Goodmans SSZ, GSZ, ASZ, SSX, DSZ, DSX, GSX manual ASX130**1AA

Page 7

PRODUCT IDENTIFICATION

 

Split System Air Conditioners R410A

 

 

Model #

Description

 

 

ASX130**1AA

Amana® Brand Split X Condenser 13 Seer condensing units. Initial release new models

of Amana® Brand Deluxe 13 SEER AC R410A conditioners.

 

 

 

ASX130**1BA

Amana® Brand Split X Condenser 13 Seer condensing units. Introduction of Amana®

Brand 13 SEER R-410A Condensers, using Quantum Leap Coils. Units will have new

 

louvers since units are smaller. Piston size change; other components unchanged.

 

 

ASX140**1AA

Amana® Brand Split X Condenser 14 Seer condensing units. Initial release new models

of Amana® Brand Deluxe 14 SEER AC R410A conditioners.

 

ASX140**1AB

Amana® Brand Split X Condenser 14 Seer condensing units. New revisions have

screw locations moved in the top panel, base pans, louvers, and control box covers.

 

 

 

ASX140**1AC

Amana® Brand Split X Condenser 14 Seer condensing units. The new revisions have

horizontal style louvers.

 

 

 

ASX14018-361AD

Amana® Brand Split X Condenser 14 Seer condensing units. Revised condenser coils

by removing (1) hairpin.Reduce R410A quantity by 6 ounces

 

 

 

ASX140421AD

Amana® Brand Split X Condenser 14 Seer condensing units. Introduces ASX140421A

in 29" base pan

 

 

 

ASX140421BA

Amana® Brand Split X Condenser 14 Seer condensing units. Revision for ASX140421

in 29" platform. It will the reduce the unit charge from 180 oz. to 170 oz. and replace the

 

1/4 hp outdoor unit motor with 1/6 hp motor.

ASX140[18-36]1BA

Amana® Brand Split X Condenser 14 Seer condensing units. Introduction of Amana®

ASX140421CA

Brand 14 SEER R-410A Condensers, using Quantum Leap Coils.

 

 

ASX160**1AB

Amana® Brand Split X Condenser 16 Seer condensing units. New revisions have

screw locations moved in the top panel, base pans, louvers, and control box covers.

 

 

 

ASX160**1AC

Amana® Brand Split X Condenser 16 Seer condensing units. The new revisions have

horizontal style louvers.

 

 

 

ASX180**1AB

Amana® Brand Split X Condenser 18 Seer condensing units. Initial release new models

of Amana® Brand Deluxe 16 SEER AC R410A conditioners.

 

7

Image 7
Contents Service Instructions Fax us at 713 Fax us at 931 438 Recognize Safety SYMBOLS, Words and LabelsEmail us at customerservice@goodmanmfg.com Important InformationSafe Refrigerant Handling Split System Heat Pumps R410A Product IdentificationModel # Description Split System Air Conditioners R410A ASX130**1AA Single Piece Air Handlers AWUF****1AA MBR/MBE Air Handlers Product Identification 1824 3642 ASX13 AccessoriesDSX/SSX16 ASX18 ASZ13 DSZ/SSZ16 ASZ18 Expansion Valve Kits FSK01A Coil Accessories Electric Heat Kitapplications Aruf Electric Heat Kitapplications Aepf Condensing Unit Product DesignFigure a Capacity Control Cooling Cycle System OperationHeating CoolingHeating Cycle Defrost CycleCooling Cycle System Operation Description AFE18-60A Control BoardCOOLING/HP Analysis Chart Troubleshooting Chart61B ServicingChecking Voltage Checking WiringChecking THERMOSTAT, WIRING, and Anticipator 3A Thermostat and Wiring3C Heating Anticipator 3B Cooling AnticipatorChecking Cycle Protector Checking Time Delay RelayTesting Coil Circuit Checking Transformer Control CircuitChecking Contactor Contacts Testing Compressor ContactorSingle Phase Checking Contactor AND/OR RelaysTesting FAN Relay Copeland Comfort Alert DiagnosticsDiagnostics Table Checking Capacitor Checking Loss of Charge ProtectorChecking High Pressure Control Checking LOW Pressure Control15B Capacitance Check 15A Resistance CheckRELAY, Start 16B Checking FAN and Blower Motor ECM Motors 16A Checking FAN and Blower Motor Windings PSC MotorsChart on Next Chart from Previous 16C Checking ECM Motor Windings 16D ECM CFM Adjustments MBE / AepfCFM 16F Checking GE X13TM Motors 16E Blower Performance DataGE X13TM Motor Connections 17B Ground Test Testing Compressor WindingsChecking Compressor 17A Resistance TestCompressor Ground Test 17C Unloader Test ProcedureUnloader Test Procedure 17D Operation TestChecking Reversing Valve and Solenoid Testing Crankcase Heater Optional ItemTesting Defrost Control Testing Defrost ThermostatSequence of Operation 40 MBR/AR*F Electronic Blower Time Delay RelayChecking Heater Limit Controls Checking Heater ElementsHeating Operation MBR/AR*F with Single Stage Heat PumpsDefrost Operation 41 MBE/AEPF with GSX, SSX, ASX, DSXMBE/AEPF with Single Stage GSX, ASX and SSX Condensers 41A MBE/AEPF with Single Stage GSZ, SSZ, & ASZ Heat Pumps MBE/AEPF with TWO Stage ASX & DSX Condensers Sequence of OperationMBE/AEPF with TWO Stage ASZ & DSZ Heat Pump Units Electric Heater Optional Item 61B Checking Heater Fuse Link Optional Electric Heaters 61A Checking Heater Limit ControlsFormulas Brazing Materials Leak Testing Nitrogen or NITROGEN-TRACEDRefrigeration Repair Practice EvacuationEvacuation ChargingChecking Compressor Efficiency Final Charge AdjustmentTXV Valves 105B Thermostatic Expansion ValvePressure vs. Temperature Chart 410A Required Liquid Line Temperature Checking Subcooling OverfeedingUnderfeeding SuperheatSubcooling Formula = Sat. Liquid Temp. Liquid Line 109A TWO Speed ApplicationChecking Expansion Valve Operation Fixed Orifice Restrictor DevicesCompressor Burnout Checking Restricted Liquid LineOvercharge of Refrigerant NON-CONDENSABLESTube Sizing Accessories for lines greater than 80 feetRefrigerant Piping Long Line SET Application R-410AInstallation Requirements Initial System Charging AIR Handler External StaticTotal External Static Coil Static Pressure DropStatic Pressure Drop ALL Fuel System AFE18-60A Control Board Accessories Wiring Diagrams10kw and Below, One Stage Electric Heat OT/EHR18-60 #2 GRD PLM PLF XFMR-R XFMR-C After Installing Optional Heat KIT, Mark AN X Provided Above HKR Heat Kit GRD PLM PLF