Frymaster H52 Series warranty

Page 37

2.After all oil has drained from the pot, rotate the Rear Flush handle to the ON position to activate the pump. There may be a slight delay before the pump activates.

3.As the filtering progresses, the computer will display the time remaining. When the filtering time has elapsed, FILTER will flash in the display.

4.When FILTER flashes in the display, close the drain valve and allow the frypot to refill.

5.When the filter pan has emptied, bubbles will appear in the frypot. Allow the bubbling to continue 15-20 seconds to purge all cooking oil from the oil return lines, then rotate the Rear Flush handle to the OFF position to stop the pump.

5-5

Image 37
Contents OPERATOR’S Manual Frymaster H52 Series GAS Fryer Page General IntroductionEuropean Community CE Specific Information Computer InformationWhat to do if your equipment arrives damaged Service Information General Installation Requirements Installation InstructionsNational Code Requirements Caster/Leg Installation Non-CE Standard For Incoming Gas Pressures Countries Categories GAS Connection to Gas LineCE Standard Gas Vat Converting to Another Gas TypeCE Gas Conversion Kits for Units with Gas Valve Non-CE Gas Conversion KitsFrypot Boil-Out Shutdown Operating Fryers With M100B Cooking ComputersDescription Introduction To The M-100B Cooking ComputerOperating the Computer on Full-Vat Fryers Operating the Computer on Split-Vat Fryers Viewing the Frypot Temperature Actual or SetpointCooking Product Full-Vat or Split-Vat Recovery Out of Range REC Lock M-100B Computer Problem Condition IndicatorsOpen Drain Valve Indication M-100B Computer Set-Up and Programming Instructions Probe Failure IndicationHow to Enter the Setup Mode 1 M-100B Computer Setup ModeHow to Change the Computer’s Display Language How to Configure the Computer for Use on a Gas FryerHow to Change Computer Product/Temperature Displays 2 M-100B Computer Programming Mode How to Activate or Deactivate the Frypot BOIL-OUT FeatureHow to Enter the Program Mode How to Reset the Computer to the Factory DefaultsHow to Change the Cooking Temperature Setpoint How to Enter a Product Name in a Test Menu How to Suppress a Shake, QA, or Duty Function How to Display the Product Cycle Accumulator Information How to Display Use Time InformationHow to Use the Filter Countdown Timer Introduction to the Analog Controller Operating Fryers With Analog ControllersC D E F G H I J K L M N Analog Controller High-Limit Check Page Filtering Operating the Built-In Filtration System Page Operating the Filter Unit Page Getting the Most Out of Your Filter Page Preventive Maintenance Preventive Maintenance and TroubleshootingTroubleshooting REC Lock Troubleshooting Fryers with M100B ComputersIgnition Failure Display Remains Blank When ON/OFF Switches are Pressed Troubleshooting Fryers Equipped with Analog Controllers Did burners Troubleshooting Built-in Filtration System Pump does Not RUN