the fryer are on.

Press ON/OFF switch

OFF (on Split Vat

units, both switches must be OFF). Press ON/OFF switch ON.

Is fryer

operating Yes Problem resolved. correctly?

No

Probable causes are a

defective or misaligned drain

safety switch or an open

high-limit thermostat.

Call FASC.

DISPLAY SHOWS

IGNITION FAILURE,

ALARM IS SOUNDING,

BUT BURNERS LIGHT

Press ON/OFF switch OFF

(on Split Vat units, both switches must be OFF).

Swap computer with another

known to be working

correctly. Press ON/OFF

switch ON.

 

 

False alarm. Install

 

 

computer on another

Is fryer

 

fryer and test operation.

Yes

If problem repeats,

operating

computer is defective and

correctly?

 

must be replaced. If not,

 

 

problem should be

 

 

investigated by

No

 

FASC.

 

 

Probable cause is a

defective ignition module.

Call FASC.

6-3

Image 42
Contents OPERATOR’S Manual Frymaster H52 Series GAS Fryer Page Introduction GeneralComputer Information European Community CE Specific InformationWhat to do if your equipment arrives damaged Service Information Installation Instructions General Installation RequirementsNational Code Requirements Caster/Leg Installation Non-CE Standard For Incoming Gas Pressures Connection to Gas Line Countries Categories GASCE Standard Converting to Another Gas Type Gas VatNon-CE Gas Conversion Kits CE Gas Conversion Kits for Units with Gas ValveFrypot Boil-Out Operating Fryers With M100B Cooking Computers ShutdownIntroduction To The M-100B Cooking Computer DescriptionOperating the Computer on Full-Vat Fryers Viewing the Frypot Temperature Actual or Setpoint Operating the Computer on Split-Vat FryersCooking Product Full-Vat or Split-Vat M-100B Computer Problem Condition Indicators Recovery Out of Range REC LockOpen Drain Valve Indication Probe Failure Indication M-100B Computer Set-Up and Programming InstructionsHow to Change the Computer’s Display Language 1 M-100B Computer Setup ModeHow to Enter the Setup Mode How to Configure the Computer for Use on a Gas FryerHow to Change Computer Product/Temperature Displays How to Enter the Program Mode How to Activate or Deactivate the Frypot BOIL-OUT Feature2 M-100B Computer Programming Mode How to Reset the Computer to the Factory DefaultsHow to Change the Cooking Temperature Setpoint How to Enter a Product Name in a Test Menu How to Suppress a Shake, QA, or Duty Function How to Display Use Time Information How to Display the Product Cycle Accumulator InformationHow to Use the Filter Countdown Timer Operating Fryers With Analog Controllers Introduction to the Analog ControllerC D E F G H I J K L M N Analog Controller High-Limit Check Page Filtering Operating the Built-In Filtration System Page Operating the Filter Unit Page Getting the Most Out of Your Filter Page Preventive Maintenance and Troubleshooting Preventive MaintenanceTroubleshooting Troubleshooting Fryers with M100B Computers REC LockIgnition Failure Display Remains Blank When ON/OFF Switches are Pressed Troubleshooting Fryers Equipped with Analog Controllers Did burners Troubleshooting Built-in Filtration System Pump does Not RUN