BURNERS DO NOT
LIGHT
(POWER LIGHT ON,
HEAT LIGHT ON,
TROUBLE LIGHT ON)
Verify that all drain valves are fully closed. Verify the main gas valve is open and the gas valve knob (non- CE units) is ON. Place power swtiches in OFF position, then back ON.
Did burners | Yes | Problem resolved. | |
light? | |||
|
|
No
Place power switches in OFF
position. Disconnect and reconnect the flexible gas line
Did burners | Yes | Problem resolved. | |
light? | |||
|
|
No
Place power switches in OFF
position. Verify that combustion air blower inlet is open and that blower is clean. Place power switches in ON position.
No |
|
| |
Did burners | Yes | Problem resolved. | |
light? | |||
|
|
No
Problem is beyond scope of operator troubleshooting. Call
FASC
FRYER FAILS 2ND
(HEAT LIGHT ON, 2ND
Probable cause is a defective high-
limit thermostat. Call FASC.