PRODUCT IDENTIFICATION

 

MBR/MBE Air Handlers

Model #

Description

 

 

MBR****AA-1AA

Modular Blower R Multi-Position PSC Motor. Introduces module blower with PSC

blower motor.

 

 

 

MBE****AA-1AA

Modular Blower E Multi-Position Variable-Speed. Introduces module blower with

variable speed blower motor.

 

 

 

MBE****AA-1BA

Modular Blower E Multi-Position Variable-Speed.Revision introduces new models

adding lower kw hit kits on the S&R plate

 

 

 

 

Evaporator Coils

Model #

 

 

Description

 

 

 

 

CAUF*****6AA

C Indoor Coil A Upflow/Downflow Uncased Flowrator. Introduces 13 SEER CAUF

 

 

 

Dayton Upflow/Downflow coils.

 

 

 

CAUF*****6BA

C Indoor Coil A Upflow/Downflow Uncased Flowrator. Revision releases Burr Oak

 

 

 

Louvered Fin in place of the Wavy Fin currently in production.

 

 

 

CAPF*****6AA

C Indoor Coil A Upflow/Downflow Painted Flowrator. Introduces 13 SEER CAPF

 

 

 

Dayton Upflow/Downflow coils.

 

 

 

CAPF*****6BA

C Indoor Coil A Upflow/Downflow Painted Flowrator. Revision releases Burr Oak

 

 

 

Louvered Fin in place of the Wavy Fin currently in production.

 

 

 

CAPF/CAUF36***CA

C Indoor Coil A Upflow/Downflow [Painted or Uncased] Flowrator. Revision

 

 

 

redesigns for performance improvement from 2 row to 3 row.

 

 

 

CHPF*****6AA

C Indoor Coil Horizontal A Coil Painted Flowrator. Release 13 SEER CHPF

horizontal A coil.

 

 

 

 

C Indoor Coil Horizontal A Coil Painted Flowrator. Release 13 SEER CHPF

CHPF*****6BA

horizontal A coil. Revision releases Burr Oak Louvered Fin in place of the Wavy

Fin currently in production. The rows change by one, (i.e. 4 row to 3 row; 3 row to

 

 

2 row) where applicable.

 

 

 

 

CHPF2430B6CA

C Indoor Coil Horizontal A Coil Painted Flowrator. 13 SEER CHPF horizontal A

CHPF3636B6CA

CHPF3642[C-D]6CA

coil, revision has louver fins & replaces copper tube hairpins with aluminum

CHPF3743C6BA

hairpins.

CHPF3743D6CA

 

 

 

CSCF*****6AA

C Indoor Coil S Horizontal Slab Coil C Upainted Flowrator. Release 13 SEER

CSCF slab horizontal coil.

 

 

 

CSCF*****6BA

C Indoor Coil S Horizontal Slab Coil C Upainted Flowrator. Revision releases Burr

Oak Louvered Fin in place of the Wavy Fin currently in production. The rows

 

change by one, (i.e. 4 row to 3 row; 3 row to 2 row) where applicable.

 

 

 

 

10

Image 10
Contents Service Instructions Important Information Recognize Safety SYMBOLS, Words and LabelsEmail us at customerservice@goodmanmfg.com Fax us at 713 Fax us at 931 438Safe Refrigerant Handling Product Identification Split System Heat Pumps R410AModel # Description Split System Air Conditioners R410A ASX130**1AA Single Piece Air Handlers AWUF****1AA MBR/MBE Air Handlers Product Identification 1824 3642 Accessories ASX13DSX/SSX16 ASX18 ASZ13 DSZ/SSZ16 ASZ18 Expansion Valve Kits FSK01A Coil Accessories Electric Heat Kitapplications Aruf Electric Heat Kitapplications Aepf Product Design Condensing UnitFigure a Capacity Control Cooling System OperationHeating Cooling CycleDefrost Cycle Heating CycleCooling Cycle System Operation AFE18-60A Control Board DescriptionTroubleshooting Chart COOLING/HP Analysis ChartServicing 61B3A Thermostat and Wiring Checking WiringChecking THERMOSTAT, WIRING, and Anticipator Checking Voltage3B Cooling Anticipator 3C Heating AnticipatorChecking Transformer Control Circuit Checking Time Delay RelayTesting Coil Circuit Checking Cycle ProtectorChecking Contactor AND/OR Relays Testing Compressor ContactorSingle Phase Checking Contactor ContactsCopeland Comfort Alert Diagnostics Testing FAN RelayDiagnostics Table Checking LOW Pressure Control Checking Loss of Charge ProtectorChecking High Pressure Control Checking Capacitor15B Capacitance Check 15A Resistance CheckRELAY, Start 16A Checking FAN and Blower Motor Windings PSC Motors 16B Checking FAN and Blower Motor ECM MotorsChart on Next Chart from Previous 16D ECM CFM Adjustments MBE / Aepf 16C Checking ECM Motor WindingsCFM 16F Checking GE X13TM Motors 16E Blower Performance DataGE X13TM Motor Connections 17A Resistance Test Testing Compressor WindingsChecking Compressor 17B Ground Test17D Operation Test 17C Unloader Test ProcedureUnloader Test Procedure Compressor Ground TestTesting Defrost Thermostat Testing Crankcase Heater Optional ItemTesting Defrost Control Checking Reversing Valve and SolenoidChecking Heater Elements 40 MBR/AR*F Electronic Blower Time Delay RelayChecking Heater Limit Controls Sequence of OperationMBR/AR*F with Single Stage Heat Pumps Heating OperationDefrost Operation 41 MBE/AEPF with GSX, SSX, ASX, DSXMBE/AEPF with Single Stage GSX, ASX and SSX Condensers 41A MBE/AEPF with Single Stage GSZ, SSZ, & ASZ Heat Pumps Sequence of Operation MBE/AEPF with TWO Stage ASX & DSX CondensersMBE/AEPF with TWO Stage ASZ & DSZ Heat Pump Units Electric Heater Optional Item 61B Checking Heater Fuse Link Optional Electric Heaters 61A Checking Heater Limit ControlsFormulas Evacuation Leak Testing Nitrogen or NITROGEN-TRACEDRefrigeration Repair Practice Brazing MaterialsCharging EvacuationFinal Charge Adjustment Checking Compressor Efficiency105B Thermostatic Expansion Valve TXV ValvesPressure vs. Temperature Chart 410A Required Liquid Line Temperature Superheat OverfeedingUnderfeeding Checking SubcoolingFixed Orifice Restrictor Devices 109A TWO Speed ApplicationChecking Expansion Valve Operation Subcooling Formula = Sat. Liquid Temp. Liquid LineNON-CONDENSABLES Checking Restricted Liquid LineOvercharge of Refrigerant Compressor BurnoutLong Line SET Application R-410A Accessories for lines greater than 80 feetRefrigerant Piping Tube SizingInstallation Requirements AIR Handler External Static Initial System ChargingTotal External Static Coil Static Pressure DropStatic Pressure Drop Accessories Wiring Diagrams ALL Fuel System AFE18-60A Control Board10kw and Below, One Stage Electric Heat OT/EHR18-60 #2 GRD PLM PLF XFMR-R XFMR-C After Installing Optional Heat KIT, Mark AN X Provided Above HKR Heat Kit GRD PLM PLF