Goodmans DSX, GSZ, ASZ, SSX, ASX, DSZ, GSX, SSZ manual 3642

Page 13

PRODUCT IDENTIFICATION

A

W

U

F

 

 

 

EXPANSION

PRODUCT

 

 

DEVICE:

TYPE:

 

 

F: Flowrater

A: Air Handler

 

 

T: TXV

 

 

 

(Expansion

 

 

 

 

Device)

 

 

 

 

 

 

 

 

 

 

 

CABINET FINISH:

 

U:Unpainted

P:Paited

N:Uncased

APPLICATION

3642

1

6

A

A

MINOR

REVISION*

MAJOR

REVISION*

REFRIGERANT CHARGE:

No Digit: R-22 Only

6:R-410A or R-22

C:Ceiling Mount PSC Motor

D:Downflow PSC Motor

E:Multi-Position Varible-Speed Motor

S:Energy-Efficient Motor

R:Multi-Position PSC Motor

T:Coated Coils

W:Wall Mount PSC Motor

ELECTRICAL:

1: 208-230V/1ph/60Hz

NOMINAL CAPACITY RANGE:

@13 SEER Dedicated Application 3636: 3 Tons

Multi-Position & Downflow Applications 3137: 3 Tons

3642: 3 - 3 1/2 Tons

1830: 1 1/2 - 3 1/2 Tons @10 SEER

1729: 1 1/2 - 2 1/2 Tons (for export systems)

Ceiling Mount & Wall Mount Applications

(Nominal Cooling Capacity/Electric Heat kW)

1805: 1 1/2 Tons Cooling / 5 kW Electric Heat

2405: 2 Tons Cooling / 5 kW Electric Heat

3608: 3 Tons Cooling / 8 kW Electric Heat

3705: 3 Tons Cooling / 5 kW Electric Heat

3708: 3 Tons Cooling / 8 kW Electric Heat

All Airhandlers use DIRECT DRIVE MOTORS. Power supply is AC 208-230v, 60 hz, 1 phase.

13

Image 13
Contents Service Instructions Email us at customerservice@goodmanmfg.com Recognize Safety SYMBOLS, Words and LabelsImportant Information Fax us at 713 Fax us at 931 438Safe Refrigerant Handling Split System Heat Pumps R410A Product IdentificationModel # Description Split System Air Conditioners R410A ASX130**1AA Single Piece Air Handlers AWUF****1AA MBR/MBE Air Handlers Product Identification 1824 3642 ASX13 AccessoriesDSX/SSX16 ASX18 ASZ13 DSZ/SSZ16 ASZ18 Expansion Valve Kits FSK01A Coil Accessories Electric Heat Kitapplications Aruf Electric Heat Kitapplications Aepf Condensing Unit Product DesignFigure a Capacity Control Heating System OperationCooling Cooling CycleHeating Cycle Defrost CycleCooling Cycle System Operation Description AFE18-60A Control BoardCOOLING/HP Analysis Chart Troubleshooting Chart61B ServicingChecking THERMOSTAT, WIRING, and Anticipator Checking Wiring3A Thermostat and Wiring Checking Voltage3C Heating Anticipator 3B Cooling AnticipatorTesting Coil Circuit Checking Time Delay RelayChecking Transformer Control Circuit Checking Cycle ProtectorSingle Phase Testing Compressor ContactorChecking Contactor AND/OR Relays Checking Contactor ContactsTesting FAN Relay Copeland Comfort Alert DiagnosticsDiagnostics Table Checking High Pressure Control Checking Loss of Charge ProtectorChecking LOW Pressure Control Checking Capacitor15B Capacitance Check 15A Resistance CheckRELAY, Start 16B Checking FAN and Blower Motor ECM Motors 16A Checking FAN and Blower Motor Windings PSC MotorsChart on Next Chart from Previous 16C Checking ECM Motor Windings 16D ECM CFM Adjustments MBE / AepfCFM 16F Checking GE X13TM Motors 16E Blower Performance DataGE X13TM Motor Connections Checking Compressor Testing Compressor Windings17A Resistance Test 17B Ground TestUnloader Test Procedure 17C Unloader Test Procedure17D Operation Test Compressor Ground TestTesting Defrost Control Testing Crankcase Heater Optional ItemTesting Defrost Thermostat Checking Reversing Valve and SolenoidChecking Heater Limit Controls 40 MBR/AR*F Electronic Blower Time Delay RelayChecking Heater Elements Sequence of OperationHeating Operation MBR/AR*F with Single Stage Heat PumpsDefrost Operation 41 MBE/AEPF with GSX, SSX, ASX, DSXMBE/AEPF with Single Stage GSX, ASX and SSX Condensers 41A MBE/AEPF with Single Stage GSZ, SSZ, & ASZ Heat Pumps MBE/AEPF with TWO Stage ASX & DSX Condensers Sequence of OperationMBE/AEPF with TWO Stage ASZ & DSZ Heat Pump Units Electric Heater Optional Item 61B Checking Heater Fuse Link Optional Electric Heaters 61A Checking Heater Limit ControlsFormulas Refrigeration Repair Practice Leak Testing Nitrogen or NITROGEN-TRACEDEvacuation Brazing MaterialsEvacuation ChargingChecking Compressor Efficiency Final Charge AdjustmentTXV Valves 105B Thermostatic Expansion ValvePressure vs. Temperature Chart 410A Required Liquid Line Temperature Underfeeding OverfeedingSuperheat Checking SubcoolingChecking Expansion Valve Operation 109A TWO Speed ApplicationFixed Orifice Restrictor Devices Subcooling Formula = Sat. Liquid Temp. Liquid LineOvercharge of Refrigerant Checking Restricted Liquid LineNON-CONDENSABLES Compressor BurnoutRefrigerant Piping Accessories for lines greater than 80 feetLong Line SET Application R-410A Tube SizingInstallation Requirements Initial System Charging AIR Handler External StaticTotal External Static Coil Static Pressure DropStatic Pressure Drop ALL Fuel System AFE18-60A Control Board Accessories Wiring Diagrams10kw and Below, One Stage Electric Heat OT/EHR18-60 #2 GRD PLM PLF XFMR-R XFMR-C After Installing Optional Heat KIT, Mark AN X Provided Above HKR Heat Kit GRD PLM PLF